A comparison of double single suture-button fixation, suture-button fixation, and screw fixation for ankle syndesmosis injury: A retrospective cohort study. Issue 13 (2nd April 2021)
- Record Type:
- Journal Article
- Title:
- A comparison of double single suture-button fixation, suture-button fixation, and screw fixation for ankle syndesmosis injury: A retrospective cohort study. Issue 13 (2nd April 2021)
- Main Title:
- A comparison of double single suture-button fixation, suture-button fixation, and screw fixation for ankle syndesmosis injury
- Authors:
- Kurtoglu, Alper
Kochai, Alauddin
Inanmaz, Mustafa Erkan
Sukur, Erhan
Keskin, Dogan
Türker, Mehmet
Uysal, Mustafa
Sen, Zafer
Daldal, Ismail - Other Names:
- Kellam. James section editor.
- Abstract:
- Abstract : Abstract: Different methods have been used throughout the years for syndesmotic injury but there is no consensus on the ideal treatment. Some methods are expensive and some have more complications. The aim of this study is to compare single suture endobutton with double suture endobutton and screw fixation for syndesmotic injury. Sixty nine patients with syndesmotic injury with fibular fractures whom were treated with a single interosseous suture endobutton system (ZipTight TM, Zimmer Biomet), a double interosseous suture endobutton system (ZipTight TM, Zimmer Biomet) and 1 syndesmotic screw (TST, Istanbul, Turkey) were included in this study. Functional and radiological results from patient records between 2015 and 2018 were retrospectively evaluated. Twenty patients were treated with the double interosseous suture endobutton, 23 were treated with the single interosseous suture endobutton, and 26 were treated with traditional AO screw fixation. Three patients from the screw fixation group (11.5%) required revision surgery ( P < .05). All the radiologic and clinical outcomes were statistical similar in all 3 groups. Our findings showed that the interosseous suture endobutton system is at least as safe as the screw fixation technique for treatment of syndesmosis joint injuries and can be used as an alternative to the screw method. The interosseous suture endobutton system eliminates the need for a second surgery to remove the hardware, which minimizes theAbstract : Abstract: Different methods have been used throughout the years for syndesmotic injury but there is no consensus on the ideal treatment. Some methods are expensive and some have more complications. The aim of this study is to compare single suture endobutton with double suture endobutton and screw fixation for syndesmotic injury. Sixty nine patients with syndesmotic injury with fibular fractures whom were treated with a single interosseous suture endobutton system (ZipTight TM, Zimmer Biomet), a double interosseous suture endobutton system (ZipTight TM, Zimmer Biomet) and 1 syndesmotic screw (TST, Istanbul, Turkey) were included in this study. Functional and radiological results from patient records between 2015 and 2018 were retrospectively evaluated. Twenty patients were treated with the double interosseous suture endobutton, 23 were treated with the single interosseous suture endobutton, and 26 were treated with traditional AO screw fixation. Three patients from the screw fixation group (11.5%) required revision surgery ( P < .05). All the radiologic and clinical outcomes were statistical similar in all 3 groups. Our findings showed that the interosseous suture endobutton system is at least as safe as the screw fixation technique for treatment of syndesmosis joint injuries and can be used as an alternative to the screw method. The interosseous suture endobutton system eliminates the need for a second surgery to remove the hardware, which minimizes the probability of re-diastasis. Since our results showed no statistical difference between single and double interosseous suture endobutton systems, the less costly single endobutton system may be the better alternative. … (more)
- Is Part Of:
- Medicine. Volume 100:Issue 13(2021)
- Journal:
- Medicine
- Issue:
- Volume 100:Issue 13(2021)
- Issue Display:
- Volume 100, Issue 13 (2021)
- Year:
- 2021
- Volume:
- 100
- Issue:
- 13
- Issue Sort Value:
- 2021-0100-0013-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-04-02
- Subjects:
- ankle fracture -- American Orthopaedic Foot and Ankle Society -- screw fixation -- suture endobutton -- syndesmosis injury
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000025328 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18958.xml