Technical Note: 4D robust optimization in small spot intensity‐modulated proton therapy (IMPT) for distal esophageal carcinoma. Issue 8 (24th June 2021)
- Record Type:
- Journal Article
- Title:
- Technical Note: 4D robust optimization in small spot intensity‐modulated proton therapy (IMPT) for distal esophageal carcinoma. Issue 8 (24th June 2021)
- Main Title:
- Technical Note: 4D robust optimization in small spot intensity‐modulated proton therapy (IMPT) for distal esophageal carcinoma
- Authors:
- Feng, Hongying
Shan, Jie
Ashman, Jonathan B.
Rule, William G.
Bhangoo, Ronik S.
Yu, Nathan Y.
Chiang, Jennifer
Fatyga, Mirek
Wong, William W.
Schild, Steven E.
Sio, Terence T.
Liu, Wei - Abstract:
- Abstract : Purpose: To compare the dosimetric performances of small‐spot three‐dimensional (3D) and four‐dimensional (4D) robustly optimized intensity‐modulated proton (IMPT) plans in the presence of uncertainties and interplay effect simultaneously for distal esophageal carcinoma. Method and Materials: Thirteen (13) patients were selected and re‐planned with small‐spot ( σ ~ 2–6 mm) 3D and 4D robust optimization in IMPT, respectively. The internal clinical target volumes (CTVhigh3d, CTVlow3d ) were used in 3D robust optimization. Different CTVs (CTVhigh4d, CTVlow4d ) were generated by subtracting an inner margin of the motion amplitudes in three cardinal directions from the internal CTVs and used in 4D robust optimization. All patients were prescribed the same dose to CTVs (50 Gy[RBE] for CTVhigh3d /CTVhigh4d and 45 Gy[RBE] for CTVlow3d /CTVlow4d ). Dose–volume histogram (DVH) indices were calculated to assess plan quality. Comprehensive plan robustness evaluations that consisted of 300 perturbed scenarios (10 different motion patterns to consider irregular motion (sampled from a Gaussian distribution) and 30 different uncertainties scenarios (sampled from a 4D uniform distribution) combined), were performed to quantify robustness to uncertainties and interplay effect simultaneously. Wilcoxon signed‐rank test was used for statistical analysis. Results: Compared to 3D robustly optimized plans, 4D robustly optimized plans had statistically improved target coverage and betterAbstract : Purpose: To compare the dosimetric performances of small‐spot three‐dimensional (3D) and four‐dimensional (4D) robustly optimized intensity‐modulated proton (IMPT) plans in the presence of uncertainties and interplay effect simultaneously for distal esophageal carcinoma. Method and Materials: Thirteen (13) patients were selected and re‐planned with small‐spot ( σ ~ 2–6 mm) 3D and 4D robust optimization in IMPT, respectively. The internal clinical target volumes (CTVhigh3d, CTVlow3d ) were used in 3D robust optimization. Different CTVs (CTVhigh4d, CTVlow4d ) were generated by subtracting an inner margin of the motion amplitudes in three cardinal directions from the internal CTVs and used in 4D robust optimization. All patients were prescribed the same dose to CTVs (50 Gy[RBE] for CTVhigh3d /CTVhigh4d and 45 Gy[RBE] for CTVlow3d /CTVlow4d ). Dose–volume histogram (DVH) indices were calculated to assess plan quality. Comprehensive plan robustness evaluations that consisted of 300 perturbed scenarios (10 different motion patterns to consider irregular motion (sampled from a Gaussian distribution) and 30 different uncertainties scenarios (sampled from a 4D uniform distribution) combined), were performed to quantify robustness to uncertainties and interplay effect simultaneously. Wilcoxon signed‐rank test was used for statistical analysis. Results: Compared to 3D robustly optimized plans, 4D robustly optimized plans had statistically improved target coverage and better sparing of lungs and heart (heart Dmean, P = 0.001; heart V30Gy[RBE], P = 0.001) in the nominal scenario. 4D robustly optimized plans had better robustness in target dose coverage (CTVhigh4d V100%, P = 0.002) and the protection of lungs and heart (heart Dmean, P = 0.001; heart V30Gy[RBE], P = 0.001) when uncertainties and interplay effect were considered simultaneously. Conclusions: Even with small spots in IMPT, 4D robust optimization outperformed 3D robust optimization in terms of normal tissue protection and robustness to uncertainties and interplay effect simultaneously. Our findings support the use of 4D robust optimization to treat distal esophageal carcinoma with small spots in IMPT. … (more)
- Is Part Of:
- Medical physics. Volume 48:Issue 8(2021)
- Journal:
- Medical physics
- Issue:
- Volume 48:Issue 8(2021)
- Issue Display:
- Volume 48, Issue 8 (2021)
- Year:
- 2021
- Volume:
- 48
- Issue:
- 8
- Issue Sort Value:
- 2021-0048-0008-0000
- Page Start:
- 4636
- Page End:
- 4647
- Publication Date:
- 2021-06-24
- Subjects:
- 4D robust optimization -- distal esophageal carcinoma -- intensity‐modulated proton therapy -- interplay effect -- small spots
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.15003 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18888.xml