Central aortic blood pressure estimation in children and adolescents: results of the KidCoreBP study. Issue 5 (May 2020)
- Record Type:
- Journal Article
- Title:
- Central aortic blood pressure estimation in children and adolescents: results of the KidCoreBP study. Issue 5 (May 2020)
- Main Title:
- Central aortic blood pressure estimation in children and adolescents
- Authors:
- Mynard, Jonathan P.
Goldsmith, Greta
Springall, Gabriella
Eastaugh, Lucas
Lane, Geoffrey K.
Zannino, Diana
Smolich, Joseph J.
Avolio, Alberto
Cheung, Michael M.H. - Abstract:
- Abstract : Background: Central aortic SBP (cSBP) may have superior prognostic value compared with peripheral SBP (pSBP), but noninvasive cSBP measurement techniques have not been formally validated in children and adolescents. Method: This study assessed the accuracy of two automated devices and the radial tonometry/transfer function method (RT-TF) for estimating central pressures and pulse pressure amplification (PPA) in this population, with adherence to validation guidelines for central pressure devices. In 69 children/adolescents aged 3–18 years undergoing clinically indicated aortic catheterization, high fidelity ascending aortic cSBP was measured with a micromanometer-tipped wire and compared with values from SphygmoCor XCEL, Mobil-O-Graph (systolic/diastolic calibration, MoG-C1, or mean/diastolic calibration, MoG-C2) and RT-TF. Reference intra-arterial pSBP was derived from the tonometry pulse calibrated to central mean/diastolic pressures. Results: XCEL, MoG-C1 and MoG-C2 overestimated cSBP by 7.9 ± 6.8 mmHg (mean ± SD), 5.7 ± 10.3 mmHg, and 19.1 ± 14.9 mmHg, exceeding the validation cut-off (5 ± 8 mmHg). Brachial pSBP was also overestimated by XCEL (10.9 ± 8.4 mmHg) and Mobil-O-Graph (11.5 ± 12.3 mmHg). By contrast, central and brachial diastolic pressures were underestimated by the automated devices, albeit mostly within acceptable limits; pulse pressures were, therefore, substantially overestimated. Central-brachial PPA (4.5 ± 4.4 mmHg) was overestimated by XCELAbstract : Background: Central aortic SBP (cSBP) may have superior prognostic value compared with peripheral SBP (pSBP), but noninvasive cSBP measurement techniques have not been formally validated in children and adolescents. Method: This study assessed the accuracy of two automated devices and the radial tonometry/transfer function method (RT-TF) for estimating central pressures and pulse pressure amplification (PPA) in this population, with adherence to validation guidelines for central pressure devices. In 69 children/adolescents aged 3–18 years undergoing clinically indicated aortic catheterization, high fidelity ascending aortic cSBP was measured with a micromanometer-tipped wire and compared with values from SphygmoCor XCEL, Mobil-O-Graph (systolic/diastolic calibration, MoG-C1, or mean/diastolic calibration, MoG-C2) and RT-TF. Reference intra-arterial pSBP was derived from the tonometry pulse calibrated to central mean/diastolic pressures. Results: XCEL, MoG-C1 and MoG-C2 overestimated cSBP by 7.9 ± 6.8 mmHg (mean ± SD), 5.7 ± 10.3 mmHg, and 19.1 ± 14.9 mmHg, exceeding the validation cut-off (5 ± 8 mmHg). Brachial pSBP was also overestimated by XCEL (10.9 ± 8.4 mmHg) and Mobil-O-Graph (11.5 ± 12.3 mmHg). By contrast, central and brachial diastolic pressures were underestimated by the automated devices, albeit mostly within acceptable limits; pulse pressures were, therefore, substantially overestimated. Central-brachial PPA (4.5 ± 4.4 mmHg) was overestimated by XCEL (8.7 ± 3.2 mmHg) and MoG-C1 (11.1 ± 6.4 mmHg), but underestimated by MoG-C2 (−3.0 ± 6.6 mmHg). Given accurate pulse calibration, RT-TF achieved acceptable accuracy for cSBP (−0.2 ± 4.6 mmHg) and central-radial PPA (1.9 ± 5.1 mmHg). Conclusion: In conclusion, XCEL and Mobil-O-Graph overestimated pSBP and cSBP in children and adolescents. cSBP can be obtained via the same transfer function used in adults, but accurate pressure pulse calibration is critical. Video Abstracts: http://links.lww.com/HJH/B222 Abstract : Supplemental Digital Content is available in the text … (more)
- Is Part Of:
- Journal of hypertension. Volume 38:Issue 5(2020:May)
- Journal:
- Journal of hypertension
- Issue:
- Volume 38:Issue 5(2020:May)
- Issue Display:
- Volume 38, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 38
- Issue:
- 5
- Issue Sort Value:
- 2020-0038-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-05
- Subjects:
- aorta -- central blood pressure -- children -- device -- hypertension -- validation
Hypertension -- Periodicals
Hypertension -- Periodicals
616.132005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://journals.lww.com/jhypertension/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00004872-000000000-00000 ↗
http://www.jhypertension.com/ ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/HJH.0000000000002338 ↗
- Languages:
- English
- ISSNs:
- 1473-5598
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5004.510000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18794.xml