Capacitor placement and sizing to minimize losses in a radial distribution network considering uncertainty using modified affine arithmetic division. (September 2021)
- Record Type:
- Journal Article
- Title:
- Capacitor placement and sizing to minimize losses in a radial distribution network considering uncertainty using modified affine arithmetic division. (September 2021)
- Main Title:
- Capacitor placement and sizing to minimize losses in a radial distribution network considering uncertainty using modified affine arithmetic division
- Authors:
- Adusumilli, Bala Surendra
Raj, Vinod
Adusumilli, Vijaya Bhaskar - Abstract:
- Abstract: In a distribution system, load and distributed generation connected to a feeder are subject to uncertainty. Conventional capacitor placement and sizing methods do not consider uncertainty in power injections, due to which the results may be erroneous. In literature, affine arithmetic (AA) is one of the tools used for incorporating uncertainty in power system analysis. However, conventional division operation in AA gives rise to extra noise terms in the resulting affine form, which are not due to the actual uncertainty sources but are due to the nonaffine operations. The present work incorporates modified AA division which does not generate any additional noises, thereby improving the accuracy. Buses in the distribution network are ranked in decreasing order of rate of change of active power loss in line with respect to the change in the effective reactive power flow in that line. The top three ranked buses are chosen as candidate buses for capacitor connection. The required affine reactive current injection at the candidate buses is calculated, and the corresponding affine capacitive kVAR required is obtained through modified AA-based backward/forward sweep (BFS) power flow analysis. The intervals for the cost incurred in losses, voltage profiles with and without capacitor are calculated, and savings for capacitor connected system is calculated. Switchable capacitors are used for reactive power injection. The proposed method is tested on 15, 33 and 118 bus radialAbstract: In a distribution system, load and distributed generation connected to a feeder are subject to uncertainty. Conventional capacitor placement and sizing methods do not consider uncertainty in power injections, due to which the results may be erroneous. In literature, affine arithmetic (AA) is one of the tools used for incorporating uncertainty in power system analysis. However, conventional division operation in AA gives rise to extra noise terms in the resulting affine form, which are not due to the actual uncertainty sources but are due to the nonaffine operations. The present work incorporates modified AA division which does not generate any additional noises, thereby improving the accuracy. Buses in the distribution network are ranked in decreasing order of rate of change of active power loss in line with respect to the change in the effective reactive power flow in that line. The top three ranked buses are chosen as candidate buses for capacitor connection. The required affine reactive current injection at the candidate buses is calculated, and the corresponding affine capacitive kVAR required is obtained through modified AA-based backward/forward sweep (BFS) power flow analysis. The intervals for the cost incurred in losses, voltage profiles with and without capacitor are calculated, and savings for capacitor connected system is calculated. Switchable capacitors are used for reactive power injection. The proposed method is tested on 15, 33 and 118 bus radial distribution systems. The results show that the proposed modified AA method is accurate than existing interval arithmetic-based method. … (more)
- Is Part Of:
- Sustainable energy, grids and networks. Volume 27(2021)
- Journal:
- Sustainable energy, grids and networks
- Issue:
- Volume 27(2021)
- Issue Display:
- Volume 27, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 27
- Issue:
- 2021
- Issue Sort Value:
- 2021-0027-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-09
- Subjects:
- Affine arithmetic -- Backward/forward sweep power flow -- Capacitor placement -- Uncertainty -- Loss minimization
Renewable energy sources -- Periodicals
Smart power grids -- Periodicals
Electric power systems -- Periodicals
333.794 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23524677/ ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.segan.2021.100492 ↗
- Languages:
- English
- ISSNs:
- 2352-4677
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18878.xml