Utility of hybrid PET/MRI multiparametric imaging in navigating SEEG placement in refractory epilepsy. (October 2020)
- Record Type:
- Journal Article
- Title:
- Utility of hybrid PET/MRI multiparametric imaging in navigating SEEG placement in refractory epilepsy. (October 2020)
- Main Title:
- Utility of hybrid PET/MRI multiparametric imaging in navigating SEEG placement in refractory epilepsy
- Authors:
- Zhang, Miao
Liu, Wei
Huang, Peng
Lin, Xiaozhu
Huang, Xinyun
Meng, Hongping
Wang, Jin
Hu, Kejia
Li, Jian
Lin, Mu
Sun, Bomin
Zhan, Shikun
Li, Biao - Abstract:
- Highlights: Hybrid PET/MRI is a new technology combined metabolism and morphological imaging. Hybrid PET/MRI increase precisely localizing seizure onset zone (SOZ) in epilepsy. Hybrid PET/MRI optimize SEEG electrode placement. Concordant of PET/MRI and SEEG SOZ location demonstrates favorable surgery outcome. Abstract: Purpose: Stereo-electroencephalography (SEEG) implantation before epilepsy surgery is critical for precise localization and complete resection of the seizure onset zone (SOZ). Combined metabolic and morphological imaging using hybrid PET/MRI may provide supportive information for the optimization of the SEEG coverage of brain structures. In this study, we originally imported PET/MRI images into the SEEG positioning system to evaluate the application of PET/MRI in guiding SEEG implantation in refractory epilepsy patients. Materials: Forty-two patients undergoing simultaneous PET/MRI examinations were recruited. All the patients underwent SEEG implantation guided by hybrid PET/MRI and surgical resection or ablation of epileptic lesion. Surgery outcome was assessed using a modified Engel classification one year (13.60 ± 2.49 months) after surgery. Areas of SOZ were identified using hybrid PET/MRI and concordance with SEEG was evaluated. Logistic regression analysis was used to predict the presence of a favorable outcome with the coherence of concordance of PET/MRI and SEEG. Results: Hybrid PET/MRI (including visual PET, MRI, plus MI Neuro) identified SOZ lesionsHighlights: Hybrid PET/MRI is a new technology combined metabolism and morphological imaging. Hybrid PET/MRI increase precisely localizing seizure onset zone (SOZ) in epilepsy. Hybrid PET/MRI optimize SEEG electrode placement. Concordant of PET/MRI and SEEG SOZ location demonstrates favorable surgery outcome. Abstract: Purpose: Stereo-electroencephalography (SEEG) implantation before epilepsy surgery is critical for precise localization and complete resection of the seizure onset zone (SOZ). Combined metabolic and morphological imaging using hybrid PET/MRI may provide supportive information for the optimization of the SEEG coverage of brain structures. In this study, we originally imported PET/MRI images into the SEEG positioning system to evaluate the application of PET/MRI in guiding SEEG implantation in refractory epilepsy patients. Materials: Forty-two patients undergoing simultaneous PET/MRI examinations were recruited. All the patients underwent SEEG implantation guided by hybrid PET/MRI and surgical resection or ablation of epileptic lesion. Surgery outcome was assessed using a modified Engel classification one year (13.60 ± 2.49 months) after surgery. Areas of SOZ were identified using hybrid PET/MRI and concordance with SEEG was evaluated. Logistic regression analysis was used to predict the presence of a favorable outcome with the coherence of concordance of PET/MRI and SEEG. Results: Hybrid PET/MRI (including visual PET, MRI, plus MI Neuro) identified SOZ lesions in 38 epilepsy patients (90.47 %). PET/MRI showed the same SOZ localization with SEEG in 29 patients (69.05 %), which was considered to be concordant. The concordance between the PET/MRI and SEEG findings was significantly predictive of a successful surgery outcome (odds ratio = 20.41; 95 % CI = 2.75–151.4, P = 0.003**). Conclusion: Hybrid PET/MRI combined visual PET, multiple sequences MRI and SPM PET helps identify epilepsy lesions particularly in subtle hypometabolic areas. Patients with concordant epileptic lesion localization on PET/MRI and SEEG demonstrated a more favorable outcome than those with inconsistent localization between modalities. … (more)
- Is Part Of:
- Seizure. Volume 81(2020)
- Journal:
- Seizure
- Issue:
- Volume 81(2020)
- Issue Display:
- Volume 81, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 81
- Issue:
- 2020
- Issue Sort Value:
- 2020-0081-2020-0000
- Page Start:
- 295
- Page End:
- 303
- Publication Date:
- 2020-10
- Subjects:
- Hybrid PET/MRI -- Epilepsy -- Seizure onset zone (SOZ) -- Stereo-Electroencephalography (SEEG) -- Surgical outcome
Epilepsy -- Periodicals
Epilepsy -- Periodicals
Seizures -- Periodicals
Épilepsie -- Périodiques
Electronic journals
Electronic journals
616.853 - Journal URLs:
- http://www.seizure-journal.com/ ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13550306 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10591311 ↗
http://www.sciencedirect.com/science/journal/10591311 ↗
http://www.elsevier.com/journals ↗
http://www.harcourt-international.com/journals/seiz/ ↗ - DOI:
- 10.1016/j.seizure.2020.08.027 ↗
- Languages:
- English
- ISSNs:
- 1059-1311
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8229.100000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19715.xml