Dosing Tissue Plasminogen Activator on a Mobile Stroke Unit: Comparison Between Estimated and Hospital-Measured Weights. Issue 4 (August 2021)
- Record Type:
- Journal Article
- Title:
- Dosing Tissue Plasminogen Activator on a Mobile Stroke Unit: Comparison Between Estimated and Hospital-Measured Weights. Issue 4 (August 2021)
- Main Title:
- Dosing Tissue Plasminogen Activator on a Mobile Stroke Unit
- Authors:
- Jacob, Asha P.
Wang, Mengxi
Okpala, Munachi
Yamal, Jose-Miguel
Grotta, James C.
Parker, Stephanie A. - Abstract:
- Abstract : ABSTRACT: BACKGROUND: Prehospital tissue plasminogen activator dosing in a mobile stroke unit (MSU) is estimated by the paramedic and nurse. We aimed to determine the accuracy of the estimated weight method compared with the actual weight of patients treated with tissue plasminogen activator on the MSU. METHODS: We prospectively collected the estimated weight used on the MSU for treatment and the first-documented hospital-measured weight (bed scale) within 24 hours of hospital arrival. Median absolute and percent difference in weights were calculated; less than 10% of difference in weights was considered acceptable. To compare the estimated and measured weights, we conducted a Wilcoxon signed rank test and Fisher exact test to explore the association between weight difference of greater than 10% and patient outcomes. RESULTS: Among 337 patients, median estimated and hospital-measured weights were 79.0 kg (interquartile range [IQR], 66.0–94.5) and 78.5 kg (IQR, 65.0–91.7), respectively. The median of the absolute value of the difference in estimated versus measured weight was 2.7 kg (IQR, 0.6–7.6; P < .0001). The median percent difference in weight was 3.6% (IQR, 0.8%–9.4%). The median difference between the tissue plasminogen activator dosage administered on the MSU and the recommended dose based on the actual weight was 1.3 mg (IQR, 0.06–4.8) in absolute value. In 56 patients (16.6% of the entire sample) with overestimation of weight by greater than 10%, thereAbstract : ABSTRACT: BACKGROUND: Prehospital tissue plasminogen activator dosing in a mobile stroke unit (MSU) is estimated by the paramedic and nurse. We aimed to determine the accuracy of the estimated weight method compared with the actual weight of patients treated with tissue plasminogen activator on the MSU. METHODS: We prospectively collected the estimated weight used on the MSU for treatment and the first-documented hospital-measured weight (bed scale) within 24 hours of hospital arrival. Median absolute and percent difference in weights were calculated; less than 10% of difference in weights was considered acceptable. To compare the estimated and measured weights, we conducted a Wilcoxon signed rank test and Fisher exact test to explore the association between weight difference of greater than 10% and patient outcomes. RESULTS: Among 337 patients, median estimated and hospital-measured weights were 79.0 kg (interquartile range [IQR], 66.0–94.5) and 78.5 kg (IQR, 65.0–91.7), respectively. The median of the absolute value of the difference in estimated versus measured weight was 2.7 kg (IQR, 0.6–7.6; P < .0001). The median percent difference in weight was 3.6% (IQR, 0.8%–9.4%). The median difference between the tissue plasminogen activator dosage administered on the MSU and the recommended dose based on the actual weight was 1.3 mg (IQR, 0.06–4.8) in absolute value. In 56 patients (16.6% of the entire sample) with overestimation of weight by greater than 10%, there were no symptomatic intracerebral hemorrhages. There was no association between weight difference and discharge modified Rankin score ( P = .59). CONCLUSION: Weight estimation on an MSU can lead to similar tissue plasminogen activator dosing for 83.4% of subjects compared with if dosing were determined based on actual weight. Weight overestimation or underestimation had no detected impact on tissue plasminogen activator outcomes. … (more)
- Is Part Of:
- Journal of neuroscience nursing. Volume 53:Issue 4(2021)
- Journal:
- Journal of neuroscience nursing
- Issue:
- Volume 53:Issue 4(2021)
- Issue Display:
- Volume 53, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 53
- Issue:
- 4
- Issue Sort Value:
- 2021-0053-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-08
- Subjects:
- emergency medical services -- ischemic stroke -- mobile stroke -- tissue plasminogen activator -- transport nursing -- weight
Neurological nursing -- Periodicals
616.80231 - Journal URLs:
- http://journals.lww.com/jnnonline/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/JNN.0000000000000598 ↗
- Languages:
- English
- ISSNs:
- 0888-0395
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5022.085000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18963.xml