E-112 How do clots respond to direct aspiration during interventional treatment of acute ischemic stroke. (22nd July 2019)
- Record Type:
- Journal Article
- Title:
- E-112 How do clots respond to direct aspiration during interventional treatment of acute ischemic stroke. (22nd July 2019)
- Main Title:
- E-112 How do clots respond to direct aspiration during interventional treatment of acute ischemic stroke
- Authors:
- Marosfoi, M
Strittmatter, L
Arslanian, R
Raskett, C
Gounis, M
Puri, A
Massari, F
De Macedo Rodrigues, K
Singh, J
Chueh, J - Abstract:
- Abstract : Introduction: Advances in pump design make aspiration patterns programmable, producing an infinite combination of cyclical aspiration profiles for clot removal during treatment of acute ischemic stroke (AIS). However, little is known about how clots respond to different aspiration patterns. The goal of this study is to assess the structural and mechanical changes of the clot under aspiration. It is our hypothesis that a decreased fibrin pore size correlates to a higher aspiration efficacy. Materials and methods: A fibrin-rich bovine clot was used to create an MCA occlusion in a patient-specific silicone model and underwent thromboaspiration via a 6F Sofia Plus catheter (MicroVention, Tustin, CA). Three sets of the retrieved clots were prepared for scanning electron microscopy (SEM) analysis, including clots lodged at the MCA without aspiration (control) as well as clots subjected to static (28 mmHg) or cyclic aspiration (amplitude: 18 to 27 mmHg) for 2 minutes (CLEAR TM Aspiration System, Insera Therapeutics, LLC, Sacramento, CA). All the clot samples were fixed, dehydrated and frozen fractured. Surfaces of the fractured clots were imaged at 20 Kx at four different locations to obtain pore-size estimates of fibrin networks using ImageJ. Dynamic mechanical analysis (DMA) was conducted to understand the viscoelastic behavior of the clots obtained from patients with AIS under cyclic loading conditions. Results: The fibrin-rich clot was corked in the distal tip of theAbstract : Introduction: Advances in pump design make aspiration patterns programmable, producing an infinite combination of cyclical aspiration profiles for clot removal during treatment of acute ischemic stroke (AIS). However, little is known about how clots respond to different aspiration patterns. The goal of this study is to assess the structural and mechanical changes of the clot under aspiration. It is our hypothesis that a decreased fibrin pore size correlates to a higher aspiration efficacy. Materials and methods: A fibrin-rich bovine clot was used to create an MCA occlusion in a patient-specific silicone model and underwent thromboaspiration via a 6F Sofia Plus catheter (MicroVention, Tustin, CA). Three sets of the retrieved clots were prepared for scanning electron microscopy (SEM) analysis, including clots lodged at the MCA without aspiration (control) as well as clots subjected to static (28 mmHg) or cyclic aspiration (amplitude: 18 to 27 mmHg) for 2 minutes (CLEAR TM Aspiration System, Insera Therapeutics, LLC, Sacramento, CA). All the clot samples were fixed, dehydrated and frozen fractured. Surfaces of the fractured clots were imaged at 20 Kx at four different locations to obtain pore-size estimates of fibrin networks using ImageJ. Dynamic mechanical analysis (DMA) was conducted to understand the viscoelastic behavior of the clots obtained from patients with AIS under cyclic loading conditions. Results: The fibrin-rich clot was corked in the distal tip of the aspiration catheter during clot retrieval. The average clot diameter measured proximally was 3.5 mm, 2.3 mm and 1.8 mm for the control, static and cyclic groups, respectively. Mechanical loading-unloading-reloading on the clot resulted in clot deformations; however, the changes in the clot dimension were less pronounced as the mechanical stimulus continued during the DMA tests. Clot deformation during aspiration was accompanied by a reduction in the average pore size in the fibrin-rich clot. The figure 1 demonstrates that the fibrin pore size measured from the proximal end of the clot was significantly reduced after aspiration when compared to the control clot (control: 857µm 2, cyclic: 434µm 2, static: 420 µm 2 ). No significant differences in fibrin pore size were observed between the cyclic and static groups; however, it should be noted that the smallest pore size measurement was found in the cyclic group. Conclusion: Applying cyclic or static aspiration to the fibrin-rich clot forms a denser fibrin mesh and results in clot stiffening. A comprehensive study is ongoing to study the structural changes of different clot models under aspiration at various frequencies and amplitudes. Disclosures: M. Marosfoi: 2; C; Stryker Neurovascular and InNeuroCo Inc. L. Strittmatter: None. R. Arslanian: None. C. Raskett: None. M. Gounis: 1; C; the National Institutes of Health, Israel Binational Science Foundation, Anaconda, Cerenovus, Cook Medical, Gentuity, Imperative Care, InNeuroCo, Magneto, Microvention, Medtronic Neurovascular, MIVI Neurosciences, Neuravi, Neurogami, Philips Healthcare, Rapid Medical, Route 92 Medical, Stryker Neurovascular, Syntheon, and the Wyss Institute. 2; C; Cerenovus, Imperative Care, MIVI Neurosciences, phenox, Route 92 Medical, Stryker Neurovascular. 4; C; Imperative Care and Neurogami. A. Puri: 1; C; Medtronic Neurovascular and Stryker Neurovascular. 2; C; Medtronic Neurovascular and Stryker Neurovascular. F. Massari: None. K. De Macedo Rodrigues: None. J. Singh: None. J. Chueh: 2; C; Stryker Neurovascular and InNeuroCo Inc. … (more)
- Is Part Of:
- Journal of neurointerventional surgery. Volume 11(2019)Supplement 1
- Journal:
- Journal of neurointerventional surgery
- Issue:
- Volume 11(2019)Supplement 1
- Issue Display:
- Volume 11, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 11
- Issue:
- 1
- Issue Sort Value:
- 2019-0011-0001-0000
- Page Start:
- A109
- Page End:
- A110
- Publication Date:
- 2019-07-22
- Subjects:
- Nervous system -- Surgery -- Periodicals
Cerebrovascular disease -- Surgery -- Periodicals
617.48 - Journal URLs:
- http://www.bmj.com/archive ↗
http://jnis.bmj.com/ ↗ - DOI:
- 10.1136/neurintsurg-2019-SNIS.187 ↗
- Languages:
- English
- ISSNs:
- 1759-8478
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18894.xml