Single-View Echocardiography by Nonexpert Practitioners to Detect Rheumatic Heart Disease: A Prospective Study of Diagnostic Accuracy. (August 2021)
- Record Type:
- Journal Article
- Title:
- Single-View Echocardiography by Nonexpert Practitioners to Detect Rheumatic Heart Disease: A Prospective Study of Diagnostic Accuracy. (August 2021)
- Main Title:
- Single-View Echocardiography by Nonexpert Practitioners to Detect Rheumatic Heart Disease
- Authors:
- Francis, Joshua R.
Whalley, Gillian A.
Kaethner, Alex
Fairhurst, Helen
Hardefeldt, Hilary
Reeves, Benjamin
Auld, Benjamin
Marangou, James
Horton, Ari
Wheaton, Gavin
Robertson, Terry
Ryan, Chelsea
Brown, Shannon
Smith, Greg
dos Santos, Januario
Flavio, Ricardo
Embaum, Karolina
da Graca Noronha, Mario
Lopes Belo, Sonia
Madeira Santos, Carla
Georginha dos Santos, Maria
Cabral, Jose
do Rosario, Ivonia
Harries, Jessica
Francis, Laura A.
Draper, Anthony D.K.
James, Christian L.
Davis, Kimberly
Yan, Jennifer
Mitchell, Alice
da Silva Almeida, Ines
Engelman, Daniel
Roberts, Kathryn V.
Ralph, Anna P.
Remenyi, Bo
… (more) - Abstract:
- Abstract : Background: Echocardiographic screening can detect asymptomatic cases of rheumatic heart disease (RHD), facilitating access to treatment. Barriers to implementation of echocardiographic screening include the requirement for expensive equipment and expert practitioners. We aimed to evaluate the diagnostic accuracy of an abbreviated echocardiographic screening protocol (single parasternal-long-axis view with a sweep of the heart) performed by briefly trained, nonexpert practitioners using handheld ultrasound devices. Methods: Participants aged 5 to 20 years in Timor-Leste and the Northern Territory of Australia had 2 echocardiograms: one performed by an expert echocardiographer using a GE Vivid I or Vivid Q portable ultrasound device (reference test), and one performed by a nonexpert practitioner using a GE Vscan handheld ultrasound device (index test). The accuracy of the index test, compared with the reference test, for identifying cases with definite or borderline RHD was determined. Results: There were 3111 enrolled participants; 2573 had both an index test and reference test. Median age was 12 years (interquartile range, 10–15); 58.2% were female. Proportion with definite or borderline RHD was 5.52% (95% CI, 4.70–6.47); proportion with definite RHD was 3.23% (95% CI, 2.61–3.98). Compared with the reference test, sensitivity of the index test for definite or borderline RHD was 70.4% (95% CI, 62.2–77.8), specificity was 78.1% (95% CI, 76.4–79.8). Conclusions:Abstract : Background: Echocardiographic screening can detect asymptomatic cases of rheumatic heart disease (RHD), facilitating access to treatment. Barriers to implementation of echocardiographic screening include the requirement for expensive equipment and expert practitioners. We aimed to evaluate the diagnostic accuracy of an abbreviated echocardiographic screening protocol (single parasternal-long-axis view with a sweep of the heart) performed by briefly trained, nonexpert practitioners using handheld ultrasound devices. Methods: Participants aged 5 to 20 years in Timor-Leste and the Northern Territory of Australia had 2 echocardiograms: one performed by an expert echocardiographer using a GE Vivid I or Vivid Q portable ultrasound device (reference test), and one performed by a nonexpert practitioner using a GE Vscan handheld ultrasound device (index test). The accuracy of the index test, compared with the reference test, for identifying cases with definite or borderline RHD was determined. Results: There were 3111 enrolled participants; 2573 had both an index test and reference test. Median age was 12 years (interquartile range, 10–15); 58.2% were female. Proportion with definite or borderline RHD was 5.52% (95% CI, 4.70–6.47); proportion with definite RHD was 3.23% (95% CI, 2.61–3.98). Compared with the reference test, sensitivity of the index test for definite or borderline RHD was 70.4% (95% CI, 62.2–77.8), specificity was 78.1% (95% CI, 76.4–79.8). Conclusions: Nonexpert practitioners can be trained to perform single parasternal-long-axis view with a sweep of the heart echocardiography. However, the specificity and sensitivity are inadequate for echocardiographic screening. Improved training for nonexpert practitioners should be investigated. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 14:Number 8(2021)
- Journal:
- Circulation
- Issue:
- Volume 14:Number 8(2021)
- Issue Display:
- Volume 14, Issue 8 (2021)
- Year:
- 2021
- Volume:
- 14
- Issue:
- 8
- Issue Sort Value:
- 2021-0014-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-08
- Subjects:
- echocardiography -- rheumatic heart disease -- screening
Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.1075405 - Journal URLs:
- http://circimaging.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCIMAGING.120.011790 ↗
- Languages:
- English
- ISSNs:
- 1941-9651
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262750
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18969.xml