Final five‐year results of the REMEDEE Registry: Real‐world experience with the dual‐therapy COMBO stent. Issue 3 (8th October 2020)
- Record Type:
- Journal Article
- Title:
- Final five‐year results of the REMEDEE Registry: Real‐world experience with the dual‐therapy COMBO stent. Issue 3 (8th October 2020)
- Main Title:
- Final five‐year results of the REMEDEE Registry: Real‐world experience with the dual‐therapy COMBO stent
- Authors:
- Kerkmeijer, Laura S.M.
Chandrasekhar, Jaya
Kalkman, Deborah N.
Woudstra, Pier
Menown, Ian B.A.
Suryapranata, Harry
den Heijer, Peter
Iñiguez, Andrés
van 't Hof, Arnoud W.J.
Erglis, Andrejs
Arkenbout, Karin E.
Muller, Philippe
Koch, Karel T.
Tijssen, Jan G.
Beijk, Marcel A.M.
de Winter, Robbert J. - Abstract:
- Abstract: Objectives: This final report from the REMEDEE Registry assessed the long‐term safety and efficacy of the dual‐therapy COMBO stent in a large unselected patient population. Background: The bio‐engineered COMBO stent (OrbusNeich Medical BV, The Netherlands) is a dual‐therapy pro‐healing stent. Data of long‐term safety and efficacy of the this stent is lacking. Methods: The prospective, multicenter, investigator‐initiated REMEDEE Registry evaluated clinical outcomes after COMBO stent implantation in daily clinical practice. One thousand patients were enrolled between June 2013 and March 2014. Results: Five‐year follow‐up data were obtained in 97.2% of patients. At 5‐years, target lesion failure (TLF) (composite of cardiac death, target‐vessel myocardial infarction, or target lesion revascularization) was present in 145 patients (14.8%). Definite or probable stent thrombosis (ST) occurred in 0.9%, with no additional case beyond 3‐years of follow‐up. In males, 5‐year TLF‐rate was 15.6 versus 12.6% in females ( p = .22). Patients without diabetes mellitus (DM) had TLF‐rate of 11.4%, noninsulin‐treated DM 22.7% ( p = .001) and insulin‐treated DM 41.2% ( p < .001). Patients presenting with non‐ST segment elevation acute coronary syndrome (NSTE‐ACS) had higher incidence of TLF compared to non‐ACS (20.4 vs. 13.3%; p = .008), while incidence with STE‐ACS was comparable to non‐ACS (10.7 vs. 13.3%; p = .43). Conclusion: Percutaneous coronary intervention with the dual‐therapyAbstract: Objectives: This final report from the REMEDEE Registry assessed the long‐term safety and efficacy of the dual‐therapy COMBO stent in a large unselected patient population. Background: The bio‐engineered COMBO stent (OrbusNeich Medical BV, The Netherlands) is a dual‐therapy pro‐healing stent. Data of long‐term safety and efficacy of the this stent is lacking. Methods: The prospective, multicenter, investigator‐initiated REMEDEE Registry evaluated clinical outcomes after COMBO stent implantation in daily clinical practice. One thousand patients were enrolled between June 2013 and March 2014. Results: Five‐year follow‐up data were obtained in 97.2% of patients. At 5‐years, target lesion failure (TLF) (composite of cardiac death, target‐vessel myocardial infarction, or target lesion revascularization) was present in 145 patients (14.8%). Definite or probable stent thrombosis (ST) occurred in 0.9%, with no additional case beyond 3‐years of follow‐up. In males, 5‐year TLF‐rate was 15.6 versus 12.6% in females ( p = .22). Patients without diabetes mellitus (DM) had TLF‐rate of 11.4%, noninsulin‐treated DM 22.7% ( p = .001) and insulin‐treated DM 41.2% ( p < .001). Patients presenting with non‐ST segment elevation acute coronary syndrome (NSTE‐ACS) had higher incidence of TLF compared to non‐ACS (20.4 vs. 13.3%; p = .008), while incidence with STE‐ACS was comparable to non‐ACS (10.7 vs. 13.3%; p = .43). Conclusion: Percutaneous coronary intervention with the dual‐therapy COMBO stent in unselected patient population shows low rates of TLF and ST to 5 years. Remarkably, no case of ST was noted beyond 3 years. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 98:Issue 3(2021)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 98:Issue 3(2021)
- Issue Display:
- Volume 98, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 98
- Issue:
- 3
- Issue Sort Value:
- 2021-0098-0003-0000
- Page Start:
- 503
- Page End:
- 510
- Publication Date:
- 2020-10-08
- Subjects:
- drug‐eluting stent -- dual‐therapy stent -- percutaneous coronary intervention
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.29305 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18938.xml