Rapid Simultaneous Determination of 14 Antidepressants and 13 Antipsychotics in Human Plasma by Using High-Performance Liquid Chromatography–Tandem Mass Spectrometry With Dynamic Multiple Reaction Monitoring and Its Application to Therapeutic Drug Monitoring. Issue 4 (August 2021)
- Record Type:
- Journal Article
- Title:
- Rapid Simultaneous Determination of 14 Antidepressants and 13 Antipsychotics in Human Plasma by Using High-Performance Liquid Chromatography–Tandem Mass Spectrometry With Dynamic Multiple Reaction Monitoring and Its Application to Therapeutic Drug Monitoring. Issue 4 (August 2021)
- Main Title:
- Rapid Simultaneous Determination of 14 Antidepressants and 13 Antipsychotics in Human Plasma by Using High-Performance Liquid Chromatography–Tandem Mass Spectrometry With Dynamic Multiple Reaction Monitoring and Its Application to Therapeutic Drug Monitoring
- Authors:
- Lyu, Haiyan
Chen, Binbin
Xu, Xiangzhen
Zhu, Chunyan
Ma, Chunling
Du, Yu
Liu, Farong
Wu, Caisheng - Abstract:
- Abstract : Background: A comprehensive, stable, and efficient high-performance liquid chromatography–tandem mass spectrometry method was developed for rapidly analyzing 14 antidepressants and 13 antipsychotics in human plasma for routine clinical therapeutic drug monitoring. Methods: Simple protein precipitation was used for the pretreatment of plasma samples; dynamic multiple reaction monitoring was used to avoid the loss of sensitivity caused by numerous ion transitions. In all, 80 ion transitions of 40 compounds were quantitatively determined in 6 minutes. Results: The limit of detection for the 27 analytes was in the range of 0.1–30 ng/mL, and all calibration lines prepared using blank plasma were linear with a correlation coefficient of r 2 ≥ 0.99. The method was accurate and precise with acceptable intraday and interday precisions (coefficients of variation, ⩽20% for a lower limit of quantification and ⩽15% for other quality control samples) and an accuracy of 85.51%–114.77%. This analysis method has been completely validated and successfully used in routine clinical therapeutic drug monitoring for more than 9963 samples [including 488 samples having drug concentrations above the laboratory alert level (supra–alert-level samples)] at Xiamen Xianyue Hospital. Conclusions: This dynamic method is comprehensive (includes most antidepressants and antipsychotics listed in China), reliable (stably used for almost 2 years), and efficient (convenient sample processing and shortAbstract : Background: A comprehensive, stable, and efficient high-performance liquid chromatography–tandem mass spectrometry method was developed for rapidly analyzing 14 antidepressants and 13 antipsychotics in human plasma for routine clinical therapeutic drug monitoring. Methods: Simple protein precipitation was used for the pretreatment of plasma samples; dynamic multiple reaction monitoring was used to avoid the loss of sensitivity caused by numerous ion transitions. In all, 80 ion transitions of 40 compounds were quantitatively determined in 6 minutes. Results: The limit of detection for the 27 analytes was in the range of 0.1–30 ng/mL, and all calibration lines prepared using blank plasma were linear with a correlation coefficient of r 2 ≥ 0.99. The method was accurate and precise with acceptable intraday and interday precisions (coefficients of variation, ⩽20% for a lower limit of quantification and ⩽15% for other quality control samples) and an accuracy of 85.51%–114.77%. This analysis method has been completely validated and successfully used in routine clinical therapeutic drug monitoring for more than 9963 samples [including 488 samples having drug concentrations above the laboratory alert level (supra–alert-level samples)] at Xiamen Xianyue Hospital. Conclusions: This dynamic method is comprehensive (includes most antidepressants and antipsychotics listed in China), reliable (stably used for almost 2 years), and efficient (convenient sample processing and short run time) and provides a large amount of meaningful data for optimized pharmacotherapy. Our experimental data from the plasma concentrations of supra–alert-level samples could serve as a reference for the interpretation of the pharmacokinetics of patients with a high risk of toxicity or loss of tolerability. Abstract : Supplemental Digital Content is Available in the Text. … (more)
- Is Part Of:
- Therapeutic drug monitoring. Volume 43:Issue 4(2021)
- Journal:
- Therapeutic drug monitoring
- Issue:
- Volume 43:Issue 4(2021)
- Issue Display:
- Volume 43, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 43
- Issue:
- 4
- Issue Sort Value:
- 2021-0043-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-08
- Subjects:
- antidepressants -- antipsychotics -- HPLC-MS/MS -- TDM -- dynamic multiple reaction monitoring -- supra–alert-level samples
Pharmacokinetics -- Periodicals
Patient monitoring -- Periodicals
Drugs -- Analysis -- Periodicals
Body fluids -- Analysis -- Periodicals
Drug Therapy -- Periodicals
Monitoring, Physiologic -- Periodicals
Pharmacology -- Periodicals
615.7 - Journal URLs:
- http://journals.lww.com/drug-monitoring/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00007691-000000000-00000 ↗
http://www.drug-monitoring.com/ ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0163-4356 ↗ - DOI:
- 10.1097/FTD.0000000000000839 ↗
- Languages:
- English
- ISSNs:
- 0163-4356
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8814.643000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18951.xml