Anatomic and volumetric characterization of the cisterna chyli using CT lymphangiography and computer‐assisted design software in dogs with idiopathic chylothorax. Issue 3 (3rd March 2020)
- Record Type:
- Journal Article
- Title:
- Anatomic and volumetric characterization of the cisterna chyli using CT lymphangiography and computer‐assisted design software in dogs with idiopathic chylothorax. Issue 3 (3rd March 2020)
- Main Title:
- Anatomic and volumetric characterization of the cisterna chyli using CT lymphangiography and computer‐assisted design software in dogs with idiopathic chylothorax
- Authors:
- Carvajal, Jose L.
Case, J. Brad
Vilaplana Grosso, Federico
Huynh, Elizabeth
Verpaalen, Valentine
Fox‐Alvarez, Alexander
Regier, Penny J. - Abstract:
- Abstract: The objectives of this retrospective, observational study were to characterize the anatomical features of the cisterna chyli (CC) in a cohort of dogs diagnosed with idiopathic chylothorax that underwent CT lymphangiography (CTLa), and to evaluate the feasibility of computer‐assisted design (CAD) software to quantify volumetric measurements of the CC. Twenty‐three client‐owned dogs with idiopathic chylothorax were included. Additionally, CTLa was performed in three canine cadavers to assess the ability of CAD software to accurately acquire volumetric measurements. Injection sites, attenuation values, anatomic location, dimensions, and aortic diameter to CC ratio (Ao:CC) were recorded. Video records of video‐assisted thoracic surgery (VATS) thoracic duct ligation (TDL) were reviewed in eight out of 23 dogs to compare operative and CTLa findings. The CC was dorsal and right‐sided in 18 out of 23 dogs, located between L1 and L4 in 21 dogs, and extended as far cranially as T11 in two dogs. The median measurements for length, height, and width were 150.0, 5.5, and 13.3 mm, respectively. Median total volume was 1.82 mL. Median volumes to the right and left of the aorta were 1.46 and 0.49 mL, respectively ( P = .014). Median total CC volume to body weight ratio (CC:bw) was 0.07 mL/kg. The presence of an intrathoracic CC was observed intraoperatively in six out of eight cases that underwent VATS TDL. Findings supported the use of CTLa and CAD as feasible methods forAbstract: The objectives of this retrospective, observational study were to characterize the anatomical features of the cisterna chyli (CC) in a cohort of dogs diagnosed with idiopathic chylothorax that underwent CT lymphangiography (CTLa), and to evaluate the feasibility of computer‐assisted design (CAD) software to quantify volumetric measurements of the CC. Twenty‐three client‐owned dogs with idiopathic chylothorax were included. Additionally, CTLa was performed in three canine cadavers to assess the ability of CAD software to accurately acquire volumetric measurements. Injection sites, attenuation values, anatomic location, dimensions, and aortic diameter to CC ratio (Ao:CC) were recorded. Video records of video‐assisted thoracic surgery (VATS) thoracic duct ligation (TDL) were reviewed in eight out of 23 dogs to compare operative and CTLa findings. The CC was dorsal and right‐sided in 18 out of 23 dogs, located between L1 and L4 in 21 dogs, and extended as far cranially as T11 in two dogs. The median measurements for length, height, and width were 150.0, 5.5, and 13.3 mm, respectively. Median total volume was 1.82 mL. Median volumes to the right and left of the aorta were 1.46 and 0.49 mL, respectively ( P = .014). Median total CC volume to body weight ratio (CC:bw) was 0.07 mL/kg. The presence of an intrathoracic CC was observed intraoperatively in six out of eight cases that underwent VATS TDL. Findings supported the use of CTLa and CAD as feasible methods for characterizing the CC in dogs diagnosed with chylothorax. These methods may facilitate interventional planning involving the CC such as embolization. … (more)
- Is Part Of:
- Veterinary radiology & ultrasound. Volume 61:Issue 3(2020)
- Journal:
- Veterinary radiology & ultrasound
- Issue:
- Volume 61:Issue 3(2020)
- Issue Display:
- Volume 61, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 61
- Issue:
- 3
- Issue Sort Value:
- 2020-0061-0003-0000
- Page Start:
- 312
- Page End:
- 321
- Publication Date:
- 2020-03-03
- Subjects:
- chylothorax -- computer‐assisted design -- CT lymphangiography -- idiopathic chylothorax
Veterinary radiology -- Periodicals
Radiologie vétérinaire -- Périodiques
Échographie vétérinaire -- Périodiques
Radiography -- Periodicals
Ultrasonography -- Periodicals
Diagnosis -- Periodicals
Veterinary Medicine -- Periodicals
Societies, Medical -- Periodicals
636.089607 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1740-8261 ↗
http://www.blackwell-synergy.com/loi/vru ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1058-8183;screen=info;ECOIP ↗
http://www.blackwell-synergy.com/loi/vru ↗ - DOI:
- 10.1111/vru.12851 ↗
- Languages:
- English
- ISSNs:
- 1058-8183
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9229.281000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18805.xml