Understanding the uptake of new hip replacement implants in the UK: a cohort study using data from the National Joint Registry for England and Wales. Issue 11 (25th November 2019)
- Record Type:
- Journal Article
- Title:
- Understanding the uptake of new hip replacement implants in the UK: a cohort study using data from the National Joint Registry for England and Wales. Issue 11 (25th November 2019)
- Main Title:
- Understanding the uptake of new hip replacement implants in the UK: a cohort study using data from the National Joint Registry for England and Wales
- Authors:
- Penfold, Chris M
Blom, Ashley W
Sayers, Adrian
Wilkinson, J Mark
Hunt, Linda
Judge, Andrew
Whitehouse, Michael R - Abstract:
- Abstract : Objectives: Primary: describe uptake of new implant components (femoral stem or acetabular cup/shell) for total hip replacements (THRs) in the National Joint Registry for England and Wales (NJR). Secondary: compare the characteristics of: (a) surgeons and (b) patients who used/received new rather than established components. Design: Cohort of 618 393 primary THRs performed for osteoarthritis (±other indications) by 4979 surgeons between 2008 and 2017 in England and Wales from the NJR. We described the uptake of new (first recorded use >2008, used within 5 years) stems/cups, and variation in uptake by surgeons (primary objectives). We explored surgeon-level and patient-level factors associated with use/receipt of new components with logistic regression models (secondary objectives). Outcomes: Primary outcomes: total number of new cups/stems, proportion of operations using new versus established components. Secondary outcomes: odds of: (a) a surgeon using a new cup/stem in a calendar-year, (b) a patient receiving a new rather than established cup/stem. Results: Sixty-eight new cups and 72 new stems were used in 47 606 primary THRs (7.7%) by 2005 surgeons (40.3%) 2008–2017. Surgeons used a median of one new stem and cup (25%–75%=1–2 both, max=10 cups, max=8 stems). Surgeons performed a median total of 22 THRs (25%–75%=5–124, range=1–3938) in the period 2008–2017. Surgeons used new stems in a median of 5.0% (25%–75%=1.3%–16.1%) and new cups in a median of 9.4%Abstract : Objectives: Primary: describe uptake of new implant components (femoral stem or acetabular cup/shell) for total hip replacements (THRs) in the National Joint Registry for England and Wales (NJR). Secondary: compare the characteristics of: (a) surgeons and (b) patients who used/received new rather than established components. Design: Cohort of 618 393 primary THRs performed for osteoarthritis (±other indications) by 4979 surgeons between 2008 and 2017 in England and Wales from the NJR. We described the uptake of new (first recorded use >2008, used within 5 years) stems/cups, and variation in uptake by surgeons (primary objectives). We explored surgeon-level and patient-level factors associated with use/receipt of new components with logistic regression models (secondary objectives). Outcomes: Primary outcomes: total number of new cups/stems, proportion of operations using new versus established components. Secondary outcomes: odds of: (a) a surgeon using a new cup/stem in a calendar-year, (b) a patient receiving a new rather than established cup/stem. Results: Sixty-eight new cups and 72 new stems were used in 47 606 primary THRs (7.7%) by 2005 surgeons (40.3%) 2008–2017. Surgeons used a median of one new stem and cup (25%–75%=1–2 both, max=10 cups, max=8 stems). Surgeons performed a median total of 22 THRs (25%–75%=5–124, range=1–3938) in the period 2008–2017. Surgeons used new stems in a median of 5.0% (25%–75%=1.3%–16.1%) and new cups in a median of 9.4% (25%–75%=2.8%–26.7%) of their THRs. Patients aged <55 years old versus those 55–80 had higher odds of receiving a new rather than established stem (OR=1.83, 95% CI=1.73–1.93) and cup (OR=1.31, 95% CI=1.25–1.37). Women had lower odds of receiving a new stem (OR=0.87, 95% CI=0.84–0.90), higher odds of receiving a new cup (OR=1.06, 95% CI=1.03–1.09). Conclusions: Large numbers of new THR components have been introduced in the NJR since 2008. 40% of surgeons have tried new components, with wide variation in how many types and frequency they have been used. … (more)
- Is Part Of:
- BMJ open. Volume 9:Issue 11(2019)
- Journal:
- BMJ open
- Issue:
- Volume 9:Issue 11(2019)
- Issue Display:
- Volume 9, Issue 11 (2019)
- Year:
- 2019
- Volume:
- 9
- Issue:
- 11
- Issue Sort Value:
- 2019-0009-0011-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-11-25
- Subjects:
- orthopaedics -- joint replacement -- implant -- patient -- surgeon -- national joint registry
Medicine -- Research -- Periodicals
610.72 - Journal URLs:
- http://www.bmj.com/archive ↗
http://bmjopen.bmj.com/ ↗ - DOI:
- 10.1136/bmjopen-2019-029572 ↗
- Languages:
- English
- ISSNs:
- 2044-6055
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18756.xml