Correlation between real-time heart rate and fatigue in chest compression providers during cardiopulmonary resuscitation: A simulation-based interventional study. Issue 16 (23rd April 2021)
- Record Type:
- Journal Article
- Title:
- Correlation between real-time heart rate and fatigue in chest compression providers during cardiopulmonary resuscitation: A simulation-based interventional study. Issue 16 (23rd April 2021)
- Main Title:
- Correlation between real-time heart rate and fatigue in chest compression providers during cardiopulmonary resuscitation
- Authors:
- Bae, Go Eun
Choi, Arom
Beom, Jin Ho
Kim, Min Joung
Chung, Hyun Soo
Min, In Kyung
Chung, Sung Phil
Kim, Ji Hoon - Other Names:
- Mayr. Johannes section editor.
- Abstract:
- Abstract: Background: The American Heart Association guidelines recommend switching chest compression providers at least every 2 min depending on their fatigue during cardiopulmonary resuscitation (CPR). Although the provider's heart rate is widely used as an objective indicator for detecting fatigue, the accuracy of this measure is debatable. Objectives: This study was designed to determine whether real-time heart rate is a measure of fatigue in compression providers. Study design: A simulation-based prospective interventional study including 110 participants. Methods: Participants performed chest compressions in pairs for four cycles using advanced cardiovascular life support simulation. Each participant's heart rate was measured using wearable healthcare devices, and qualitative variables regarding individual compressions were obtained from computerized devices. The primary outcome was correct depth of chest compressions. The main exposure was the change in heart rate, defined as the difference between the participant's heart rate during individual compressions and that before the simulation was initiated. Results: With a constant compression duration for one cycle, the overall accuracy of compression depth significantly decreased with increasing heart rate. Female participants displayed significantly decreased accuracy of compression depth with increasing heart rate (odds ratio [OR]: 0.97; 95% confidence interval [CI]: 0.95–0.98; P < .001). Conversely, male participantsAbstract: Background: The American Heart Association guidelines recommend switching chest compression providers at least every 2 min depending on their fatigue during cardiopulmonary resuscitation (CPR). Although the provider's heart rate is widely used as an objective indicator for detecting fatigue, the accuracy of this measure is debatable. Objectives: This study was designed to determine whether real-time heart rate is a measure of fatigue in compression providers. Study design: A simulation-based prospective interventional study including 110 participants. Methods: Participants performed chest compressions in pairs for four cycles using advanced cardiovascular life support simulation. Each participant's heart rate was measured using wearable healthcare devices, and qualitative variables regarding individual compressions were obtained from computerized devices. The primary outcome was correct depth of chest compressions. The main exposure was the change in heart rate, defined as the difference between the participant's heart rate during individual compressions and that before the simulation was initiated. Results: With a constant compression duration for one cycle, the overall accuracy of compression depth significantly decreased with increasing heart rate. Female participants displayed significantly decreased accuracy of compression depth with increasing heart rate (odds ratio [OR]: 0.97; 95% confidence interval [CI]: 0.95–0.98; P < .001). Conversely, male participants displayed significantly improved accuracy with increasing heart rate (OR: 1.03; 95% CI: 1.02–1.04; P < .001). Conclusion: Increasing heart rate could reflect fatigue in providers performing chest compressions with a constant duration for one cycle. Thus, provider rotation should be considered according to objectively measured fatigue during CPR. … (more)
- Is Part Of:
- Medicine. Volume 100:Issue 16(2021)
- Journal:
- Medicine
- Issue:
- Volume 100:Issue 16(2021)
- Issue Display:
- Volume 100, Issue 16 (2021)
- Year:
- 2021
- Volume:
- 100
- Issue:
- 16
- Issue Sort Value:
- 2021-0100-0016-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-04-23
- Subjects:
- cardiopulmonary resuscitation -- chest compression quality -- provider's fatigue -- wearable device
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000025425 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18961.xml