Comparison of Locked Plating of Varus Displaced Proximal Humeral Fractures With and Without Fibula Allograft Augmentation. Issue 4 (April 2020)
- Record Type:
- Journal Article
- Title:
- Comparison of Locked Plating of Varus Displaced Proximal Humeral Fractures With and Without Fibula Allograft Augmentation. Issue 4 (April 2020)
- Main Title:
- Comparison of Locked Plating of Varus Displaced Proximal Humeral Fractures With and Without Fibula Allograft Augmentation
- Authors:
- Davids, Stephen
Allen, Dexter
Desarno, Michael
Endres, Nathan K.
Bartlett, Craig
Shafritz, Adam - Abstract:
- Abstract : Objective: To compare the clinical and radiographic outcomes between patients treated with fibula allograft-augmented locking compression fixation and patients treated with locking compression fixation alone for 2- and 3-part proximal humeral fractures with varus displacement. Design: Retrospective review. Setting: Level 1 trauma center. Patients/Participants: One hundred two patients treated with locking plate fixation ± fibular allograft augmentation confirmed intraoperatively by visual inspection to have varus-angulated, 2- and 3-part proximal humerus fractures with at least 45 degrees of varus angulation at the neck/shaft and at least 1 cm of displacement. Intervention: Proximal humerus locking plate (PHILOS; Synthes, Paoli, PA) with or without fibula allograft augmentation. Main Outcome Measurements: Statistical analysis to determine the differences between fractures treated with locking compression fixation ± fibula allograft augmentation regarding complications, shoulder reported outcome measures, and patient ROMs (Visual Analog Score (VAS), Disabilities of the Arm, Shoulder and Hand, and Simple Shoulder Test scores). Medical comorbidities as potential risk factors for complication from surgery were also evaluated. Results: Of 102 surgical cases, 27 were augmented with fibula allograft and 75 were not. Postoperatively, there were 16 noncatastrophic varus collapses of the fracture, 6 catastrophic varus collapses, and 5 deaths. Addition of fibula allograftAbstract : Objective: To compare the clinical and radiographic outcomes between patients treated with fibula allograft-augmented locking compression fixation and patients treated with locking compression fixation alone for 2- and 3-part proximal humeral fractures with varus displacement. Design: Retrospective review. Setting: Level 1 trauma center. Patients/Participants: One hundred two patients treated with locking plate fixation ± fibular allograft augmentation confirmed intraoperatively by visual inspection to have varus-angulated, 2- and 3-part proximal humerus fractures with at least 45 degrees of varus angulation at the neck/shaft and at least 1 cm of displacement. Intervention: Proximal humerus locking plate (PHILOS; Synthes, Paoli, PA) with or without fibula allograft augmentation. Main Outcome Measurements: Statistical analysis to determine the differences between fractures treated with locking compression fixation ± fibula allograft augmentation regarding complications, shoulder reported outcome measures, and patient ROMs (Visual Analog Score (VAS), Disabilities of the Arm, Shoulder and Hand, and Simple Shoulder Test scores). Medical comorbidities as potential risk factors for complication from surgery were also evaluated. Results: Of 102 surgical cases, 27 were augmented with fibula allograft and 75 were not. Postoperatively, there were 16 noncatastrophic varus collapses of the fracture, 6 catastrophic varus collapses, and 5 deaths. Addition of fibula allograft did not significantly affect postoperative varus collapse, shoulder ROM, pain, or PROMs. Conclusion: Addition of fibula allograft to patients sustaining varus-angulated, 2- and 3-part proximal humeral fractures conferred no benefit to patient outcomes at our institution. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence. Abstract : Supplemental Digital Content is Available in the Text. … (more)
- Is Part Of:
- Journal of orthopaedic trauma. Volume 34:Issue 4(2020)
- Journal:
- Journal of orthopaedic trauma
- Issue:
- Volume 34:Issue 4(2020)
- Issue Display:
- Volume 34, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 34
- Issue:
- 4
- Issue Sort Value:
- 2020-0034-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-04
- Subjects:
- proximal humerus fracture -- locking plate -- fibula allograft -- varus malalignment
Orthopedics -- Periodicals
Wounds and injuries -- Periodicals
Orthopedics -- Periodicals
Wounds and Injuries -- therapy -- Periodicals
Periodicals
617.47044 - Journal URLs:
- http://journals.lww.com/jorthotrauma/pages/default.aspx ↗
http://www.jorthotrauma.com ↗
http://cufts2.lib.sfu.ca/CJDB/BVAS/journal/149202 ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00005131-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/BOT.0000000000001679 ↗
- Languages:
- English
- ISSNs:
- 0890-5339
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5027.675000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18786.xml