An integrated framework for evaluation on typical ECG-derived respiration waveform extraction and respiration. (August 2021)
- Record Type:
- Journal Article
- Title:
- An integrated framework for evaluation on typical ECG-derived respiration waveform extraction and respiration. (August 2021)
- Main Title:
- An integrated framework for evaluation on typical ECG-derived respiration waveform extraction and respiration
- Authors:
- Dong, Kejun
Zhao, Li
Cai, Zhipeng
Li, Yuwen
Li, Jianqing
Liu, Chengyu - Abstract:
- Abstract: Objective: ECG-derived respiration (EDR) methods have been developed during the past decades to obtain respiration-relevant information. However, it is still necessary to compare the performance of these methods under uniform conditions for reasonable application. Approach : In this paper, the performance of 10 feature-based EDR methods was evaluated comprehensively on three aspects: sampling rate, noise, and window length. The Fantasia database was used in this study, as it contained ECG signals and simultaneously measured respiration signals. The performance was quantified by two parameters: waveform correlation and breathing rate (BR) errors. Main results : The BR errors of AM area, AM QR, AM R were all below 2 beats per minute (bpm) when the sampling rate was above 150 Hz, while they decreased sharply by about 60% when the sampling rate was below 150 Hz. FM RR presented stable performance with an error below 2 bpm at different sampling rates. The effect of noise was obviously found in amplitude-based EDR methods, with the maximum decreased by about 40% in waveform correlation. For all EDR methods, significant increase of BR errors occurred with the window shorting from 32 s to 16 s in the frequency-based technique. In addition, about 30%–40% of the window cannot obtain the BR error, calculated based on the time-based technique, within an 8 s window. Significance : We proposed a comprehensive and integrated evaluation on typical ECG-derived respiration waveformAbstract: Objective: ECG-derived respiration (EDR) methods have been developed during the past decades to obtain respiration-relevant information. However, it is still necessary to compare the performance of these methods under uniform conditions for reasonable application. Approach : In this paper, the performance of 10 feature-based EDR methods was evaluated comprehensively on three aspects: sampling rate, noise, and window length. The Fantasia database was used in this study, as it contained ECG signals and simultaneously measured respiration signals. The performance was quantified by two parameters: waveform correlation and breathing rate (BR) errors. Main results : The BR errors of AM area, AM QR, AM R were all below 2 beats per minute (bpm) when the sampling rate was above 150 Hz, while they decreased sharply by about 60% when the sampling rate was below 150 Hz. FM RR presented stable performance with an error below 2 bpm at different sampling rates. The effect of noise was obviously found in amplitude-based EDR methods, with the maximum decreased by about 40% in waveform correlation. For all EDR methods, significant increase of BR errors occurred with the window shorting from 32 s to 16 s in the frequency-based technique. In addition, about 30%–40% of the window cannot obtain the BR error, calculated based on the time-based technique, within an 8 s window. Significance : We proposed a comprehensive and integrated evaluation on typical ECG-derived respiration waveform extraction and respiration rate calculation, providing references for algorithm selection based on different requirements. … (more)
- Is Part Of:
- Computers in biology and medicine. Volume 135(2021)
- Journal:
- Computers in biology and medicine
- Issue:
- Volume 135(2021)
- Issue Display:
- Volume 135, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 135
- Issue:
- 2021
- Issue Sort Value:
- 2021-0135-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-08
- Subjects:
- ECG-Derived respiration breathing rate waveform correlation a comprehensive and integrated evaluation
Medicine -- Data processing -- Periodicals
Biology -- Data processing -- Periodicals
610.285 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00104825/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.compbiomed.2021.104593 ↗
- Languages:
- English
- ISSNs:
- 0010-4825
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.880000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18878.xml