Time-efficiency and cost-analysis comparing three digital workflows for treatment with monolithic zirconia implant fixed dental prostheses: A double-blinded RCT. (October 2021)
- Record Type:
- Journal Article
- Title:
- Time-efficiency and cost-analysis comparing three digital workflows for treatment with monolithic zirconia implant fixed dental prostheses: A double-blinded RCT. (October 2021)
- Main Title:
- Time-efficiency and cost-analysis comparing three digital workflows for treatment with monolithic zirconia implant fixed dental prostheses: A double-blinded RCT
- Authors:
- Joda, Tim
Gintaute, Aiste
Brägger, Urs
Ferrari, Marco
Weber, Karin
Zitzmann, Nicola U. - Abstract:
- Abstract: Objectives: This double-blinded randomized controlled trial investigated economic performance indicators (EPI) in terms of time-efficiency and production costs of 3-unit monolithic zirconium-dioxide (ZrO2) implant fixed dental prostheses (iFDP) in three different workflows. Methods: Twenty patients with two Straumann Tissue-Level-Implants received three iFDPs; two were fabricated in proprietary complete digital workflows with intraoral optical scanning and model-free fabrication with company-related CAD/CAM lab-software while one iFDP was manufactured on digitized casts from conventional impressions. The sequence of impression-taking for the three workflows (TRIOS 3/3Shape [Test-1]; Virtuo Vivo/Dental Wings [Test-2]; Impregum/3M Espe [Control]) was randomly allocated. Sixty iFDPs bonded to ti-base abutments were analyzed. Clinical and technical worksteps for Test-1/Test-2/Control were recorded and evaluated for time-efficiency including cost-analysis (CHF=Swiss Francs) using ANOVA-Tests (significance level α=0.05). Results: Mean total work time, as the sum of clinical plus technical steps, was 97.5 min (SD ± 23.6) for Test-1, 193.1 min (SD ± 25.2) for Test-2, and 172.6 min (SD ± 27.4) for Control. Times were significantly different between Test-1/Test-2 ( p < 0.00001), Test-1/Control ( p < 0.00001), and Test-2/Control ( p < 0.03610). Technical costs were 566 CHF (SD ± 49.3) for Test-1, 711 CHF (SD ± 78.8) for Test-2, 812 CHF (SD ± 89.6) for Control, and wereAbstract: Objectives: This double-blinded randomized controlled trial investigated economic performance indicators (EPI) in terms of time-efficiency and production costs of 3-unit monolithic zirconium-dioxide (ZrO2) implant fixed dental prostheses (iFDP) in three different workflows. Methods: Twenty patients with two Straumann Tissue-Level-Implants received three iFDPs; two were fabricated in proprietary complete digital workflows with intraoral optical scanning and model-free fabrication with company-related CAD/CAM lab-software while one iFDP was manufactured on digitized casts from conventional impressions. The sequence of impression-taking for the three workflows (TRIOS 3/3Shape [Test-1]; Virtuo Vivo/Dental Wings [Test-2]; Impregum/3M Espe [Control]) was randomly allocated. Sixty iFDPs bonded to ti-base abutments were analyzed. Clinical and technical worksteps for Test-1/Test-2/Control were recorded and evaluated for time-efficiency including cost-analysis (CHF=Swiss Francs) using ANOVA-Tests (significance level α=0.05). Results: Mean total work time, as the sum of clinical plus technical steps, was 97.5 min (SD ± 23.6) for Test-1, 193.1 min (SD ± 25.2) for Test-2, and 172.6 min (SD ± 27.4) for Control. Times were significantly different between Test-1/Test-2 ( p < 0.00001), Test-1/Control ( p < 0.00001), and Test-2/Control ( p < 0.03610). Technical costs were 566 CHF (SD ± 49.3) for Test-1, 711 CHF (SD ± 78.8) for Test-2, 812 CHF (SD ± 89.6) for Control, and were also significantly different for all comparisons ( p < 0.00001). Conclusions: Test-1 demonstrated the best performance for time-efficiency, Test-2 revealed the worst result. This indicates that digital workflows are not the same and not necessarily superior to analog workflows of monolithic ZrO2 iFDPs. Complexity decreases by reducing the number of steps following complete digital workflows, resulting in lower production costs compared to the mixed analog-digital workflow with conventional impressions. Clinical significance: Complete digital workflows comprising intraoral optical scanning without physical models for treatment with monolithic ZrO2 iFDPs is an efficient alternative to mixed analog-digital workflows with conventional impressions and labside digitization of dental casts. … (more)
- Is Part Of:
- Journal of dentistry. Volume 113(2021)
- Journal:
- Journal of dentistry
- Issue:
- Volume 113(2021)
- Issue Display:
- Volume 113, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 113
- Issue:
- 2021
- Issue Sort Value:
- 2021-0113-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10
- Subjects:
- Clinical research -- Dental implant -- Fixed dental prosthesis (FDP) -- Digital dentistry -- Economic performance indicator (EPI) -- Economics
Dentistry -- Periodicals
Dentistry -- Periodicals
Dentisterie -- Périodiques
Electronic journals
617.6005 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03005712 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03005712 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jdent.2021.103779 ↗
- Languages:
- English
- ISSNs:
- 0300-5712
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4968.670000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19861.xml