Operative choice for displaced proximal humeral fractures in adolescents with open visible physis: A comparative study of external fixator vs. Kirschner wire. Issue 8 (August 2021)
- Record Type:
- Journal Article
- Title:
- Operative choice for displaced proximal humeral fractures in adolescents with open visible physis: A comparative study of external fixator vs. Kirschner wire. Issue 8 (August 2021)
- Main Title:
- Operative choice for displaced proximal humeral fractures in adolescents with open visible physis: A comparative study of external fixator vs. Kirschner wire
- Authors:
- Li, Jin
Rai, Saroj
Qian, Huabing
Tang, Xin
Liu, Ruikang
Hong, Pan - Abstract:
- Abstract: Background: For adolescents with severely displaced proximal humeral fracture (PHF), surgery is a good choice yielding excellent outcomes, and Kirchner wire (KW) is a cost-effective choice for fixation. Purpose of this study is to compare the clinical outcomes of external fixator (EF) and KW for the treatment of PHF in adolescents. Methods: Patients of PHF operated at our institute, from January 2008 to January 2016, were reviewed retrospectively. Demographic data, including sex, age at the time of surgery, operated side, and hardware choice, were collected from the hospital database. Preoperative radiographs were reviewed and classified according to Neer-Horwitz classification. Shoulder function was evaluated at the last follow-up using the American Shoulder and Elbow Surgeons (ASES) score. Complications, including infection, malunion, nonunion, stiffness of the shoulder joint, and failure of fixation were also recorded. Results: Thirty-five patients, including 23 males and 12 females, were included in the EF group, whereas 40 patients, including 25 males and 15 females, were included in the KW group ( P = 0.867). The average age of patients in the EF group was 13.3 ± 1.7 years, and that of KW was 13.6 ± 1.8 years ( P = 0.409). Patients in both groups were followed-up for at least 12 months. The operative time in the EF group (42.4 ± 11.2 min) was significantly shorter than those in the KW group (54 ± 13.6 min) ( P < 0.001). The frequency of fluoroscopy in theAbstract: Background: For adolescents with severely displaced proximal humeral fracture (PHF), surgery is a good choice yielding excellent outcomes, and Kirchner wire (KW) is a cost-effective choice for fixation. Purpose of this study is to compare the clinical outcomes of external fixator (EF) and KW for the treatment of PHF in adolescents. Methods: Patients of PHF operated at our institute, from January 2008 to January 2016, were reviewed retrospectively. Demographic data, including sex, age at the time of surgery, operated side, and hardware choice, were collected from the hospital database. Preoperative radiographs were reviewed and classified according to Neer-Horwitz classification. Shoulder function was evaluated at the last follow-up using the American Shoulder and Elbow Surgeons (ASES) score. Complications, including infection, malunion, nonunion, stiffness of the shoulder joint, and failure of fixation were also recorded. Results: Thirty-five patients, including 23 males and 12 females, were included in the EF group, whereas 40 patients, including 25 males and 15 females, were included in the KW group ( P = 0.867). The average age of patients in the EF group was 13.3 ± 1.7 years, and that of KW was 13.6 ± 1.8 years ( P = 0.409). Patients in both groups were followed-up for at least 12 months. The operative time in the EF group (42.4 ± 11.2 min) was significantly shorter than those in the KW group (54 ± 13.6 min) ( P < 0.001). The frequency of fluoroscopy in the EF group (12 ± 2.4 times) was significantly less than those in the KW group (17 ± 2.8 times ( P < 0.001). The rate of open reduction was significantly higher in KW (35%) group than those in the EF group (0%) ( P < 0.001). There was no case of nonunion and malunion in both groups. Conclusion: External fixator is superior to Kirschner wire in the treatment of proximal humeral fractures in adolescents with shorter operative time and lower rate of open reduction with comparable clinical outcomes. … (more)
- Is Part Of:
- Injury. Volume 52:Issue 8(2021)
- Journal:
- Injury
- Issue:
- Volume 52:Issue 8(2021)
- Issue Display:
- Volume 52, Issue 8 (2021)
- Year:
- 2021
- Volume:
- 52
- Issue:
- 8
- Issue Sort Value:
- 2021-0052-0008-0000
- Page Start:
- 2279
- Page End:
- 2284
- Publication Date:
- 2021-08
- Subjects:
- External fixator -- Kirschner wire -- Proximal humeral fracture -- Adolescent
Wounds and injuries -- Surgery -- Periodicals
Accidents -- Periodicals
Wounds and Injuries -- surgery -- Periodicals
Lésions et blessures -- Chirurgie -- Périodiques
Electronic journals
Electronic journals
617.1 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00201383 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00201383 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00201383 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.injury.2021.03.015 ↗
- Languages:
- English
- ISSNs:
- 0020-1383
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4514.400000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18874.xml