Percutaneous transluminal angioplasty using the novel drug-coated balloon catheter SeQuent Please NEO for the treatment of symptomatic intracranial severe stenosis: feasibility and safety study. (10th November 2018)
- Record Type:
- Journal Article
- Title:
- Percutaneous transluminal angioplasty using the novel drug-coated balloon catheter SeQuent Please NEO for the treatment of symptomatic intracranial severe stenosis: feasibility and safety study. (10th November 2018)
- Main Title:
- Percutaneous transluminal angioplasty using the novel drug-coated balloon catheter SeQuent Please NEO for the treatment of symptomatic intracranial severe stenosis: feasibility and safety study
- Authors:
- Gruber, Philipp
Braun, Christina
Kahles, Timo
Hlavica, Martin
Anon, Javier
Diepers, Michael
Nedeltchev, Krassen
Berberat, Jatta
Remonda, Luca - Abstract:
- Abstract : Objectives: Intracranial arteriosclerotic disease is a relevant cause of ischemic stroke worldwide with a high recurrence rate despite best medical treatment. Following the SAMMPRIS trial, endovascular treatment has remained a second-line therapy. Meanwhile, there has been significant advances in device technology. SeQuent Please NEO is a novel polymer-free, drug-coated (paclitaxel/iopromide) balloon (DCB) primarily designed for cardiology. Because of its high flexibility and pushability, it may also be suitable for intracranial use. The aim of this study was to assess the feasibility and safety of SeQuent Please NEO DCB in symptomatic intracranial severe stenosis. Methods: A single-center retrospective cohort study of patients with symptomatic intracranial severe stenosis treated with SeQuent Please NEO DCB was performed at a tertiary stroke center. Results: Ten patients (all men, median age 73 years (IQR 69–77)) were included. Median pre-treatment stenosis grade was 78% (IQR 75–80%) with four internal carotid artery, two mid-basilar artery, and four vertebral artery lesions. Median post-treatment stenosis grade was 50% (IQR 45–53%). Successful angioplasty was achieved in all cases without technical failure. There were no cases of peri-procedural reocclusion and no deaths at median follow-up of 3 months (IQR 2–3). Conclusion: In this pilot study, SeQuent Please NEO DCB was feasible and safe in the treatment of symptomatic intracranial severe stenosis. It mightAbstract : Objectives: Intracranial arteriosclerotic disease is a relevant cause of ischemic stroke worldwide with a high recurrence rate despite best medical treatment. Following the SAMMPRIS trial, endovascular treatment has remained a second-line therapy. Meanwhile, there has been significant advances in device technology. SeQuent Please NEO is a novel polymer-free, drug-coated (paclitaxel/iopromide) balloon (DCB) primarily designed for cardiology. Because of its high flexibility and pushability, it may also be suitable for intracranial use. The aim of this study was to assess the feasibility and safety of SeQuent Please NEO DCB in symptomatic intracranial severe stenosis. Methods: A single-center retrospective cohort study of patients with symptomatic intracranial severe stenosis treated with SeQuent Please NEO DCB was performed at a tertiary stroke center. Results: Ten patients (all men, median age 73 years (IQR 69–77)) were included. Median pre-treatment stenosis grade was 78% (IQR 75–80%) with four internal carotid artery, two mid-basilar artery, and four vertebral artery lesions. Median post-treatment stenosis grade was 50% (IQR 45–53%). Successful angioplasty was achieved in all cases without technical failure. There were no cases of peri-procedural reocclusion and no deaths at median follow-up of 3 months (IQR 2–3). Conclusion: In this pilot study, SeQuent Please NEO DCB was feasible and safe in the treatment of symptomatic intracranial severe stenosis. It might represent a promising alternative to medical treatment in selected cases. … (more)
- Is Part Of:
- Journal of neurointerventional surgery. Volume 11:Number 7(2019)
- Journal:
- Journal of neurointerventional surgery
- Issue:
- Volume 11:Number 7(2019)
- Issue Display:
- Volume 11, Issue 7 (2019)
- Year:
- 2019
- Volume:
- 11
- Issue:
- 7
- Issue Sort Value:
- 2019-0011-0007-0000
- Page Start:
- 719
- Page End:
- 722
- Publication Date:
- 2018-11-10
- Subjects:
- angioplasty -- atherosclerosis -- balloon -- stroke
Nervous system -- Surgery -- Periodicals
Cerebrovascular disease -- Surgery -- Periodicals
617.48 - Journal URLs:
- http://www.bmj.com/archive ↗
http://jnis.bmj.com/ ↗ - DOI:
- 10.1136/neurintsurg-2018-014378 ↗
- Languages:
- English
- ISSNs:
- 1759-8478
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18891.xml