The practical application of reflectance spectrophotometry for the demonstration of haemoglobin and its degradation in bruises. Issue 4 (26th March 2004)
- Record Type:
- Journal Article
- Title:
- The practical application of reflectance spectrophotometry for the demonstration of haemoglobin and its degradation in bruises. Issue 4 (26th March 2004)
- Main Title:
- The practical application of reflectance spectrophotometry for the demonstration of haemoglobin and its degradation in bruises
- Authors:
- Hughes, V K
Ellis, P S
Burt, T
Langlois, N E I - Abstract:
- Abstract : Aims: To develop a non-invasive method to demonstrate the presence of haemoglobin and its degradation products in bruises in live human subjects for the purposes of objectively assisting in the determination of the age of a bruise. Methods: The cuvette holder unit of a Cary 100 Bio UV-Visible Spectrophotometer was replaced with the manufacture's fibre optic cable and optical reflectance probe. The probe was placed on the skin surface. The absorption spectrum from 780 to 380 nm was collected and transformed into the first derivative. Calculation of the first derivative permits absorption attributed to haemoglobin degradation (primarily to bilirubin, but also haemosiderin) to be separated from absorption by haemoglobin. First derivative and colorimetry values, expressed as CIEL*a*b data, were derived from scans of 50 bruises. Results: The fibre optic cable and probe allowed the spectrophotometer to collect reproducible absorption spectra of bruises in the skin of living subjects. A bruise at three days has greater negative first derivative values at 480 and 490 nm than does a fresh bruise, indicating the local degradation of haemoglobin. Correlation between the first derivative and the CIEL*a*b "b" values in a series of bruises indicates that the yellow colour in a bruise is proportional to the amount of local haemoglobin breakdown. Conclusion: The ability to demonstrate the presence of haemoglobin and measure its degradation in bruises in living human subjects by aAbstract : Aims: To develop a non-invasive method to demonstrate the presence of haemoglobin and its degradation products in bruises in live human subjects for the purposes of objectively assisting in the determination of the age of a bruise. Methods: The cuvette holder unit of a Cary 100 Bio UV-Visible Spectrophotometer was replaced with the manufacture's fibre optic cable and optical reflectance probe. The probe was placed on the skin surface. The absorption spectrum from 780 to 380 nm was collected and transformed into the first derivative. Calculation of the first derivative permits absorption attributed to haemoglobin degradation (primarily to bilirubin, but also haemosiderin) to be separated from absorption by haemoglobin. First derivative and colorimetry values, expressed as CIEL*a*b data, were derived from scans of 50 bruises. Results: The fibre optic cable and probe allowed the spectrophotometer to collect reproducible absorption spectra of bruises in the skin of living subjects. A bruise at three days has greater negative first derivative values at 480 and 490 nm than does a fresh bruise, indicating the local degradation of haemoglobin. Correlation between the first derivative and the CIEL*a*b "b" values in a series of bruises indicates that the yellow colour in a bruise is proportional to the amount of local haemoglobin breakdown. Conclusion: The ability to demonstrate the presence of haemoglobin and measure its degradation in bruises in living human subjects by a non-invasive method has not been described previously, and may be of use in the objective ageing of bruises for forensic purposes. … (more)
- Is Part Of:
- Journal of clinical pathology. Volume 57:Issue 4(2004)
- Journal:
- Journal of clinical pathology
- Issue:
- Volume 57:Issue 4(2004)
- Issue Display:
- Volume 57, Issue 4 (2004)
- Year:
- 2004
- Volume:
- 57
- Issue:
- 4
- Issue Sort Value:
- 2004-0057-0004-0000
- Page Start:
- 355
- Page End:
- 359
- Publication Date:
- 2004-03-26
- Subjects:
- forensic science -- spectrophotometry -- contusion -- bilirubin -- biliverdin -- haemosiderin -- haemoglobin -- time factors -- colorimetry
CIE, Commission Internationale de l'Eclairage
Pathology -- Periodicals
Pathology, Molecular -- Periodicals
616.0705 - Journal URLs:
- http://jcp.bmjjournals.com ↗
http://jcp.bmjjournals.com/content/by/year ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=162&action=archive ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/jcp.2003.011445 ↗
- Languages:
- English
- ISSNs:
- 0021-9746
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18759.xml