Safety and efficacy of left bundle branch pacing in comparison with conventional right ventricular pacing: A systematic review and meta-analysis. Issue 27 (9th July 2021)
- Record Type:
- Journal Article
- Title:
- Safety and efficacy of left bundle branch pacing in comparison with conventional right ventricular pacing: A systematic review and meta-analysis. Issue 27 (9th July 2021)
- Main Title:
- Safety and efficacy of left bundle branch pacing in comparison with conventional right ventricular pacing
- Authors:
- Liu, Xing
Li, Wenbin
Wang, Lei
Tian, Shaohua
Zhou, Xiaolin
Wu, Mingxing - Other Names:
- Patel. Neil section editor.
- Abstract:
- Abstract: Background: Right ventricular pacing (RVP) has been widely accepted as a traditional pacing strategy, but long-term RVP has detrimental impact on ventricular synchrony. However, left bundle branch pacing (LBBP) that evolved from His-bundle pacing could maintain ventricular synchrony and overcome its clinical deficiencies such as difficulty of lead implantation, His bundle damage, and high and unstable thresholds. This analysis aimed to appraise the clinical safety and efficacy of LBBP. Methods: The Medline, PubMed, Embase, and the Cochrane Library databases from inception to November 2020 were searched for studies comparing LBBP and RVP. Results: Seven trials with 451 patients (221 patients underwent LBBP and 230 patients underwent RVP) were included in the analysis. Pooled analyses verified that the paced QRS duration (QRSd) and left ventricular mechanical synchronization parameters of the LBBP capture were similar with the native-conduction mode ( P > .7), but LBBP showed shorter QRS duration (weighted mean difference [WMD]: −33.32; 95% confidence interval [CI], −40.44 to −26.19, P < .001), better left ventricular mechanical synchrony (standard mean differences: −1.5; 95% CI: −1.85 to −1.14, P < .001) compared with RVP. No significant differences in Pacing threshold (WMD: 0.01; 95% CI: −0.08 to 0.09, P < .001), R wave amplitude (WMD: 0.04; 95% CI: −1.12 to 1.19, P = .95) were noted between LBBP and RVP. Ventricular impedance of LBBP was higher than that ofAbstract: Background: Right ventricular pacing (RVP) has been widely accepted as a traditional pacing strategy, but long-term RVP has detrimental impact on ventricular synchrony. However, left bundle branch pacing (LBBP) that evolved from His-bundle pacing could maintain ventricular synchrony and overcome its clinical deficiencies such as difficulty of lead implantation, His bundle damage, and high and unstable thresholds. This analysis aimed to appraise the clinical safety and efficacy of LBBP. Methods: The Medline, PubMed, Embase, and the Cochrane Library databases from inception to November 2020 were searched for studies comparing LBBP and RVP. Results: Seven trials with 451 patients (221 patients underwent LBBP and 230 patients underwent RVP) were included in the analysis. Pooled analyses verified that the paced QRS duration (QRSd) and left ventricular mechanical synchronization parameters of the LBBP capture were similar with the native-conduction mode ( P > .7), but LBBP showed shorter QRS duration (weighted mean difference [WMD]: −33.32; 95% confidence interval [CI], −40.44 to −26.19, P < .001), better left ventricular mechanical synchrony (standard mean differences: −1.5; 95% CI: −1.85 to −1.14, P < .001) compared with RVP. No significant differences in Pacing threshold (WMD: 0.01; 95% CI: −0.08 to 0.09, P < .001), R wave amplitude (WMD: 0.04; 95% CI: −1.12 to 1.19, P = .95) were noted between LBBP and RVP. Ventricular impedance of LBBP was higher than that of RVP originally (WMD: 19.34; 95% CI: 3.13–35.56, P = .02), and there was no difference between the 2 groups after follow-up (WMD: 11.78; 95% CI: −24.48 to 48.04, P = .52). And follow-up pacing threshold of LBBP kept stability (WMD: 0.08; 95% CI: −0.09 to 0.25, P = .36). However, no statistical difference existed in ejection fraction between the 2 groups (WMD: 1.41; 95% CI: −1.72 to 4.54, P = .38). Conclusions: The safety and efficacy of LBBP was firstly verified by meta-analysis to date. LBBP markedly preserve ventricular electrical and mechanical synchrony compared with RVP. Meanwhile, LBBP had stable and excellent pacing parameters. However, LBBP could not be significant difference in ejection fraction between RVP during short- term follow-up. … (more)
- Is Part Of:
- Medicine. Volume 100:Issue 27(2021)
- Journal:
- Medicine
- Issue:
- Volume 100:Issue 27(2021)
- Issue Display:
- Volume 100, Issue 27 (2021)
- Year:
- 2021
- Volume:
- 100
- Issue:
- 27
- Issue Sort Value:
- 2021-0100-0027-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-07-09
- Subjects:
- efficacy -- his-bundle pacing -- left bundle branch pacing -- right ventricular pacing -- safety
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000026560 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18963.xml