Pre‐analytical variables in haemostasis: Findings from the United Kingdom National External Quality Assessment scheme for Blood Coagulation (UK NEQAS BC) haemolysis exercise. (19th February 2021)
- Record Type:
- Journal Article
- Title:
- Pre‐analytical variables in haemostasis: Findings from the United Kingdom National External Quality Assessment scheme for Blood Coagulation (UK NEQAS BC) haemolysis exercise. (19th February 2021)
- Main Title:
- Pre‐analytical variables in haemostasis: Findings from the United Kingdom National External Quality Assessment scheme for Blood Coagulation (UK NEQAS BC) haemolysis exercise
- Authors:
- Brown, Lilia
Jennings, Ian
Kitchen, Steve
Kitchen, Dianne P.
Woods, Tim A. L.
Walker, Isobel D. - Abstract:
- Abstract: Introduction: Haemolysis is considered one of the major contributors of nonconformities and sample rejection in coagulation testing. Materials and methods: Two lyophilized plasmas were distributed to 800 centres registered for prothrombin time (PT), activated partial thromboplastin time (APTT) and either Clauss fibrinogen or thrombin time (TT) in the UK NEQAS BC programme. The same pool of normal plasma was used to prepare both samples, to one of which red blood cell haemolysate was added to mimic haemolysis at 3 g/L haemoglobin concentration. Participants were asked to complete a questionnaire about their laboratory approach to dealing with haemolysed samples, including strategies used to deal with different levels of haemolysis. Results: Results for tests performed did not show great differences between the two samples. It should be noted that artificially constructed haemolysed samples may not behave in the same way as patient samples (ie, may not be commutable). However, the possibility of carrying out a large multicentre study for detection of haemolysis was demonstrated. Inconsistency in practice was observed with 226/551 (41%) of centres indicated they reject haemolysed samples solely on visual checks, and 163 (30%) using initial visual checks with further sample rejection evaluation by analyser flags. Furthermore, 333 (72%) of centres indicated that the level of haemolysis affects sample rejection decisions, while 132 (28%) stated it did not. Conclusion:Abstract: Introduction: Haemolysis is considered one of the major contributors of nonconformities and sample rejection in coagulation testing. Materials and methods: Two lyophilized plasmas were distributed to 800 centres registered for prothrombin time (PT), activated partial thromboplastin time (APTT) and either Clauss fibrinogen or thrombin time (TT) in the UK NEQAS BC programme. The same pool of normal plasma was used to prepare both samples, to one of which red blood cell haemolysate was added to mimic haemolysis at 3 g/L haemoglobin concentration. Participants were asked to complete a questionnaire about their laboratory approach to dealing with haemolysed samples, including strategies used to deal with different levels of haemolysis. Results: Results for tests performed did not show great differences between the two samples. It should be noted that artificially constructed haemolysed samples may not behave in the same way as patient samples (ie, may not be commutable). However, the possibility of carrying out a large multicentre study for detection of haemolysis was demonstrated. Inconsistency in practice was observed with 226/551 (41%) of centres indicated they reject haemolysed samples solely on visual checks, and 163 (30%) using initial visual checks with further sample rejection evaluation by analyser flags. Furthermore, 333 (72%) of centres indicated that the level of haemolysis affects sample rejection decisions, while 132 (28%) stated it did not. Conclusion: Variability of responses for dealing with haemolysed samples reflects a lack of clear consistency in the pre‐analytical area of sample processing. … (more)
- Is Part Of:
- International journal of laboratory hematology. Volume 43:Number 5(2021)
- Journal:
- International journal of laboratory hematology
- Issue:
- Volume 43:Number 5(2021)
- Issue Display:
- Volume 43, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 43
- Issue:
- 5
- Issue Sort Value:
- 2021-0043-0005-0000
- Page Start:
- 1198
- Page End:
- 1206
- Publication Date:
- 2021-02-19
- Subjects:
- haemolysis -- haemostasis -- pre‐analytical variables -- quality
Hematology -- Periodicals
Blood -- Diseases -- Periodicals
Hematology -- Periodicals
616.15005 - Journal URLs:
- http://firstsearch.oclc.org/FSIP?db=ECO&journal=1751-5521&screen=info&done=referer ↗
http://www.blackwell-synergy.com/loi/clh ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1751-553X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ijlh.13468 ↗
- Languages:
- English
- ISSNs:
- 1751-5521
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.312220
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File: