Variability in echocardiography and MRI for detection of cancer therapy cardiotoxicity. Issue 11 (25th February 2020)
- Record Type:
- Journal Article
- Title:
- Variability in echocardiography and MRI for detection of cancer therapy cardiotoxicity. Issue 11 (25th February 2020)
- Main Title:
- Variability in echocardiography and MRI for detection of cancer therapy cardiotoxicity
- Authors:
- Lambert, James
Lamacie, Mariana
Thampinathan, Babitha
Altaha, Mustafa A
Esmaeilzadeh, Maryam
Nolan, Mark
Fresno, Camila Urzua
Somerset, Emily
Amir, Eitan
Marwick, Thomas H
Wintersperger, Bernd J
Thavendiranathan, Paaladinesh - Abstract:
- Abstract : Objectives: To compare variability of echocardiographic and cardiovascular magnetic resonance (CMR) measured left ventricular (LV) function parameters and their relationship to cancer therapeutics-related cardiac dysfunction (CTRCD). Methods: We prospectively recruited 60 participants (age: 49.8±11.6 years), 30 women with human epidermal growth factor receptor 2-positive breast cancer (15 with CTRCD and 15 without CTRCD) and 30 healthy volunteers. Patients were treated with anthracyclines and trastuzumab. Participants underwent three serial CMR (1.5T) and echocardiography studies at ~3-month intervals. Cine-CMR for LV ejection fraction (LVEF), myocardial tagging for global longitudinal strain (GLS) and global circumferential strain (GCS), two-dimensional (2D) echocardiography for strain and LVEF and three-dimensional (3D) echocardiography for LVEF measurements were obtained. Temporal, interobserver and intraobserver variability were calculated as the coefficient of variation and as the SE of the measurement (SEM). Minimal detected difference (MDD) was defined as 2xSEM. Results: Patients with CTRCD demonstrated larger mean temporal changes in all parameters compared with those without: 2D-LVEF: 4.6% versus 2.8%; 3D-LVEF: 5.2% vs 2.3%; CMR-LVEF: 6.6% versus 2.7%; 2D-GLS: 1.9% versus 0.7%, 2D-GCS: 2.5% versus 2.2%; CMR-GCS: 2.7% versus 1.6%; and CMR-GLS: 2.1% versus 1.4%, with overlap in 95% CI for 2D-LVEF, 2D-GCS, CMR-GLS and CMR-GCS. The respective mean temporalAbstract : Objectives: To compare variability of echocardiographic and cardiovascular magnetic resonance (CMR) measured left ventricular (LV) function parameters and their relationship to cancer therapeutics-related cardiac dysfunction (CTRCD). Methods: We prospectively recruited 60 participants (age: 49.8±11.6 years), 30 women with human epidermal growth factor receptor 2-positive breast cancer (15 with CTRCD and 15 without CTRCD) and 30 healthy volunteers. Patients were treated with anthracyclines and trastuzumab. Participants underwent three serial CMR (1.5T) and echocardiography studies at ~3-month intervals. Cine-CMR for LV ejection fraction (LVEF), myocardial tagging for global longitudinal strain (GLS) and global circumferential strain (GCS), two-dimensional (2D) echocardiography for strain and LVEF and three-dimensional (3D) echocardiography for LVEF measurements were obtained. Temporal, interobserver and intraobserver variability were calculated as the coefficient of variation and as the SE of the measurement (SEM). Minimal detected difference (MDD) was defined as 2xSEM. Results: Patients with CTRCD demonstrated larger mean temporal changes in all parameters compared with those without: 2D-LVEF: 4.6% versus 2.8%; 3D-LVEF: 5.2% vs 2.3%; CMR-LVEF: 6.6% versus 2.7%; 2D-GLS: 1.9% versus 0.7%, 2D-GCS: 2.5% versus 2.2%; CMR-GCS: 2.7% versus 1.6%; and CMR-GLS: 2.1% versus 1.4%, with overlap in 95% CI for 2D-LVEF, 2D-GCS, CMR-GLS and CMR-GCS. The respective mean temporal variability/MDD in healthy volunteers were 3.3%/6.5%, 1.8%/3.7%, 2.2%/4.4%, 0.8%/1.5%, 1.9%/3.7%, 1.8%/3.6% and 1.4%/2.8%. Although the mean temporal variability in healthy volunteers was lower than the mean temporal changes in CTRCD, at the individual level, 2D-GLS, 3D-LVEF and CMR-LVEF had the least overlap. 2D-GLS and CMR-LVEF had the lowest interobserver/intraobserver variabilities. Conclusion: Temporal changes in 3D-LVEF, 2D-GLS and CMR LVEF in patients with CTRCD had the least overlap with the variability in healthy volunteers; however, 2D-GLS appears to be the most suitable for clinical application in individual patients. … (more)
- Is Part Of:
- Heart. Volume 106:Issue 11(2020)
- Journal:
- Heart
- Issue:
- Volume 106:Issue 11(2020)
- Issue Display:
- Volume 106, Issue 11 (2020)
- Year:
- 2020
- Volume:
- 106
- Issue:
- 11
- Issue Sort Value:
- 2020-0106-0011-0000
- Page Start:
- 817
- Page End:
- 823
- Publication Date:
- 2020-02-25
- Subjects:
- cardiac imaging and diagnostics -- echocardiography -- cardiac magnetic resonance (CMR) imaging
Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/heartjnl-2019-316297 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18752.xml