Satisfaction with and reliability of in-hospital video-EEG monitoring systems in epilepsy diagnosis – A German multicenter experience. Issue 9 (September 2021)
- Record Type:
- Journal Article
- Title:
- Satisfaction with and reliability of in-hospital video-EEG monitoring systems in epilepsy diagnosis – A German multicenter experience. Issue 9 (September 2021)
- Main Title:
- Satisfaction with and reliability of in-hospital video-EEG monitoring systems in epilepsy diagnosis – A German multicenter experience
- Authors:
- Willems, Laurent M.
Baier, Hartmut
Bien, Christian G.
Bösebeck, Frank
Dümpelmann, Matthias
Hamer, Hajo M.
Kellinghaus, Christoph
Knake, Susanne
Schreiber, Melanie
Staack, Anke Maren
Surges, Rainer
Tergau, Frithjof
von Podewils, Felix
Weber, Yvonne
Wehner, Tim
Winter, Yaroslav
Philipp Zöllner, Johann
Strzelczyk, Adam
Rosenow, Felix - Abstract:
- Highlights: Satisfaction with video-electroencephalography-monitoring systems (VEMS) at German epilepsy centers is low. Diagnosis is jeopardized in approximately every 10th patient due to hardware or software errors. Improvements in system stability and customer service are urgently needed. Abstract: Objective: To analyze satisfaction with and reliability of video-electroencephalography-monitoring systems (VEMS) in epilepsy diagnostics. Methods: A survey was conducted between December 2020 and January 2021 among German epilepsy centers using well-established customer satisfaction (CS) and quality assurance metrics. Results: Among 16 participating centers, CS with VEMS was low, with only 13% of customers actively recommending their system. Only 50% of users were satisfied with the overall performance of their VEMS, and a low 18% were satisfied with the manufacturer's customer service. User interface, software stability, lack of regular updates, and missing customer-oriented improvements were reported as frequent problems jeopardizing diagnosis in approximately every 10th patient. The greatest potential for improvement was identified for software and hardware stability as well as customer service. Conclusion: Satisfaction with VEMS and their customer service was low, and diagnostics were regularly affected by software or hardware errors. Even if this can be partly explained by the technical complexity of VEMS, there is an urgent need for improvements with regard to theHighlights: Satisfaction with video-electroencephalography-monitoring systems (VEMS) at German epilepsy centers is low. Diagnosis is jeopardized in approximately every 10th patient due to hardware or software errors. Improvements in system stability and customer service are urgently needed. Abstract: Objective: To analyze satisfaction with and reliability of video-electroencephalography-monitoring systems (VEMS) in epilepsy diagnostics. Methods: A survey was conducted between December 2020 and January 2021 among German epilepsy centers using well-established customer satisfaction (CS) and quality assurance metrics. Results: Among 16 participating centers, CS with VEMS was low, with only 13% of customers actively recommending their system. Only 50% of users were satisfied with the overall performance of their VEMS, and a low 18% were satisfied with the manufacturer's customer service. User interface, software stability, lack of regular updates, and missing customer-oriented improvements were reported as frequent problems jeopardizing diagnosis in approximately every 10th patient. The greatest potential for improvement was identified for software and hardware stability as well as customer service. Conclusion: Satisfaction with VEMS and their customer service was low, and diagnostics were regularly affected by software or hardware errors. Even if this can be partly explained by the technical complexity of VEMS, there is an urgent need for improvements with regard to the reliability and durability of system components as well as signal synchrony and data management. Significance: This analysis highlights low consumer satisfaction of users with VEMS and uncovers frequent problems and potential for improvement. … (more)
- Is Part Of:
- Clinical neurophysiology. Volume 132:Issue 9(2021)
- Journal:
- Clinical neurophysiology
- Issue:
- Volume 132:Issue 9(2021)
- Issue Display:
- Volume 132, Issue 9 (2021)
- Year:
- 2021
- Volume:
- 132
- Issue:
- 9
- Issue Sort Value:
- 2021-0132-0009-0000
- Page Start:
- 2317
- Page End:
- 2322
- Publication Date:
- 2021-09
- Subjects:
- EEG -- Medical technology -- Telemedicine -- Safety -- Quality
CES customer effort score -- CS customer satisfaction -- CSAT customer satisfaction score -- EEG electroencephalogram -- EU European Union -- GDPR General Data Protection Regulation -- GB gigabyte -- HIS hospital information system -- HIT health information technology -- LOS length of stay -- LS Likert Scale -- MD medical doctors/physicians -- MTA medical technical assistant -- NPS net promoter score -- TB terabyte -- TGW things gone wrong metric -- VEM video-EEG-monitoring -- VEMS video-EEG-monitoring system
Neurophysiology -- Periodicals
Electroencephalography -- Periodicals
Electromyography -- Periodicals
Neurology -- Periodicals
612.8 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13882457 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinph.2021.04.020 ↗
- Languages:
- English
- ISSNs:
- 1388-2457
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.310645
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18885.xml