Comparison of respiratory-triggered 3D MR cholangiopancreatography and breath-hold compressed-sensing 3D MR cholangiopancreatography at 1.5 T and 3 T and impact of individual factors on image quality. Issue 142 (September 2021)
- Record Type:
- Journal Article
- Title:
- Comparison of respiratory-triggered 3D MR cholangiopancreatography and breath-hold compressed-sensing 3D MR cholangiopancreatography at 1.5 T and 3 T and impact of individual factors on image quality. Issue 142 (September 2021)
- Main Title:
- Comparison of respiratory-triggered 3D MR cholangiopancreatography and breath-hold compressed-sensing 3D MR cholangiopancreatography at 1.5 T and 3 T and impact of individual factors on image quality
- Authors:
- Blaise, Hélène
Remen, Thomas
Ambarki, Khalid
Weiland, Elisabeth
Kuehn, Bernd
Orry, Xavier
Laurent, Valérie - Abstract:
- Highlights: At 3 T, BH-CS-MRCP offers better image quality than conventional acquisition with respiratory-triggering. At 1.5 T, aside from sharpness, BH-CS-MRCP does not improve image quality. At 3 T image quality is not affected by individual patient characteristics. At 1.5 T, ascites on BH-CS-MRCP and high BMI on STD-MRCP are associated with degradation of image quality. Abstract: Purpose: To evaluate the image quality of an accelerated compressed-sensing single-breath-hold 3D magnetic resonance cholangiopancreatography (BH-CS-MRCP) prototype sequence compared to the standard 3D sequence with respiratory triggering (STD-MRCP) at 1.5 T and 3 T. To assess the individual factors that can affect image quality. Method: This is a retrospective analysis. Both sequences (BH-CS-MRCP and STD-MRCP) were performed in 200 patients at 1.5 T and 200 patients at 3 T. Overall image quality and the visualization of the bilio-pancreatic ducts were rated on a 5-point scale. Image sharpness and background suppression were rated on a 4-point scale. A double reading was performed in 50 patients to assess the inter-observer reproducibility. Individual characteristics studied were gender, age, BMI, ascites, abdominal surface and breath-hold quality. Results: At 1.5 T, BH-CS-MRCP was inferior to STD-MRCP in terms of overall quality (p = 0.0046), background suppression (p < 0.0001), visualization of the cystic duct (p < 0.0001), the right bile duct (p = 0.0008), the left bile duct (p = 0.0152), andHighlights: At 3 T, BH-CS-MRCP offers better image quality than conventional acquisition with respiratory-triggering. At 1.5 T, aside from sharpness, BH-CS-MRCP does not improve image quality. At 3 T image quality is not affected by individual patient characteristics. At 1.5 T, ascites on BH-CS-MRCP and high BMI on STD-MRCP are associated with degradation of image quality. Abstract: Purpose: To evaluate the image quality of an accelerated compressed-sensing single-breath-hold 3D magnetic resonance cholangiopancreatography (BH-CS-MRCP) prototype sequence compared to the standard 3D sequence with respiratory triggering (STD-MRCP) at 1.5 T and 3 T. To assess the individual factors that can affect image quality. Method: This is a retrospective analysis. Both sequences (BH-CS-MRCP and STD-MRCP) were performed in 200 patients at 1.5 T and 200 patients at 3 T. Overall image quality and the visualization of the bilio-pancreatic ducts were rated on a 5-point scale. Image sharpness and background suppression were rated on a 4-point scale. A double reading was performed in 50 patients to assess the inter-observer reproducibility. Individual characteristics studied were gender, age, BMI, ascites, abdominal surface and breath-hold quality. Results: At 1.5 T, BH-CS-MRCP was inferior to STD-MRCP in terms of overall quality (p = 0.0046), background suppression (p < 0.0001), visualization of the cystic duct (p < 0.0001), the right bile duct (p = 0.0008), the left bile duct (p = 0.0152), and the main pancreatic duct (p < 0.0001). However, BH-CS-MRCP was sharper than STD-MRCP (p = 0.028). At 3 T, BH-CS-MRCP was superior to STD-MRCP for overall quality (p < 0.0001), sharpness (p < 0.0001), and visualization of the bilio-pancreatic ducts (p < 0.0001). Background signal was conversely better suppressed in STD-MRCP (p < 0.0001). At 1.5 T, the volume of ascites was inversely correlated with image quality for BH-CS-MRCP while BMI was inversely correlated with image quality for STD-MRCP. Breath-hold quality was correlated with image quality for BH-CS-MRCP at 1.5 T and 3 T. Conclusion: BH-CS-MRCP is feasible in clinical routine at 1.5 and 3 T, yielding significantly better perceived image quality at 3 T but not at 1.5 T. BH-CS-MRCP appears to be influenced by ascites whereas STD-MRCP is influenced by BMI at 1.5 T. This study was approved by the Ethics Review Board for Research in Medical Imaging (IRB: CRM-2003–065). … (more)
- Is Part Of:
- European journal of radiology. Issue 142(2021)
- Journal:
- European journal of radiology
- Issue:
- Issue 142(2021)
- Issue Display:
- Volume 142, Issue 142 (2021)
- Year:
- 2021
- Volume:
- 142
- Issue:
- 142
- Issue Sort Value:
- 2021-0142-0142-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-09
- Subjects:
- Magnetic resonance imaging -- 3D magnetic resonance cholangiopancreatography -- Compressed-sensing -- Breath-hold -- 1.5T -- 3T
BH breath-hold -- BMI body mass index -- CS compressed-sensing -- GRAPPA generalized auto-calibrating partially parallel acquisition -- HASTE half-Fourier acquisition single-shot turbo spin echo imaging -- MRCP magnetic resonance cholangiopancreatography -- SENSE sensitivity encoding -- SPACE sampling perfection with application-optimized contrast -- SS-FSE single-shot fast spin echo -- TSE turbo spin echo
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2021.109873 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18887.xml