Flushing Versus Pushing Technique for Graft Implantation in Descemet Membrane Endothelial Keratoplasty. Issue 5 (May 2020)
- Record Type:
- Journal Article
- Title:
- Flushing Versus Pushing Technique for Graft Implantation in Descemet Membrane Endothelial Keratoplasty. Issue 5 (May 2020)
- Main Title:
- Flushing Versus Pushing Technique for Graft Implantation in Descemet Membrane Endothelial Keratoplasty
- Authors:
- Siebelmann, Sebastian
Janetzko, Mona
König, Peter
Scholz, Paula
Matthaei, Mario
Händel, Alexander
Cursiefen, Claus
Bachmann, Björn - Abstract:
- Abstract : Purpose: Descemet membrane endothelial keratoplasty (DMEK) has developed into a safe procedure for the replacement of diseased corneal endothelium. However, DMEK still results in a significant donor endothelial cell loss. Here, we compare 2 different graft implantation techniques. Methods: Twenty patients undergoing DMEK, where a DMEK injection cartridge was used to flush the graft into the anterior chamber (G-38635 single-use DMEK-Cartridge; Geuder AG, Heidelberg, Germany; group A), were retrospectively compared with 20 patients, where a standard lens injection cartridge (AT.Smart Cartridge; Carl Zeiss Meditec AG, Jena, Germany; group B) was used to push the graft with a plunger. Outcome parameters were intraoperative orientation of the graft, insertion-to-attachment time, rebubbling rates, and postoperative best spectacle-corrected visual acuity, endothelial cell count, and central corneal thickness after 12 months. The surfaces of both cartridges were evaluated by scanning electron microscopy. Results: In group A, the insertion-to-attachment time was significantly higher ( P = 0.003). Initially, the graft was oriented correctly in 40% of the patients in group A compared with 90% in group B ( P = 0.001). No differences were obtained between both groups regarding central corneal thickness, endothelial cell count or best spectacle-corrected visual acuity, and rebubbling rates after 12 months. Scanning electron microscopy analysis demonstrated a rougher and sharperAbstract : Purpose: Descemet membrane endothelial keratoplasty (DMEK) has developed into a safe procedure for the replacement of diseased corneal endothelium. However, DMEK still results in a significant donor endothelial cell loss. Here, we compare 2 different graft implantation techniques. Methods: Twenty patients undergoing DMEK, where a DMEK injection cartridge was used to flush the graft into the anterior chamber (G-38635 single-use DMEK-Cartridge; Geuder AG, Heidelberg, Germany; group A), were retrospectively compared with 20 patients, where a standard lens injection cartridge (AT.Smart Cartridge; Carl Zeiss Meditec AG, Jena, Germany; group B) was used to push the graft with a plunger. Outcome parameters were intraoperative orientation of the graft, insertion-to-attachment time, rebubbling rates, and postoperative best spectacle-corrected visual acuity, endothelial cell count, and central corneal thickness after 12 months. The surfaces of both cartridges were evaluated by scanning electron microscopy. Results: In group A, the insertion-to-attachment time was significantly higher ( P = 0.003). Initially, the graft was oriented correctly in 40% of the patients in group A compared with 90% in group B ( P = 0.001). No differences were obtained between both groups regarding central corneal thickness, endothelial cell count or best spectacle-corrected visual acuity, and rebubbling rates after 12 months. Scanning electron microscopy analysis demonstrated a rougher and sharper surface of the shooter of group B. Conclusions: This study shows significant differences between both insertion techniques regarding correct graft orientation directly after graft implantation leading to prolonged insertion-to-attachment time when the graft is flushed instead of pushed into the anterior chamber. … (more)
- Is Part Of:
- Cornea. Volume 39:Issue 5(2020)
- Journal:
- Cornea
- Issue:
- Volume 39:Issue 5(2020)
- Issue Display:
- Volume 39, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 39
- Issue:
- 5
- Issue Sort Value:
- 2020-0039-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-05
- Subjects:
- DMEK -- shooter -- injection device -- graft insertion
Cornea -- Periodicals
Cornea -- Periodicals
Cornée -- Périodiques
617.719 - Journal URLs:
- http://journals.lww.com/corneajrnl/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICO.0000000000002239 ↗
- Languages:
- English
- ISSNs:
- 0277-3740
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3470.927500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18778.xml