Efficacy and airway complications of Parker Flex-Tip tubes and standard endotracheal tubes during airway manipulation: A meta-analysis and trial sequential analysis. Issue 8 (August 2021)
- Record Type:
- Journal Article
- Title:
- Efficacy and airway complications of Parker Flex-Tip tubes and standard endotracheal tubes during airway manipulation: A meta-analysis and trial sequential analysis. Issue 8 (August 2021)
- Main Title:
- Efficacy and airway complications of Parker Flex-Tip tubes and standard endotracheal tubes during airway manipulation
- Authors:
- Hung, Kuo-Chuan
Chen, Jen-Yin
Feng, I-Jung
Chiang, Min-Hsien
Wu, Shao-Chun
Chen, I-Wen
Lin, Yao-Tsung
Chang, Ying-Jen
Wu, Zhi-Fu
Lu, Hsiao-Feng
Sun, Cheuk-Kwan - Abstract:
- Abstract : BACKGROUND: Despite reported superior intubation outcomes associated with Parker Flex-Tip (PFT) tubes compared with those associated with standard polyvinylchloride tubes, the efficacy and safety of PFT tubes remain uncertain. OBJECTIVES: To compare the intubation outcomes between PFT and conventional standard polyvinylchloride tubes. DESIGN: Meta-analysis of randomised controlled trials. DATA SOURCES: Embase, Medline, Google Scholar, PubMed and the Cochrane controlled trials register from inception until 3 January 2021. ELIGIBILITY CRITERIA: All randomised trials comparing intubation outcomes between PFT (PFT group) and standard polyvinylchloride (standard polyvinylchloride group) tubes. RESULTS: Analysis of the 13 eligible trials showed no significant difference in successful first-attempt intubation rate [risk ratio (RR) 1.20, 95% confidence interval (CI) 0.99 to 1.44] (6 trials, 568 participants), trauma risk (RR 0.83, 95% CI 0.67 to 1.03) (5 trials, 501 participants) as well as the overall risks of epistaxis (RR 0.58, 95% CI 0.26 to 1.31) (3 trials, 262 participants), sore throat (RR 0.90, 95% CI 0.70 to 1.17) (4 trials, 451 participants) and hoarseness (RR 0.71, 95% CI 0.44 to 1.14) (4 trials, 451 participants) between the two groups. However, the intubation time was slightly shorter (weighted mean difference −4.2 s, 95% CI −7.4 to −1.0 s) (8 trials, 759 participants) and the risks of severe epistaxis (RR 0.15, 95% CI 0.03 to 0.84) (3 trials, 262Abstract : BACKGROUND: Despite reported superior intubation outcomes associated with Parker Flex-Tip (PFT) tubes compared with those associated with standard polyvinylchloride tubes, the efficacy and safety of PFT tubes remain uncertain. OBJECTIVES: To compare the intubation outcomes between PFT and conventional standard polyvinylchloride tubes. DESIGN: Meta-analysis of randomised controlled trials. DATA SOURCES: Embase, Medline, Google Scholar, PubMed and the Cochrane controlled trials register from inception until 3 January 2021. ELIGIBILITY CRITERIA: All randomised trials comparing intubation outcomes between PFT (PFT group) and standard polyvinylchloride (standard polyvinylchloride group) tubes. RESULTS: Analysis of the 13 eligible trials showed no significant difference in successful first-attempt intubation rate [risk ratio (RR) 1.20, 95% confidence interval (CI) 0.99 to 1.44] (6 trials, 568 participants), trauma risk (RR 0.83, 95% CI 0.67 to 1.03) (5 trials, 501 participants) as well as the overall risks of epistaxis (RR 0.58, 95% CI 0.26 to 1.31) (3 trials, 262 participants), sore throat (RR 0.90, 95% CI 0.70 to 1.17) (4 trials, 451 participants) and hoarseness (RR 0.71, 95% CI 0.44 to 1.14) (4 trials, 451 participants) between the two groups. However, the intubation time was slightly shorter (weighted mean difference −4.2 s, 95% CI −7.4 to −1.0 s) (8 trials, 759 participants) and the risks of severe epistaxis (RR 0.15, 95% CI 0.03 to 0.84) (3 trials, 262 participants) and overall difficulty in airway manipulation (RR 0.48, 95% CI 0.29 to 0.80) (8 trials, 647 participants) were lower in the PFT group than those in the standard polyvinylchloride group. Trial sequential analysis conclusively confirmed a shorter intubation time with PFT tubes than with standard polyvinylchloride tubes, whereas other intubation outcomes were inconclusive. CONCLUSION: The use of PFT tubes for airway manipulation was associated with a shorter intubation time compared with the standard polyvinylchloride tubes. The results of trial sequential analysis suggest the need for further trials and meta-analysis to compare other intubation outcomes associated with the two devices. TRIAL REGISTRATION: PROSPERO CRD42020197670. Abstract : Supplemental Digital Content is available in the text … (more)
- Is Part Of:
- European journal of anaesthesiology. Volume 38:Issue 8(2021)
- Journal:
- European journal of anaesthesiology
- Issue:
- Volume 38:Issue 8(2021)
- Issue Display:
- Volume 38, Issue 8 (2021)
- Year:
- 2021
- Volume:
- 38
- Issue:
- 8
- Issue Sort Value:
- 2021-0038-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-08
- Subjects:
- Anesthesiology -- Periodicals
Anesthesiology -- Periodicals
Anesthésiologie -- Périodiques
Anesthesiology
Periodicals
Electronic journals
617.96 - Journal URLs:
- http://journals.lww.com/ejanaesthesiology/pages/default.aspx ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-2346/issues ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=eja ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00003643-000000000-00000 ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0265-0215 ↗ - DOI:
- 10.1097/EJA.0000000000001539 ↗
- Languages:
- English
- ISSNs:
- 0265-0215
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.722200
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18929.xml