Relationship Between Glenoid Component Shift and Osteolysis After Anatomic Total Shoulder Arthroplasty: Three-Dimensional Computed Tomography Analysis. (4th August 2021)
- Record Type:
- Journal Article
- Title:
- Relationship Between Glenoid Component Shift and Osteolysis After Anatomic Total Shoulder Arthroplasty: Three-Dimensional Computed Tomography Analysis. (4th August 2021)
- Main Title:
- Relationship Between Glenoid Component Shift and Osteolysis After Anatomic Total Shoulder Arthroplasty
- Authors:
- Ricchetti, Eric T.
Jun, Bong-Jae
Jin, Yuxuan
Ho, Jason C.
Patterson, Thomas E.
Dalton, Jarrod E.
Derwin, Kathleen A.
Iannotti, Joseph P. - Abstract:
- Abstract : Background: The purpose of this study was to evaluate glenoid component position and radiolucency following anatomic total shoulder arthroplasty (TSA) using sequential 3-dimensional computed tomography (3D CT) analysis. Methods: In a series of 152 patients (42 Walch A1, 16 A2, 7 B1, 49 B2, 29 B3, 3 C1, 3 C2, and 3 D glenoids) undergoing anatomic TSA with a polyethylene glenoid component, sequential 3D CT analysis was performed preoperatively (CT1), early postoperatively (CT2), and at a minimum 2-year follow-up (CT3). Glenoid component shift was defined as a change in component version or inclination of ≥3° from CT2 to CT3. Glenoid component central anchor peg osteolysis (CPO) was assessed at CT3. Factors associated with glenoid component shift and CPO were evaluated. Results: Glenoid component shift occurred from CT2 to CT3 in 78 (51%) of the 152 patients. CPO was seen at CT3 in 19 (13%) of the 152 patients, including 15 (19%) of the 78 with component shift. Walch B2 glenoids with a standard component and glenoids with higher preoperative retroversion were associated with a higher rate of shift, but not of CPO. B3 glenoids with an augmented component and glenoids with greater preoperative joint-line medialization were associated with CPO, but not with shift. More glenoid component joint-line medialization from CT2 to CT3 was associated with higher rates of shift and CPO. A greater absolute change in glenoid component inclination from CT2 to CT3 and a combinedAbstract : Background: The purpose of this study was to evaluate glenoid component position and radiolucency following anatomic total shoulder arthroplasty (TSA) using sequential 3-dimensional computed tomography (3D CT) analysis. Methods: In a series of 152 patients (42 Walch A1, 16 A2, 7 B1, 49 B2, 29 B3, 3 C1, 3 C2, and 3 D glenoids) undergoing anatomic TSA with a polyethylene glenoid component, sequential 3D CT analysis was performed preoperatively (CT1), early postoperatively (CT2), and at a minimum 2-year follow-up (CT3). Glenoid component shift was defined as a change in component version or inclination of ≥3° from CT2 to CT3. Glenoid component central anchor peg osteolysis (CPO) was assessed at CT3. Factors associated with glenoid component shift and CPO were evaluated. Results: Glenoid component shift occurred from CT2 to CT3 in 78 (51%) of the 152 patients. CPO was seen at CT3 in 19 (13%) of the 152 patients, including 15 (19%) of the 78 with component shift. Walch B2 glenoids with a standard component and glenoids with higher preoperative retroversion were associated with a higher rate of shift, but not of CPO. B3 glenoids with an augmented component and glenoids with greater preoperative joint-line medialization were associated with CPO, but not with shift. More glenoid component joint-line medialization from CT2 to CT3 was associated with higher rates of shift and CPO. A greater absolute change in glenoid component inclination from CT2 to CT3 and a combined absolute glenoid component version and inclination change from CT2 to CT3 were associated with CPO. Neither glenoid component shift nor CPO was associated with worse clinical outcomes. Conclusions: Postoperative 3D CT analysis demonstrated that glenoid component shift commonly occurs following anatomic TSA, with increased inclination the most common direction. Most (81%) of the patients with glenoid component shift did not develop CPO. Longer follow-up is needed to determine the relationships of glenoid component shift and CPO with loosening over time. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence. … (more)
- Is Part Of:
- Journal of bone and joint surgery. Volume 103:Number 15(2021)
- Journal:
- Journal of bone and joint surgery
- Issue:
- Volume 103:Number 15(2021)
- Issue Display:
- Volume 103, Issue 15 (2021)
- Year:
- 2021
- Volume:
- 103
- Issue:
- 15
- Issue Sort Value:
- 2021-0103-0015-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-08-04
- Subjects:
- Bones -- Surgery -- Periodicals
Joints -- Surgery -- Periodicals
Orthopedics -- Periodicals
Orthopedics
General Surgery
Bone Diseases
Joint Diseases
Bones -- Surgery
Joints -- Surgery
Orthopedics
Bot (anatomie)
Gewrichten
Chirurgie (geneeskunde)
Periodicals
Electronic journals
Periodicals
617.47005 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/00219355 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219355 ↗
http://www.ejbjs.org/contents-by-date.0.dtl ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.2106/JBJS.20.00833 ↗
- Languages:
- English
- ISSNs:
- 0021-9355
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.250000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18937.xml