Application of a standardized EEG pattern classification in the assessment of neurological prognosis after cardiac arrest: A retrospective analysis. (August 2021)
- Record Type:
- Journal Article
- Title:
- Application of a standardized EEG pattern classification in the assessment of neurological prognosis after cardiac arrest: A retrospective analysis. (August 2021)
- Main Title:
- Application of a standardized EEG pattern classification in the assessment of neurological prognosis after cardiac arrest: A retrospective analysis
- Authors:
- Lilja, Linus
Joelsson, Sara
Nilsson, Josefin
Lindgren, Sophie
Rylander, Christian - Abstract:
- Abstract: Introduction: Electroencephalogram (EEG) is used in the neurological prognostication after cardiac arrest. "Highly malignant" EEG patterns classified according to Westhall have a high specificity for poor neurological outcome when applied within protocols of recent studies. However, their predictive performance when applied in everyday clinical practice has not been investigated. We studied the prognostic accuracy and the interrater agreement when standardized EEG patterns were analysed and compared to neurological outcome in a patient cohort at a tertiary centre not involved in the original study of the standardized EEG pattern classification. Methods: Comatose patients treated for out-of-hospital cardiac arrest were included. Poor outcome was defined as Cerebral Performance Category 3–5. Two senior consultants and one resident in clinical neurophysiology, blinded to clinical data and outcome, independently reviewed their EEG registrations and categorised the pattern as "highly malignant", "malignant" or "benign". These categories were compared to neurological outcome at hospital discharge. Interrater agreement was assessed using Cohen's Kappa. Results: In total, 62 patients were included. The median (IQR) time to EEG was 59 (42–91) h after return of spontaneous circulation. Poor outcome was found in 52 (84%) patients. In 21 patients at least one of the raters considered the EEG to contain a "highly malignant" pattern, all with poor outcome (42% sensitivity, 100%Abstract: Introduction: Electroencephalogram (EEG) is used in the neurological prognostication after cardiac arrest. "Highly malignant" EEG patterns classified according to Westhall have a high specificity for poor neurological outcome when applied within protocols of recent studies. However, their predictive performance when applied in everyday clinical practice has not been investigated. We studied the prognostic accuracy and the interrater agreement when standardized EEG patterns were analysed and compared to neurological outcome in a patient cohort at a tertiary centre not involved in the original study of the standardized EEG pattern classification. Methods: Comatose patients treated for out-of-hospital cardiac arrest were included. Poor outcome was defined as Cerebral Performance Category 3–5. Two senior consultants and one resident in clinical neurophysiology, blinded to clinical data and outcome, independently reviewed their EEG registrations and categorised the pattern as "highly malignant", "malignant" or "benign". These categories were compared to neurological outcome at hospital discharge. Interrater agreement was assessed using Cohen's Kappa. Results: In total, 62 patients were included. The median (IQR) time to EEG was 59 (42–91) h after return of spontaneous circulation. Poor outcome was found in 52 (84%) patients. In 21 patients at least one of the raters considered the EEG to contain a "highly malignant" pattern, all with poor outcome (42% sensitivity, 100% specificity). The interrater agreement varied from kappa 0.62 to 0.29. Conclusion: "Highly malignant" patterns predict poor neurological outcome with a high specificity in everyday practice. However, interrater agreement may vary substantially even between experienced EEG interpreters. … (more)
- Is Part Of:
- Resuscitation. Volume 165(2021)
- Journal:
- Resuscitation
- Issue:
- Volume 165(2021)
- Issue Display:
- Volume 165, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 165
- Issue:
- 2021
- Issue Sort Value:
- 2021-0165-2021-0000
- Page Start:
- 38
- Page End:
- 44
- Publication Date:
- 2021-08
- Subjects:
- EEG pattern -- Comatose -- Cardiac arrest -- Neurological prognosis
Resuscitation -- Periodicals
Resuscitation -- Periodicals
Réanimation -- Périodiques
Electronic journals
616.025 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03009572 ↗
http://www.resuscitationjournal.com/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03009572 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/03009572 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.resuscitation.2021.05.037 ↗
- Languages:
- English
- ISSNs:
- 0300-9572
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7785.420000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18776.xml