A Dual-Platform Point-of-Care Test for Neurosyphilis Diagnosis. Issue 5 (May 2021)
- Record Type:
- Journal Article
- Title:
- A Dual-Platform Point-of-Care Test for Neurosyphilis Diagnosis. Issue 5 (May 2021)
- Main Title:
- A Dual-Platform Point-of-Care Test for Neurosyphilis Diagnosis
- Authors:
- Gonzalez, Hemil
Koralnik, Igor Jerome
Huhn, Gregory D.
Tantalo, Lauren C.
Ritz, Ethan M.
Orban, Zachary
Marra, Christina M. - Abstract:
- Abstract : Background: The diagnosis of neurosyphilis relies on cerebrospinal fluid (CSF) abnormalities (pleocytosis, elevated protein) and CSF–Venereal Disease Research Laboratory (VDRL) test. In resource-limited settings, the CSF-VDRL test may not be widely available. Methods: We optimized a commercial immunochromatographic strip test, the DPP Chembio syphilis assay, for performance with CSF and tested centrifuged CSF samples of 71 patients with syphilis (35 with neurosyphilis and 36 without neurosyphilis). A CSF dilution of 1:4 was chosen based on agreement with CSF pools with documented results from the CSF-VDRL test and fluorescent treponemal antibody absorption test on CSF. Using an electronic reader, we obtained unit values of treponemal and nontreponemal antibodies for all study samples and generated a receiver operating characteristic curve; using the Youden index, we established diagnostic cutoffs with optimal sensitivity and specificity. Results: Diagnostic sensitivity of the nontreponemal test was 80% (95% confidence interval, 63%–92%) and specificity was 97% (95% confidence interval, 85%–100%) for neurosyphilis diagnosis using a reactive CSF-VDRL that improved after neurosyphilis therapy as a criterion standard. Conclusions: In this small study, the DPP Chembio test showed promising results for neurosyphilis diagnosis. Further studies are needed to assess its performance in resource-limited settings. Abstract : We optimized the DPP Chembio syphilis assay onAbstract : Background: The diagnosis of neurosyphilis relies on cerebrospinal fluid (CSF) abnormalities (pleocytosis, elevated protein) and CSF–Venereal Disease Research Laboratory (VDRL) test. In resource-limited settings, the CSF-VDRL test may not be widely available. Methods: We optimized a commercial immunochromatographic strip test, the DPP Chembio syphilis assay, for performance with CSF and tested centrifuged CSF samples of 71 patients with syphilis (35 with neurosyphilis and 36 without neurosyphilis). A CSF dilution of 1:4 was chosen based on agreement with CSF pools with documented results from the CSF-VDRL test and fluorescent treponemal antibody absorption test on CSF. Using an electronic reader, we obtained unit values of treponemal and nontreponemal antibodies for all study samples and generated a receiver operating characteristic curve; using the Youden index, we established diagnostic cutoffs with optimal sensitivity and specificity. Results: Diagnostic sensitivity of the nontreponemal test was 80% (95% confidence interval, 63%–92%) and specificity was 97% (95% confidence interval, 85%–100%) for neurosyphilis diagnosis using a reactive CSF-VDRL that improved after neurosyphilis therapy as a criterion standard. Conclusions: In this small study, the DPP Chembio test showed promising results for neurosyphilis diagnosis. Further studies are needed to assess its performance in resource-limited settings. Abstract : We optimized the DPP Chembio syphilis assay on cerebrospinal fluid for the diagnosis of neurosyphilis and found that this point-of-care test has a diagnostic performance that is similar to a clinicoserological definition of neurosyphilis.Supplemental digital content is available in the text. … (more)
- Is Part Of:
- Sexually transmitted diseases. Volume 48:Issue 5(2021)
- Journal:
- Sexually transmitted diseases
- Issue:
- Volume 48:Issue 5(2021)
- Issue Display:
- Volume 48, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 48
- Issue:
- 5
- Issue Sort Value:
- 2021-0048-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-05
- Subjects:
- Sexually transmitted diseases -- Periodicals
Sexual health -- Periodicals
616.951005 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00007435-000000000-00000 ↗
http://www.stdjournal.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/OLQ.0000000000001308 ↗
- Languages:
- English
- ISSNs:
- 0148-5717
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8254.486500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18970.xml