Medina embolization device for the treatment of intracranial aneurysms: 18 months' angiographic results. (24th November 2018)
- Record Type:
- Journal Article
- Title:
- Medina embolization device for the treatment of intracranial aneurysms: 18 months' angiographic results. (24th November 2018)
- Main Title:
- Medina embolization device for the treatment of intracranial aneurysms: 18 months' angiographic results
- Authors:
- Haffaf, Idriss
Clarençon, Frédéric
Shotar, Eimad
Rolla-Bigliani, Claudia
Vande Perre, Saskia
Mathon, Bertrand
Drir, Mehdi
Sourour, Nader-Antoine - Abstract:
- Abstract : Background and purpose: The Medina embolization device (MED) is a new flow disruption device combining the design of a detachable coil with an intrasaccular flow disrupter. Safety and short-term angiographic effectiveness of this device have recently been reported. However, long-term angiographic results are lacking. We report herein the 18 months' angiographic outcome in patients treated for a wide-neck intracranial aneurysm with the MED. Materials and methods: Nineteen patients (17 female, mean age 50 years) with 20 wide-neck intracranial aneurysms (six ruptured; 14 unruptured) were treated by the MED between January 2015 and June 2016. Procedure-related complications were systematically recorded; discharge and 6–9 months' follow-up modified Rankin Scale scores were assessed. Angiographic mid-term and long-term follow-up were performed with a mean delay of 6.4±1.5 months (n=16 aneurysms) and 17.7±4.2 months (n=15 aneurysms), respectively. Occlusion rates were evaluated after the procedure and at the mid-term and long-term follow-up using the Roy-Raymond scale. Results: Embolization with the MED was feasible in all except two cases (2/20, 10%). One per-procedural perforation was recorded (1/20, 5%) and one MED deployment failed because of the aneurysm's shape (1/20, 5%). Three cases of thromboembolic complications were observed (3/20, 15%). Only one thromboembolic complication was responsible for clinical sequelae. Grade A occlusion rate was 61% (11/18) after theAbstract : Background and purpose: The Medina embolization device (MED) is a new flow disruption device combining the design of a detachable coil with an intrasaccular flow disrupter. Safety and short-term angiographic effectiveness of this device have recently been reported. However, long-term angiographic results are lacking. We report herein the 18 months' angiographic outcome in patients treated for a wide-neck intracranial aneurysm with the MED. Materials and methods: Nineteen patients (17 female, mean age 50 years) with 20 wide-neck intracranial aneurysms (six ruptured; 14 unruptured) were treated by the MED between January 2015 and June 2016. Procedure-related complications were systematically recorded; discharge and 6–9 months' follow-up modified Rankin Scale scores were assessed. Angiographic mid-term and long-term follow-up were performed with a mean delay of 6.4±1.5 months (n=16 aneurysms) and 17.7±4.2 months (n=15 aneurysms), respectively. Occlusion rates were evaluated after the procedure and at the mid-term and long-term follow-up using the Roy-Raymond scale. Results: Embolization with the MED was feasible in all except two cases (2/20, 10%). One per-procedural perforation was recorded (1/20, 5%) and one MED deployment failed because of the aneurysm's shape (1/20, 5%). Three cases of thromboembolic complications were observed (3/20, 15%). Only one thromboembolic complication was responsible for clinical sequelae. Grade A occlusion rate was 61% (11/18) after the procedure, 75% at 6 months' follow-up (12/16), and 80% (12/15) at long-term follow-up. Two cases (2/18, 11%) of recanalization at mid-term were documented angiographically. No recanalization occurred between the mid-term and long-term follow-up. Conclusion: MED is a hybrid embolization device, combining properties of a conventional coil with those of an intrasaccular flow disrupter. Our series focusing on long-term angiographic follow-up shows a satisfactory long-term occlusion rate. Larger series with longer angiographic follow-up times are warranted to confirm these preliminary results. … (more)
- Is Part Of:
- Journal of neurointerventional surgery. Volume 11:Number 5(2019)
- Journal:
- Journal of neurointerventional surgery
- Issue:
- Volume 11:Number 5(2019)
- Issue Display:
- Volume 11, Issue 5 (2019)
- Year:
- 2019
- Volume:
- 11
- Issue:
- 5
- Issue Sort Value:
- 2019-0011-0005-0000
- Page Start:
- 516
- Page End:
- 522
- Publication Date:
- 2018-11-24
- Subjects:
- aneurysm -- device -- neck
Nervous system -- Surgery -- Periodicals
Cerebrovascular disease -- Surgery -- Periodicals
617.48 - Journal URLs:
- http://www.bmj.com/archive ↗
http://jnis.bmj.com/ ↗ - DOI:
- 10.1136/neurintsurg-2018-014110 ↗
- Languages:
- English
- ISSNs:
- 1759-8478
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18877.xml