Efficacy and Safety of Simultaneous Application of HIFEM and Synchronized Radiofrequency for Abdominal Fat Reduction and Muscle Toning: A Multicenter Magnetic Resonance Imaging Evaluation Study. Issue 7 (July 2021)
- Record Type:
- Journal Article
- Title:
- Efficacy and Safety of Simultaneous Application of HIFEM and Synchronized Radiofrequency for Abdominal Fat Reduction and Muscle Toning: A Multicenter Magnetic Resonance Imaging Evaluation Study. Issue 7 (July 2021)
- Main Title:
- Efficacy and Safety of Simultaneous Application of HIFEM and Synchronized Radiofrequency for Abdominal Fat Reduction and Muscle Toning
- Authors:
- Jacob, Carolyn
Kent, David
Ibrahim, Omer - Abstract:
- Abstract : BACKGROUND: Radiofrequency and high-Intensity Focused Electromagnetic (HIFEM) field procedure are well-known, stand-alone, body-shaping modalities, yet their simultaneous application has not been investigated. OBJECTIVE: The aim is to evaluate the efficacy of a novel device simultaneously delivering HIFEM and radiofrequency for subcutaneous fat reduction and muscle toning. MATERIALS AND METHODS: Forty-one subjects with an average age of 39.7 ± 11.5 years were recruited. The subjects received 3 abdominal treatments (one per week). Magnetic resonance imaging images of the treated area were evaluated at baseline and at 1-, 3-, and 6-month visits for changes in subcutaneous fat, muscle thickness, and abdominal separation (AS). Anthropometric data and digital photographs were collected. Subject satisfaction and therapy comfort were evaluated. RESULTS: The muscle mass increase peaked at 3 months, showing 26.1% thickening. The fat thickness reduction was most prominent at 3 months, showing a 30.8% reduction. The AS decreased by 18.8% at 3 months after treatment. The waist circumference reduced by 5.87 ± 3.64 cm at a 3-month follow-up. Six-month data showed maintenance of these outcomes. The treatment was considered as comfortable with high patient satisfaction. CONCLUSION: The analysis of magnetic resonance imaging images and waist measurements showed that the therapy combining HIFEM and radiofrequency is highly effective in reducing subcutaneous fat and muscleAbstract : BACKGROUND: Radiofrequency and high-Intensity Focused Electromagnetic (HIFEM) field procedure are well-known, stand-alone, body-shaping modalities, yet their simultaneous application has not been investigated. OBJECTIVE: The aim is to evaluate the efficacy of a novel device simultaneously delivering HIFEM and radiofrequency for subcutaneous fat reduction and muscle toning. MATERIALS AND METHODS: Forty-one subjects with an average age of 39.7 ± 11.5 years were recruited. The subjects received 3 abdominal treatments (one per week). Magnetic resonance imaging images of the treated area were evaluated at baseline and at 1-, 3-, and 6-month visits for changes in subcutaneous fat, muscle thickness, and abdominal separation (AS). Anthropometric data and digital photographs were collected. Subject satisfaction and therapy comfort were evaluated. RESULTS: The muscle mass increase peaked at 3 months, showing 26.1% thickening. The fat thickness reduction was most prominent at 3 months, showing a 30.8% reduction. The AS decreased by 18.8% at 3 months after treatment. The waist circumference reduced by 5.87 ± 3.64 cm at a 3-month follow-up. Six-month data showed maintenance of these outcomes. The treatment was considered as comfortable with high patient satisfaction. CONCLUSION: The analysis of magnetic resonance imaging images and waist measurements showed that the therapy combining HIFEM and radiofrequency is highly effective in reducing subcutaneous fat and muscle thickening. … (more)
- Is Part Of:
- Dermatologic surgery. Volume 47:Issue 7(2021)
- Journal:
- Dermatologic surgery
- Issue:
- Volume 47:Issue 7(2021)
- Issue Display:
- Volume 47, Issue 7 (2021)
- Year:
- 2021
- Volume:
- 47
- Issue:
- 7
- Issue Sort Value:
- 2021-0047-0007-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-07
- Subjects:
- Skin -- Surgery -- Periodicals
Skin -- Diseases -- Surgery -- Periodicals
617.477 - Journal URLs:
- http://journals.lww.com ↗
- DOI:
- 10.1097/DSS.0000000000003086 ↗
- Languages:
- English
- ISSNs:
- 1076-0512
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3555.140000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18951.xml