Clinical feasibility study of 3D intracranial magnetic resonance angiography using compressed sensing. Issue 6 (13th April 2019)
- Record Type:
- Journal Article
- Title:
- Clinical feasibility study of 3D intracranial magnetic resonance angiography using compressed sensing. Issue 6 (13th April 2019)
- Main Title:
- Clinical feasibility study of 3D intracranial magnetic resonance angiography using compressed sensing
- Authors:
- Lin, Zhiyong
Zhang, Xiaodong
Guo, Li
Wang, Ke
Jiang, Yuan
Hu, Xiaoyu
Huang, Yong
Wei, Juan
Ma, Shuai
Liu, Yi
Zhu, Lina
Zhuo, Zhizheng
Liu, Jing
Wang, Xiaoying - Abstract:
- Abstract : Background: Compressed sensing (CS) has been widely used to improve the speed of MRI, but the feasibility of application in 3D intracranial MR angiography (MRA) needs to be evaluated in clinical practice. Purpose: To evaluate the clinical feasibility of CS‐MRA in comparison with conventional 3D‐MRA (Con‐MRA). Study Type: Retrospective. Subjects: Forty‐nine consecutive patients with suspected intracranial arterial disease. Field Strength/Sequence: 3T MRI. 3D time‐of‐flight (TOF) MRA using a CS algorithm and conventional 3D TOF MRA scan. Assessment: Three radiologists (4, 11, and 12 years of experience in neuroradiology) independently assessed the image quality, vascular lesions, and variations of intracranial arteries of both CS‐MRA and Con‐MRA, respectively. Statistical Tests: The Kendall W test was performed to assess the interobserver agreement of image quality and intracranial arterial stenosis. A nonparametric test (Wilcoxon test) was used for comparison of the image quality and definition of the external carotid artery (ECA). Weighted kappa analysis was performed for the interstudy agreement of intracranial arterial stenosis. The aneurysm, decreased branches, congenital hypoplasia, absence, and variant branching of intracranial arteries were observed and evaluated for interobserver agreement and interstudy agreement by kappa analysis. Paired‐ t ‐tests for signal‐to‐noise ratio (SNR) and contrast‐to‐noise ratio (CNR) were conducted. Results: Image quality isAbstract : Background: Compressed sensing (CS) has been widely used to improve the speed of MRI, but the feasibility of application in 3D intracranial MR angiography (MRA) needs to be evaluated in clinical practice. Purpose: To evaluate the clinical feasibility of CS‐MRA in comparison with conventional 3D‐MRA (Con‐MRA). Study Type: Retrospective. Subjects: Forty‐nine consecutive patients with suspected intracranial arterial disease. Field Strength/Sequence: 3T MRI. 3D time‐of‐flight (TOF) MRA using a CS algorithm and conventional 3D TOF MRA scan. Assessment: Three radiologists (4, 11, and 12 years of experience in neuroradiology) independently assessed the image quality, vascular lesions, and variations of intracranial arteries of both CS‐MRA and Con‐MRA, respectively. Statistical Tests: The Kendall W test was performed to assess the interobserver agreement of image quality and intracranial arterial stenosis. A nonparametric test (Wilcoxon test) was used for comparison of the image quality and definition of the external carotid artery (ECA). Weighted kappa analysis was performed for the interstudy agreement of intracranial arterial stenosis. The aneurysm, decreased branches, congenital hypoplasia, absence, and variant branching of intracranial arteries were observed and evaluated for interobserver agreement and interstudy agreement by kappa analysis. Paired‐ t ‐tests for signal‐to‐noise ratio (SNR) and contrast‐to‐noise ratio (CNR) were conducted. Results: Image quality is better for CS‐MRA compared with Con‐MRA with significance (Z = –3.710 to –2.673, with P < 0.01). The interstudy agreement of lesion and variation of intracranial arteries assessment for each observer was excellent. The SNR and CNR were significantly higher in CS‐MRA compared with Con‐MRA ( P < 0.001). The definition of ECA of CS‐MRA was significantly better (Z = –4.9, P < 0.001). Data Conclusion: CS‐MRA showed significantly higher image quality with less blur, comparable image diagnostic performance of intracranial arteries, and better display of ECA than Con‐MRA. Level of Evidence : 3 Technical Efficacy Stage : 2 J. Magn. Reson. Imaging 2019;50:1843–1851. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 50:Issue 6(2019)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 50:Issue 6(2019)
- Issue Display:
- Volume 50, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 50
- Issue:
- 6
- Issue Sort Value:
- 2019-0050-0006-0000
- Page Start:
- 1843
- Page End:
- 1851
- Publication Date:
- 2019-04-13
- Subjects:
- magnetic resonance angiography -- compressed sensing algorithm -- cerebrovascular disease
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.26752 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18810.xml