E-008 Virtual micro-catheter delivery simulation comparison between simulation and actual delivery. (22nd July 2019)
- Record Type:
- Journal Article
- Title:
- E-008 Virtual micro-catheter delivery simulation comparison between simulation and actual delivery. (22nd July 2019)
- Main Title:
- E-008 Virtual micro-catheter delivery simulation comparison between simulation and actual delivery
- Authors:
- Fujimura, S
Takao, H
Uchiyama, Y
Ono, H
Ishii, T
Okudaira, T
Ishibashi, T
Otani, K
Fukudome, K
Yamamoto, M
Murayama, Y - Abstract:
- Abstract : Introduction: To ensure safe and stable coil embolization for intracranial aneurysms, shaping the tip of the micro-catheter to be used is one of the most important factors. Therefore, if it was possible to simulate the micro-catheter delivery before procedure, we could understand where the micro-catheter tip would settle and whether the shaped geometry is optimized or not. We developed a virtual micro-catheter delivery simulation using the numerical simulation technique of finite element method (FEM). We validated the virtual micro-catheter delivery simulation by comparing the simulated results and an actual delivered micro-catheter path line. Materials and methods: We selected one middle sized internal carotid (ICA) artery aneurysm, which had performed successful coil embolization by a neurosurgeon (board certified, 15 years of experience). The 3D geometrical data of the artery and aneurysm before surgery were reconstructed from digital subtraction angiography data. The generated region ranged from the ICA cervical part to the bifurcation point of the middle cerebral (MCA) and anterior cerebral arteries (ACA). FEM was applied to simulate the virtual micro-catheter delivery. The virtual catheter was modeled using elastic Timoshenko beam elements and was inserted from the ICA under stress free condition at a speed of 10 mm/s. After the tip of the catheter was settled at the aneurysm, we exported the 2D images of the virtual catheter and artery from two differentAbstract : Introduction: To ensure safe and stable coil embolization for intracranial aneurysms, shaping the tip of the micro-catheter to be used is one of the most important factors. Therefore, if it was possible to simulate the micro-catheter delivery before procedure, we could understand where the micro-catheter tip would settle and whether the shaped geometry is optimized or not. We developed a virtual micro-catheter delivery simulation using the numerical simulation technique of finite element method (FEM). We validated the virtual micro-catheter delivery simulation by comparing the simulated results and an actual delivered micro-catheter path line. Materials and methods: We selected one middle sized internal carotid (ICA) artery aneurysm, which had performed successful coil embolization by a neurosurgeon (board certified, 15 years of experience). The 3D geometrical data of the artery and aneurysm before surgery were reconstructed from digital subtraction angiography data. The generated region ranged from the ICA cervical part to the bifurcation point of the middle cerebral (MCA) and anterior cerebral arteries (ACA). FEM was applied to simulate the virtual micro-catheter delivery. The virtual catheter was modeled using elastic Timoshenko beam elements and was inserted from the ICA under stress free condition at a speed of 10 mm/s. After the tip of the catheter was settled at the aneurysm, we exported the 2D images of the virtual catheter and artery from two different angles that were the same as the actual 2D angiographic images during embolization. We qualitatively and quantitatively compare the micro-catheter path line of the catheter by overlapping the simulated image and actual image. Results: The path lines of the simulated and actual catheters corresponded well to each other on the images from both angle (see the attached figure 1). To evaluate the results quantitatively, we calculated the area under the catheter path line curves from the simulation and actual delivery. On the images of both angles, the relative errors of the area were around 10%. Although the simulation had limitations including rigid artery and non-blood flow in the artery, we were able to obtain a validated catheter path line using our virtual micro-catheter delivery simulation. Conclusions: The simulated path line of the inserted virtual micro catheter showed good correlation with the actual catheter path line. This simulation may be applicable to optimize the shape of the micro catheter to ensure stable delivery during coil embolization. Disclosures: S. Fujimura: 1; C; JSPS KAKENHI Grant Number JP17J07496. H. Takao: None. Y. Uchiyama: None. H. Ono: None. T. Ishii: None. T. Okudaira: None. T. Ishibashi: None. K. Otani: None. K. Fukudome: None. M. Yamamoto: None. Y. Murayama: None. … (more)
- Is Part Of:
- Journal of neurointerventional surgery. Volume 11(2019)Supplement 1
- Journal:
- Journal of neurointerventional surgery
- Issue:
- Volume 11(2019)Supplement 1
- Issue Display:
- Volume 11, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 11
- Issue:
- 1
- Issue Sort Value:
- 2019-0011-0001-0000
- Page Start:
- A52
- Page End:
- A52
- Publication Date:
- 2019-07-22
- Subjects:
- Nervous system -- Surgery -- Periodicals
Cerebrovascular disease -- Surgery -- Periodicals
617.48 - Journal URLs:
- http://www.bmj.com/archive ↗
http://jnis.bmj.com/ ↗ - DOI:
- 10.1136/neurintsurg-2019-SNIS.83 ↗
- Languages:
- English
- ISSNs:
- 1759-8478
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18895.xml