Blood pressure measurement during cesarean delivery: Evaluation of a beat-to-beat noninvasive device (NexfinTM). Issue 22 (4th June 2021)
- Record Type:
- Journal Article
- Title:
- Blood pressure measurement during cesarean delivery: Evaluation of a beat-to-beat noninvasive device (NexfinTM). Issue 22 (4th June 2021)
- Main Title:
- Blood pressure measurement during cesarean delivery
- Authors:
- Bobet, Mathieu
Joachim, Jona
Gayat, Etienne
Bonnet, Agnès
Sievert, Kerstin
Barnichon, Carole
Fischler, Marc
Le Guen, Morgan - Other Names:
- Ting. Chien-Kun section editor.
- Abstract:
- Abstract : Abstract: Early detection of arterial hypotension during cesarean delivery under spinal anesthesia is important. This study aims to compare the validity of Nexfin TM as beat-to-beat noninvasive blood pressure monitoring with conventional intermittent oscillometric measurement of blood pressure during elective cesarean delivery. This open prospective observational bicentric study was performed between January 2013 and December 2015. We simultaneously recorded arterial blood pressure with both techniques in pregnant women undergoing elective cesarean delivery under spinal anesthesia. The primary outcome was a Bland–Altman analysis of systolic blood pressure measurement comparing Nexfin TM and a conventional method. The secondary outcomes were the time to detect the first relevant hypotensive episode and the comparison of both devices using a four-quadrant graph. One hundred and seventy-four parturients completed the study, and 2640 pairs of systolic blood pressure measurements were analyzed. Bias was -10 mmHg with upper and lower limits of agreement of -61 and +41 mmHg. In 73.9% of the cases, the two techniques provided the same information (normotension or hypotension), but the conventional method missed 20.8% of measurements, with Nexfin TM detecting 16.2% more hypotensive measurements. The median [25–75 percentiles] duration to detect the first hypotensive measurement was 331 [206–480] seconds for Nexfin TM and 440 [300–500] s for intermittent oscillometry ( PAbstract : Abstract: Early detection of arterial hypotension during cesarean delivery under spinal anesthesia is important. This study aims to compare the validity of Nexfin TM as beat-to-beat noninvasive blood pressure monitoring with conventional intermittent oscillometric measurement of blood pressure during elective cesarean delivery. This open prospective observational bicentric study was performed between January 2013 and December 2015. We simultaneously recorded arterial blood pressure with both techniques in pregnant women undergoing elective cesarean delivery under spinal anesthesia. The primary outcome was a Bland–Altman analysis of systolic blood pressure measurement comparing Nexfin TM and a conventional method. The secondary outcomes were the time to detect the first relevant hypotensive episode and the comparison of both devices using a four-quadrant graph. One hundred and seventy-four parturients completed the study, and 2640 pairs of systolic blood pressure measurements were analyzed. Bias was -10 mmHg with upper and lower limits of agreement of -61 and +41 mmHg. In 73.9% of the cases, the two techniques provided the same information (normotension or hypotension), but the conventional method missed 20.8% of measurements, with Nexfin TM detecting 16.2% more hypotensive measurements. The median [25–75 percentiles] duration to detect the first hypotensive measurement was 331 [206–480] seconds for Nexfin TM and 440 [300–500] s for intermittent oscillometry ( P < .001). The agreement between Nexfin TM and an intermittent method for the measurement of systolic blood pressure was not in an acceptable range during cesarean delivery, although Nexfin TM may detect hypotension earlier than the standard method. Trial registration: Clinicaltrials.gov identifier: NCT01732133; November 22, 2012 … (more)
- Is Part Of:
- Medicine. Volume 100:Issue 22(2021)
- Journal:
- Medicine
- Issue:
- Volume 100:Issue 22(2021)
- Issue Display:
- Volume 100, Issue 22 (2021)
- Year:
- 2021
- Volume:
- 100
- Issue:
- 22
- Issue Sort Value:
- 2021-0100-0022-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-06-04
- Subjects:
- arterial pressure -- cesarean section -- intraoperative -- monitoring -- monitoring -- noninvasive
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000026129 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18912.xml