Intraoperative Use of O-arm in Pediatric Cervical Spine Surgery. Issue 4 (April 2020)
- Record Type:
- Journal Article
- Title:
- Intraoperative Use of O-arm in Pediatric Cervical Spine Surgery. Issue 4 (April 2020)
- Main Title:
- Intraoperative Use of O-arm in Pediatric Cervical Spine Surgery
- Authors:
- Verhofste, Bram P.
Glotzbecker, Michael P.
Hresko, Michael T.
MacDougall, Robert D.
Birch, Craig M.
O'Neill, Nora P.
Karlin, Lawrence I.
Emans, John B.
Proctor, Mark R.
Hedequist, Daniel J. - Abstract:
- Abstract : Introduction: Traditionally, fluoroscopy and postoperative computed tomographic (CT) scans are used to evaluate screw position after pediatric cervical spine fusion. However, noncontained screws detected postoperatively can require revision surgery. Intraoperative O-arm is a 3-dimensional CT imaging technique, which allows intraoperative evaluation of screw position and potentially avoids reoperations because of implant malposition. This study's objective was to evaluate the use of intraoperative O-arm in determining the accuracy of cervical implants placed by a free-hand technique using anatomic landmarks or fluoroscopic guidance in pediatric cervical spine instrumentation. Methods: A single-center retrospective study of consecutive examinations of children treated with cervical spine instrumentation and intraoperative O-arm from 2014 to 2018 was performed. In total, 44 cases (41 children, 44% men) with a mean age of 11.9 years (range, 2.1 to 23.5 y) were identified. Instability (n=16, 36%) and deformity (n=10, 23%) were the most frequent indications. Primary outcomes were screw revision rate, neurovascular complications caused by noncontained screws, and radiation exposure. Results: A total of 272 screws were inserted (60 occipital and 212 cervical screws). All screws were evaluated on fluoroscopy as appropriately placed. Four screws (1.5%) in 4 cases (9%) were noncontained on O-arm imaging and required intraoperative revision. A mean of 7.7 levels (range, 5 toAbstract : Introduction: Traditionally, fluoroscopy and postoperative computed tomographic (CT) scans are used to evaluate screw position after pediatric cervical spine fusion. However, noncontained screws detected postoperatively can require revision surgery. Intraoperative O-arm is a 3-dimensional CT imaging technique, which allows intraoperative evaluation of screw position and potentially avoids reoperations because of implant malposition. This study's objective was to evaluate the use of intraoperative O-arm in determining the accuracy of cervical implants placed by a free-hand technique using anatomic landmarks or fluoroscopic guidance in pediatric cervical spine instrumentation. Methods: A single-center retrospective study of consecutive examinations of children treated with cervical spine instrumentation and intraoperative O-arm from 2014 to 2018 was performed. In total, 44 cases (41 children, 44% men) with a mean age of 11.9 years (range, 2.1 to 23.5 y) were identified. Instability (n=16, 36%) and deformity (n=10, 23%) were the most frequent indications. Primary outcomes were screw revision rate, neurovascular complications caused by noncontained screws, and radiation exposure. Results: A total of 272 screws were inserted (60 occipital and 212 cervical screws). All screws were evaluated on fluoroscopy as appropriately placed. Four screws (1.5%) in 4 cases (9%) were noncontained on O-arm imaging and required intraoperative revision. A mean of 7.7 levels (range, 5 to 13) were scanned. The mean CT dose index and dose-length product were 15.2±6.87 mGy and 212.3±120.48 mGy×cm. Mean effective dose was 1.57±0.818 mSv. There was no association between screw location and noncontainment ( P =0.129). No vertebral artery injuries, dural injuries, or neurologic deficits were related to the 4 revised screws. Conclusions: Intraoperative non-navigated O-arm is a safe and efficient method to evaluate screw position in pediatric patients undergoing cervical spine instrumentation. Noncontained screws were detected in 9% of cases (n=4). O-arm delivers low radiation doses, allows for intraoperative screw revision, and negates the need for postoperative CT scans after confirmation of optimal implant position. Level of Evidence: Level IV. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Journal of pediatric orthopaedics. Volume 40:Issue 4(2020)
- Journal:
- Journal of pediatric orthopaedics
- Issue:
- Volume 40:Issue 4(2020)
- Issue Display:
- Volume 40, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 40
- Issue:
- 4
- Issue Sort Value:
- 2020-0040-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-04
- Subjects:
- pediatric -- cervical spine -- spinal fusion -- intraoperative CT -- radiation
Pediatric orthopedics -- Periodicals
618.927 - Journal URLs:
- http://journals.lww.com/pedorthopaedics/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=01241398-000000000-00000 ↗
http://www.pedorthopaedics.com/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/BPO.0000000000001416 ↗
- Languages:
- English
- ISSNs:
- 0271-6798
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5030.225000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18788.xml