- A cohort-based comprehensive characterization of different patterns of very short-term, within-visit, blood pressure variability
- Authors:
- Papaioannou, Theodore G.
Protogerou, Athanase D.
Stamatelopoulos, Kimon S.
Alexandraki, Krystallenia I.
Vrachatis, Dimitrios
Argyris, Antonios
Papaioannou, Vasilios
Vavuranakis, Manolis
Stefanadis, Christodoulos
Tousoulis, Dimitrios - Abstract:
- Abstract : Aim: To characterize different patterns of variability of three repeated within-visit blood pressure (BP) readings and to determine the prevalence of specific variation trends in systolic (SBP), diastolic (DBP) blood pressure and pulse pressure (PP). Methods: Data from 53 737 subjects from the National Health and Nutrition Examination Survey were analyzed. In each subject, three consecutive BP measurements were performed with a minimum time-interval of at least 30 s. We propose three patterns of within-visit BP variability (separately for SBP, DBP and PP): (1) increasing trend (BP3 > BP2 > BP1 ); (2) decreasing trend (BP1 > BP2 > BP3 ) and (3) no trend (BP3 ≈ BP2 ≈ BP1 ). A threshold of minimum change (ΔP > 3 mmHg) between BP1 -BP2 and BP2 -BP3 was also applied as a prerequisite for the definition of these trends. Results: An increasing trend was observed among three consecutive measurements of SBP, DBP and PP in 7.4, 10.4 and 10.2%, respectively. When a minimum threshold of 3 mmHg was set the respective increasing trends were observed in 1.8, 2.9 and 4.4%, respectively. There was a higher prevalence of decreasing trend within three consecutive SBP, DBP and PP readings: 17, 13.1 and 16.2%, respectively, whereas using a threshold of ΔP >3 mmHg the respective prevalence was 6.3, 4.1 and 7.7%. A maximum absolute difference >10 mmHg within triplicate of SBP/DBP/PP readings was observed in 12.9, 13 and 29.4%, respectively. In the era of personalized medicine,Abstract : Aim: To characterize different patterns of variability of three repeated within-visit blood pressure (BP) readings and to determine the prevalence of specific variation trends in systolic (SBP), diastolic (DBP) blood pressure and pulse pressure (PP). Methods: Data from 53 737 subjects from the National Health and Nutrition Examination Survey were analyzed. In each subject, three consecutive BP measurements were performed with a minimum time-interval of at least 30 s. We propose three patterns of within-visit BP variability (separately for SBP, DBP and PP): (1) increasing trend (BP3 > BP2 > BP1 ); (2) decreasing trend (BP1 > BP2 > BP3 ) and (3) no trend (BP3 ≈ BP2 ≈ BP1 ). A threshold of minimum change (ΔP > 3 mmHg) between BP1 -BP2 and BP2 -BP3 was also applied as a prerequisite for the definition of these trends. Results: An increasing trend was observed among three consecutive measurements of SBP, DBP and PP in 7.4, 10.4 and 10.2%, respectively. When a minimum threshold of 3 mmHg was set the respective increasing trends were observed in 1.8, 2.9 and 4.4%, respectively. There was a higher prevalence of decreasing trend within three consecutive SBP, DBP and PP readings: 17, 13.1 and 16.2%, respectively, whereas using a threshold of ΔP >3 mmHg the respective prevalence was 6.3, 4.1 and 7.7%. A maximum absolute difference >10 mmHg within triplicate of SBP/DBP/PP readings was observed in 12.9, 13 and 29.4%, respectively. In the era of personalized medicine, these patterns are well worth further investigation concerning their pathophysiologic and clinical relevance. … (more)
- Is Part Of:
- Blood pressure monitoring. Volume 25:Issue 3(2020)
- Journal:
- Blood pressure monitoring
- Issue:
- Volume 25:Issue 3(2020)
- Issue Display:
- Volume 25, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 25
- Issue:
- 3
- Issue Sort Value:
- 2020-0025-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-06
- Subjects:
- arterial pressure -- hemodynamics -- sphygmomanometer
Blood pressure -- Measurement -- Periodicals
Blood Pressure Determination -- Periodicals
Blood Pressure Monitoring, Ambulatory -- Periodicals
Blood Pressure Monitors -- Periodicals
Hypertension -- Periodicals
612.140287 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00126097-000000000-00000&NEWS=N ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00126097-000000000-00000 ↗
http://www.bpmonitoring.com/ ↗
http://journals.lww.com/pages/default.aspx ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1097/MBP.0000000000000435 ↗
- Languages:
- English
- ISSNs:
- 1359-5237
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2113.035500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18778.xml