The influence of SBP amplification on the accuracy of form-factor-derived mean arterial pressure. Issue 6 (June 2020)
- Record Type:
- Journal Article
- Title:
- The influence of SBP amplification on the accuracy of form-factor-derived mean arterial pressure. Issue 6 (June 2020)
- Main Title:
- The influence of SBP amplification on the accuracy of form-factor-derived mean arterial pressure
- Authors:
- Schultz, Martin G.
Picone, Dean S.
Armstrong, Mathew K.
Black, J. Andrew
Dwyer, Nathan
Roberts-Thomson, Philip
Sturgess, David
Sharman, James E. - Abstract:
- Abstract : Objectives: Accurate assessment of mean arterial pressure (MAP) is crucial in research and clinical settings. Measurement of MAP requires not only pressure waveform integration but can also be estimated via form-factor equations incorporating peripheral SBP. SBP may increase variably from central-to-peripheral arteries (SBP amplification), and could influence accuracy of form-factor-derived MAP, which we aimed to determine. Methods: One hundred and eighty-eight patients (69% men, age 60 ± 10 years) undergoing coronary angiography had intra-arterial pressure measured in the ascending aorta, brachial and radial arteries. Reference MAP was measured by waveform integration, and form-factor-derived MAP using 33 and 40% form-factors. Results: Reference MAP decreased from the aorta to the brachial (−0.7 ± 4.2 mmHg) and radial artery (−1.7 ± 4.8 mmHg), whereas form-factor-derived MAP increased (33% form-factor 1.1 ± 4.2 and 1.7 ± 4.7 mmHg; 40% form-factor 0.9 ± 4.8 and 1.4 ± 5.4 mmHg, respectively). Form-factor-derived MAP was significantly different to reference aortic MAP (33% form-factor −2.5 ± 4.6 and −1.6 ± 5.8, P < 0.001; 40% form-factor 2.5 ± 5.0 and 3.9 ± 6.4 mmHg, P < 0.001, brachial and radial arteries, respectively), with significant variation in the brachial form-factor required (FFreq ) to generate MAP equivalent to reference aortic MAP (FFreq range 20–57% brachial; 17–74% radial). Aortic-to-brachial SBP amplification was strongly related to brachial FFreqAbstract : Objectives: Accurate assessment of mean arterial pressure (MAP) is crucial in research and clinical settings. Measurement of MAP requires not only pressure waveform integration but can also be estimated via form-factor equations incorporating peripheral SBP. SBP may increase variably from central-to-peripheral arteries (SBP amplification), and could influence accuracy of form-factor-derived MAP, which we aimed to determine. Methods: One hundred and eighty-eight patients (69% men, age 60 ± 10 years) undergoing coronary angiography had intra-arterial pressure measured in the ascending aorta, brachial and radial arteries. Reference MAP was measured by waveform integration, and form-factor-derived MAP using 33 and 40% form-factors. Results: Reference MAP decreased from the aorta to the brachial (−0.7 ± 4.2 mmHg) and radial artery (−1.7 ± 4.8 mmHg), whereas form-factor-derived MAP increased (33% form-factor 1.1 ± 4.2 and 1.7 ± 4.7 mmHg; 40% form-factor 0.9 ± 4.8 and 1.4 ± 5.4 mmHg, respectively). Form-factor-derived MAP was significantly different to reference aortic MAP (33% form-factor −2.5 ± 4.6 and −1.6 ± 5.8, P < 0.001; 40% form-factor 2.5 ± 5.0 and 3.9 ± 6.4 mmHg, P < 0.001, brachial and radial arteries, respectively), with significant variation in the brachial form-factor required (FFreq ) to generate MAP equivalent to reference aortic MAP (FFreq range 20–57% brachial; 17–74% radial). Aortic-to-brachial SBP amplification was strongly related to brachial FFreq ( r = −0.695, P < 0.001). The 33% form-factor was most accurate with high aortic-to-brachial SBP amplification (33% form-factor MAP vs. reference aortic MAP difference 0.06 ± 3.93 mmHg, P = 0.89) but overestimated reference aortic MAP with low aortic-to-brachial SBP amplification (+5.8 ± 4.6 mmHg, P < 0.001). The opposite was observed for the 40% form-factor. Conclusion: Due to variable SBP amplification, estimating MAP via form-factors produces nonphysiological inaccurate values. These findings have important implications for accurate assessment of MAP in research and clinical settings. … (more)
- Is Part Of:
- Journal of hypertension. Volume 38:Issue 6(2020:Jun.)
- Journal:
- Journal of hypertension
- Issue:
- Volume 38:Issue 6(2020:Jun.)
- Issue Display:
- Volume 38, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 38
- Issue:
- 6
- Issue Sort Value:
- 2020-0038-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-06
- Subjects:
- amplification -- artery -- blood pressure -- haemodynamic monitoring -- homeostasis
Hypertension -- Periodicals
Hypertension -- Periodicals
616.132005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://journals.lww.com/jhypertension/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00004872-000000000-00000 ↗
http://www.jhypertension.com/ ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/HJH.0000000000002385 ↗
- Languages:
- English
- ISSNs:
- 1473-5598
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5004.510000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18793.xml