Impact of Wideband Late Gadolinium Enhancement Cardiac Magnetic Resonance Imaging on Device‐Related Artifacts in Different Implantable Cardioverter‐Defibrillator Types. Issue 4 (19th March 2021)
- Record Type:
- Journal Article
- Title:
- Impact of Wideband Late Gadolinium Enhancement Cardiac Magnetic Resonance Imaging on Device‐Related Artifacts in Different Implantable Cardioverter‐Defibrillator Types. Issue 4 (19th March 2021)
- Main Title:
- Impact of Wideband Late Gadolinium Enhancement Cardiac Magnetic Resonance Imaging on Device‐Related Artifacts in Different Implantable Cardioverter‐Defibrillator Types
- Authors:
- Singh, Amita
Chen, Wensu
Patel, Hena N.
Alvi, Nazia
Kawaji, Keigo
Besser, Stephanie A.
Tung, Roderick
Zou, Jiangang
Lang, Roberto M.
Mor‐Avi, Victor
Patel, Amit R. - Abstract:
- Abstract : Background: Late gadolinium enhancement (LGE) imaging in patients with implantable cardioverter‐defibrillators (ICD) is limited by device‐related artifacts (DRA). The use of wideband (WB) LGE protocols improves LGE images, but their efficacy with different ICD types is not well known. Purpose: To assess the effects of WB LGE imaging on DRA in different non‐MR conditional ICD subtypes. Study Type: Retrospective. Population: A total of 113 patients undergoing cardiac magnetic resonance imaging with three ICD subtypes: transvenous (TV‐ICD, N = 48), cardiac‐resynchronization therapy device (CRT‐D, N = 48), and subcutaneous (S‐ICD, N = 17). Field Strength/Sequence: 5 T scanner, standard LGE, and WB LGE imaging with a phase‐sensitive inversion recovery segmented gradient echo sequence. Assessment: DRA burden was defined as the number of artifact‐positive short‐axis LGE slices as percentage of the total number of short‐axis slices covering the left ventricle from based to apex, and was determined for WB and standard LGE studies for each patient. Additionally, artifact area on each slice was quantified. Statistical Tests: Shapiro–Wilks, Kruskal–Wallis analysis of variance, Dunn tests with Bonferroni correction, and Mann–Whitney U ‐test. Results: In patients with TV‐ICD, DRA burden was significantly reduced and nearly eliminated with WB LGE compared to standard LGE imaging (median [interquartile range]: 0 [0–7]% vs. 18 [0–50]%, P < 0.05), but WB imaging had less of anAbstract : Background: Late gadolinium enhancement (LGE) imaging in patients with implantable cardioverter‐defibrillators (ICD) is limited by device‐related artifacts (DRA). The use of wideband (WB) LGE protocols improves LGE images, but their efficacy with different ICD types is not well known. Purpose: To assess the effects of WB LGE imaging on DRA in different non‐MR conditional ICD subtypes. Study Type: Retrospective. Population: A total of 113 patients undergoing cardiac magnetic resonance imaging with three ICD subtypes: transvenous (TV‐ICD, N = 48), cardiac‐resynchronization therapy device (CRT‐D, N = 48), and subcutaneous (S‐ICD, N = 17). Field Strength/Sequence: 5 T scanner, standard LGE, and WB LGE imaging with a phase‐sensitive inversion recovery segmented gradient echo sequence. Assessment: DRA burden was defined as the number of artifact‐positive short‐axis LGE slices as percentage of the total number of short‐axis slices covering the left ventricle from based to apex, and was determined for WB and standard LGE studies for each patient. Additionally, artifact area on each slice was quantified. Statistical Tests: Shapiro–Wilks, Kruskal–Wallis analysis of variance, Dunn tests with Bonferroni correction, and Mann–Whitney U ‐test. Results: In patients with TV‐ICD, DRA burden was significantly reduced and nearly eliminated with WB LGE compared to standard LGE imaging (median [interquartile range]: 0 [0–7]% vs. 18 [0–50]%, P < 0.05), but WB imaging had less of an impact on DRA in the CRT‐D (8 [0–23]% vs. 16 [0–45]%, p = 0.12) and S‐ICD (60 [15–71]% vs. 67 [50–92]%, P = 0.09) patients. Residual DRA was significantly greater ( P < 0.05) for S‐ICD compared to other device types with WB LGE imaging, despite the generators of all three ICD types having similar proximity to the heart. The area of S‐ICD associated DRA was smaller with WB LGE ( P < 0.001) than with standard LGE imaging and the artifacts had different characteristics (dark signal void instead of a bright hyperenhancement artifact). Data Conclusion: Although WB LGE imaging reduced the burden of DRA caused by S‐ICD, the residual artifact was greater than that observed with TV‐ICD and CRT‐D devices. Further developments are needed to better resolve S‐ICD artifacts. Level of Evidence: 1 Technical Efficacy: Stage: 5 … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 54:Issue 4(2021)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 54:Issue 4(2021)
- Issue Display:
- Volume 54, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 54
- Issue:
- 4
- Issue Sort Value:
- 2021-0054-0004-0000
- Page Start:
- 1257
- Page End:
- 1265
- Publication Date:
- 2021-03-19
- Subjects:
- cardiac magnetic resonance -- implantable cardioverter‐defibrillator -- heart failure -- ventricular tachycardia
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.27608 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18929.xml