A Combined Biomechanical and Tomographic Model for Identifying Cases of Subclinical Keratoconus. Issue 4 (April 2020)
- Record Type:
- Journal Article
- Title:
- A Combined Biomechanical and Tomographic Model for Identifying Cases of Subclinical Keratoconus. Issue 4 (April 2020)
- Main Title:
- A Combined Biomechanical and Tomographic Model for Identifying Cases of Subclinical Keratoconus
- Authors:
- Atalay, Eray
Özalp, Onur
Erol, Mehmet Akif
Bilgin, Muzaffer
Yıldırım, Nilgün - Abstract:
- Abstract : Purpose: To develop a combined biomechanical and tomographic model for identifying eyes with subclinical keratoconus (SKC) that are categorized as normal or borderline in the Pentacam Belin/Ambrósio Enhanced Ectasia Display. Methods: This case–control study comprised 62 eyes with SKC and randomly selected eyes of 186 age-matched healthy controls. SKC was defined as the presence of the following: 1) normal topography, topometric indices, and slit lamp; 2) normal or borderline Belin/Ambrósio Enhanced Ectasia Display D index, back and front elevation difference; and 3) keratoconus in the fellow eye. Stepwise logistic regression analysis was performed to identify the best variable combination for detecting SKC cases from Ocular Response Analyzer and Pentacam parameters. Receiver operating characteristic curve analysis was used to determine the predictive accuracy [area under the curve (AUC)] of the model. Based on the predictors in the final logistic regression model, a linear equation was derived using the discriminant function analysis. Results: The final model (AUC: 0.948, sensitivity: 87.1%, and specificity: 91.4%) chose corneal hysteresis (CH) and D index from a total of 63 candidate variables. The final model had a higher AUC compared with D (0.933, P = 0.053) and CH (0.80, P < 0.001) alone. According to the discriminant function analysis, a higher CH was required with increasing D index to classify an eye as normal. Conclusions: The proposed combined modelAbstract : Purpose: To develop a combined biomechanical and tomographic model for identifying eyes with subclinical keratoconus (SKC) that are categorized as normal or borderline in the Pentacam Belin/Ambrósio Enhanced Ectasia Display. Methods: This case–control study comprised 62 eyes with SKC and randomly selected eyes of 186 age-matched healthy controls. SKC was defined as the presence of the following: 1) normal topography, topometric indices, and slit lamp; 2) normal or borderline Belin/Ambrósio Enhanced Ectasia Display D index, back and front elevation difference; and 3) keratoconus in the fellow eye. Stepwise logistic regression analysis was performed to identify the best variable combination for detecting SKC cases from Ocular Response Analyzer and Pentacam parameters. Receiver operating characteristic curve analysis was used to determine the predictive accuracy [area under the curve (AUC)] of the model. Based on the predictors in the final logistic regression model, a linear equation was derived using the discriminant function analysis. Results: The final model (AUC: 0.948, sensitivity: 87.1%, and specificity: 91.4%) chose corneal hysteresis (CH) and D index from a total of 63 candidate variables. The final model had a higher AUC compared with D (0.933, P = 0.053) and CH (0.80, P < 0.001) alone. According to the discriminant function analysis, a higher CH was required with increasing D index to classify an eye as normal. Conclusions: The proposed combined model provided varying cutoffs for CH and D as a function of the other. The probability plot as a function of CH and D index may be used for identifying eyes with SKC. Abstract : Supplemental Digital Content is Available in the Text. … (more)
- Is Part Of:
- Cornea. Volume 39:Issue 4(2020)
- Journal:
- Cornea
- Issue:
- Volume 39:Issue 4(2020)
- Issue Display:
- Volume 39, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 39
- Issue:
- 4
- Issue Sort Value:
- 2020-0039-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-04
- Subjects:
- keratoconus -- subclinical keratoconus -- corneal biomechanics -- tomography -- pentacam -- ocular response analyzer
Cornea -- Periodicals
Cornea -- Periodicals
Cornée -- Périodiques
617.719 - Journal URLs:
- http://journals.lww.com/corneajrnl/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICO.0000000000002205 ↗
- Languages:
- English
- ISSNs:
- 0277-3740
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3470.927500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18791.xml