Mid-Term Outcomes Following Percutaneous Pulmonary Valve Implantation Using the "Folded Melody Valve" Technique. (April 2021)
- Record Type:
- Journal Article
- Title:
- Mid-Term Outcomes Following Percutaneous Pulmonary Valve Implantation Using the "Folded Melody Valve" Technique. (April 2021)
- Main Title:
- Mid-Term Outcomes Following Percutaneous Pulmonary Valve Implantation Using the "Folded Melody Valve" Technique
- Authors:
- Jalal, Zakaria
Valdeolmillos, Estíbaliz
Malekzadeh-Milani, Sophie
Eicken, Andreas
Georgiev, Stanimir
Hofbeck, Michael
Sieverding, Ludger
Gewillig, Marc
Ovaert, Caroline
Bouvaist, Helene
Pillois, Xavier
Thambo, Jean-Benoit
Boudjemline, Younes - Abstract:
- Abstract : Background: The folded valve is a manual shortening of the Melody device, which has been validated as a valuable therapeutic option for the management of dysfunctional right ventricular outflow tracts needing a short valved stent. In this article, we aimed to evaluate, in a multicenter cohort, the mid-term outcomes of patients in whom a percutaneous pulmonary valve implantation was performed using the folded valve technique. Methods: A 2012 to 2018 retrospective multicenter study was performed in 7 European institutions. All patients who benefit from percutaneous pulmonary valve implantation with a folded Melody valve were included. Results: A total of 49 patients (median age, 19 years [range 4–56], 63% male) were included. The primary percutaneous pulmonary valve implantation indication was right ventricular outflow tract stenosis (n=19; 39%), patched native right ventricular outflow tracts were the most common substrate (n=15; 31%). The folded technique was mostly used in short right ventricular outflow tracts (n=28; 57%). Procedural success was 100%. After a median follow-up of 28 months (range, 4–80), folded Melody valve function was comparable to the immediate postimplantation period (mean transvalvular peak velocity=2.6±0.6 versus 2.4±0.6 m/s, P >0.1; only 2 patients had mild pulmonary regurgitation). Incidence rate of valve-related reinterventions was 2.1% per person per year (95% CI, 0.1%–3.9%). The probability of survival without valve-relatedAbstract : Background: The folded valve is a manual shortening of the Melody device, which has been validated as a valuable therapeutic option for the management of dysfunctional right ventricular outflow tracts needing a short valved stent. In this article, we aimed to evaluate, in a multicenter cohort, the mid-term outcomes of patients in whom a percutaneous pulmonary valve implantation was performed using the folded valve technique. Methods: A 2012 to 2018 retrospective multicenter study was performed in 7 European institutions. All patients who benefit from percutaneous pulmonary valve implantation with a folded Melody valve were included. Results: A total of 49 patients (median age, 19 years [range 4–56], 63% male) were included. The primary percutaneous pulmonary valve implantation indication was right ventricular outflow tract stenosis (n=19; 39%), patched native right ventricular outflow tracts were the most common substrate (n=15; 31%). The folded technique was mostly used in short right ventricular outflow tracts (n=28; 57%). Procedural success was 100%. After a median follow-up of 28 months (range, 4–80), folded Melody valve function was comparable to the immediate postimplantation period (mean transvalvular peak velocity=2.6±0.6 versus 2.4±0.6 m/s, P >0.1; only 2 patients had mild pulmonary regurgitation). Incidence rate of valve-related reinterventions was 2.1% per person per year (95% CI, 0.1%–3.9%). The probability of survival without valve-related reinterventions at 36 months was 90% (95% CI, 76%–100%). Conclusions: The folded Melody valve is a safe technique with favorable mid-term outcomes up to 6.5 years after implantation, comparable with the usual Melody valve implantation procedure. Complications and reinterventions rates were low, making this technique relevant in selected patients. … (more)
- Is Part Of:
- Circulation. Volume 14:Number 4(2021)
- Journal:
- Circulation
- Issue:
- Volume 14:Number 4(2021)
- Issue Display:
- Volume 14, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 14
- Issue:
- 4
- Issue Sort Value:
- 2021-0014-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-04
- Subjects:
- incidence -- probability -- pulmonary valve -- retrospective -- stent
Cardiovascular system -- Surgery -- Periodicals
Cardiovascular system -- Diseases -- Treatment -- Periodicals
616.105 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=01337495-000000000-00000 ↗
http://circinterventions.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCINTERVENTIONS.120.009707 ↗
- Languages:
- English
- ISSNs:
- 1941-7640
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262560
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18959.xml