Precision in Oculofacial Surgery: Made-To-Specification Cast-Molded Implants in Orbital Reconstruction. Issue 3 (May 2020)
- Record Type:
- Journal Article
- Title:
- Precision in Oculofacial Surgery: Made-To-Specification Cast-Molded Implants in Orbital Reconstruction. Issue 3 (May 2020)
- Main Title:
- Precision in Oculofacial Surgery
- Authors:
- Chen, Allison J.
Chung, Natalie N.
Liu, Catherine Y.
MacIntosh, Peter W.
Korn, Bobby S.
Kikkawa, Don O. - Abstract:
- Abstract : Purpose: To describe the utilization of customized made-to-specification porous polyethylene implants and to evaluate clinical characteristics and outcomes of patients who received these implants for unilateral orbital defects. Methods: A retrospective review of 9 patients was performed. Three-dimensional surface models were generated from high-resolution computed tomography scans. Orbital constructs were modeled after the normal, contralateral orbits and mirrored across the vertical midline to generate the target orbital implant. Measured outcomes included globe position, extraocular motility, facial symmetry, and diplopia. Results: Patients ranged 25–56 years old (mean: 37) and included 6 males and 3 females. Cases consisted of 6 orbital floor fractures due to trauma, 1 lateral wall defect after neurofibroma resection, 1 floor/medial wall defect after myxoma resection, and 1 superior orbital rim defect after intraosseous hemangioma resection. Seven patients had ≥1 prior repair. All patients had previous hard and soft tissue defects and varying degrees of restrictive globe motility. Patients exhibited improved ductions after implant placement and improved facial appearance and symmetry. Post-operatively, 1 patient was found to have a small orbital hematoma between the implant and orbital floor, resolving within weeks. Conclusions: Precision, personalized oculofacial surgery is the next wave in tailoring surgical care to the individual patient. CustomizableAbstract : Purpose: To describe the utilization of customized made-to-specification porous polyethylene implants and to evaluate clinical characteristics and outcomes of patients who received these implants for unilateral orbital defects. Methods: A retrospective review of 9 patients was performed. Three-dimensional surface models were generated from high-resolution computed tomography scans. Orbital constructs were modeled after the normal, contralateral orbits and mirrored across the vertical midline to generate the target orbital implant. Measured outcomes included globe position, extraocular motility, facial symmetry, and diplopia. Results: Patients ranged 25–56 years old (mean: 37) and included 6 males and 3 females. Cases consisted of 6 orbital floor fractures due to trauma, 1 lateral wall defect after neurofibroma resection, 1 floor/medial wall defect after myxoma resection, and 1 superior orbital rim defect after intraosseous hemangioma resection. Seven patients had ≥1 prior repair. All patients had previous hard and soft tissue defects and varying degrees of restrictive globe motility. Patients exhibited improved ductions after implant placement and improved facial appearance and symmetry. Post-operatively, 1 patient was found to have a small orbital hematoma between the implant and orbital floor, resolving within weeks. Conclusions: Precision, personalized oculofacial surgery is the next wave in tailoring surgical care to the individual patient. Customizable implants are manufactured to specifically mold to an individual patient's unique bony architecture, which can lead to superior outcomes in reconstructing orbital and craniofacial bony defects. This technique is particularly useful in patients with prior unsuccessful repair. Abstract : We describe the utilization and outcomes of customized made-to-specification porous polyethylene implants in patients with complex orbital defects. … (more)
- Is Part Of:
- Ophthalmic plastic and reconstructive surgery. Volume 36:Issue 3(2020)
- Journal:
- Ophthalmic plastic and reconstructive surgery
- Issue:
- Volume 36:Issue 3(2020)
- Issue Display:
- Volume 36, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 36
- Issue:
- 3
- Issue Sort Value:
- 2020-0036-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-05
- Subjects:
- Eye -- Surgery -- Periodicals
Ophthalmic plastic surgery -- Periodicals
Reconstructive Surgical Procedures -- Periodicals
Ophthalmologic Surgical Procedures -- Periodicals
Ophthalmology -- Periodicals
Surgery -- Periodicals
617.70592 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00002341-000000000-00000 ↗
http://www.op-rs.com ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/IOP.0000000000001529 ↗
- Languages:
- English
- ISSNs:
- 0740-9303
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6271.430000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18789.xml