MACULAR SENSITIVITY IN THE AREA OF INTERNAL LIMITING MEMBRANE PEELING IN EYES AFTER PARS PLANA VITRECTOMY WITH THE TEMPORAL INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE FOR A FULL-THICKNESS MACULAR HOLE. Issue 8 (August 2021)
- Record Type:
- Journal Article
- Title:
- MACULAR SENSITIVITY IN THE AREA OF INTERNAL LIMITING MEMBRANE PEELING IN EYES AFTER PARS PLANA VITRECTOMY WITH THE TEMPORAL INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE FOR A FULL-THICKNESS MACULAR HOLE. Issue 8 (August 2021)
- Main Title:
- MACULAR SENSITIVITY IN THE AREA OF INTERNAL LIMITING MEMBRANE PEELING IN EYES AFTER PARS PLANA VITRECTOMY WITH THE TEMPORAL INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE FOR A FULL-THICKNESS MACULAR HOLE
- Authors:
- Kaluzny, Jakub J.
Zabel, Przemysław
Kaluzna, Martyna
Lamkowski, Aleksander
Jaworski, Damian
Woznicki, Krzysztof
Zabel, Katarzyna - Abstract:
- Abstract : Purpose: To examine the relationship between retinal sensitivity and the area of internal limiting membrane (ILM) peeling during pars plana vitrectomy for a full-thickness macular hole. Methods: Twenty-four eyes a minimum of 6 months after temporal inverted flap pars plana vitrectomy for a full-thickness macular hole were included in the study. En face spectral-domain optical coherence tomography images were used to assess margins of the peeled ILM area. Microperimetry was performed to examine retinal sensitivity within the central 10°. Areas of peeled ILM in en face optical coherence tomography images were correlated with the average sensitivity threshold. Retinal sensitivities at the location of each measurement point were compared with structural abnormalities observed in en face spectral-domain optical coherence tomography images. Results: The mean retinal sensitivity in the area of ILM removal was significantly lower compared with the area of preserved ILM (24.29 ± 3.96 dB vs. 26.19 ± 2.10 dB, P < 0.0001, respectively). The peeled ILM area showed a negative correlation with the average sensitivity threshold (r = −0.56, P < 0.01). Conclusion: A larger area of ILM peeling during temporal inverted flap pars plana vitrectomy for a full-thickness macular hole is related to lower retinal sensitivity in the central macula. Abstract : In eyes after temporal inverted internal limiting membrane flap pars plana vitrectomy for a full-thickness macular hole the retinalAbstract : Purpose: To examine the relationship between retinal sensitivity and the area of internal limiting membrane (ILM) peeling during pars plana vitrectomy for a full-thickness macular hole. Methods: Twenty-four eyes a minimum of 6 months after temporal inverted flap pars plana vitrectomy for a full-thickness macular hole were included in the study. En face spectral-domain optical coherence tomography images were used to assess margins of the peeled ILM area. Microperimetry was performed to examine retinal sensitivity within the central 10°. Areas of peeled ILM in en face optical coherence tomography images were correlated with the average sensitivity threshold. Retinal sensitivities at the location of each measurement point were compared with structural abnormalities observed in en face spectral-domain optical coherence tomography images. Results: The mean retinal sensitivity in the area of ILM removal was significantly lower compared with the area of preserved ILM (24.29 ± 3.96 dB vs. 26.19 ± 2.10 dB, P < 0.0001, respectively). The peeled ILM area showed a negative correlation with the average sensitivity threshold (r = −0.56, P < 0.01). Conclusion: A larger area of ILM peeling during temporal inverted flap pars plana vitrectomy for a full-thickness macular hole is related to lower retinal sensitivity in the central macula. Abstract : In eyes after temporal inverted internal limiting membrane flap pars plana vitrectomy for a full-thickness macular hole the retinal sensitivity in the area of internal limiting membrane peeling is reduced comparing to part of fovea where the internal limiting membrane is preserved. There is a significant correlation between the internal limiting membrane peeling area and average macular sensitivity. … (more)
- Is Part Of:
- Retina. Volume 41:Issue 8(2021)
- Journal:
- Retina
- Issue:
- Volume 41:Issue 8(2021)
- Issue Display:
- Volume 41, Issue 8 (2021)
- Year:
- 2021
- Volume:
- 41
- Issue:
- 8
- Issue Sort Value:
- 2021-0041-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-08
- Subjects:
- en face OCT -- idiopathic full-thickness macular hole -- ILM -- ILM peeling -- inverted ILM flap -- pars plana vitrectomy -- microperimetry -- retinal sensitivity
Retina -- Diseases -- Periodicals
Retinal Diseases
Vitreous Body
617.735 - Journal URLs:
- http://journals.lww.com/retinajournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/IAE.0000000000003096 ↗
- Languages:
- English
- ISSNs:
- 0275-004X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7785.510300
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18953.xml