Evaluating Propofol Concentration in Blood From Exhaled Gas Using a Breathing-Related Partition Coefficient. (April 2020)
- Record Type:
- Journal Article
- Title:
- Evaluating Propofol Concentration in Blood From Exhaled Gas Using a Breathing-Related Partition Coefficient. (April 2020)
- Main Title:
- Evaluating Propofol Concentration in Blood From Exhaled Gas Using a Breathing-Related Partition Coefficient
- Authors:
- Dong, Hao
Zhang, Fengjiang
Chen, Jing
Yu, Qiwen
Zhong, Yinbo
Liu, Jun
Yan, Min
Chen, Xing - Abstract:
- Abstract : BACKGROUND: The anesthetic side effects of propofol still occur in clinical practice because no reliable monitoring techniques are available. In this regard, continuous monitoring of propofol in breath is a promising method, yet it remains infeasible because there is large variation in the blood/exhaled gas partial pressure ratio (RBE ) in humans. Further evaluations of the influences of breathing-related factors on RBE would mitigate this variation. METHODS: Correlations were analyzed between breathing-related factors (tidal volume [TV], breath frequency [BF], and minute ventilation [VM ]) and RBE in 46 patients. Furthermore, a subset of 10 patients underwent pulmonary function tests (PFTs), and the parameters of the PFTs were then compared with the RBE . We employed a 1-phase exponential decay model to characterize the influence of VM on RBE . We also proposed a modified RBE (RBEM ) that was not affected by the different breathing patterns of the patients. The blood concentration of propofol was predicted from breath monitoring using RBEM and RBE . RESULTS: We found a significant negative correlation ( R = −0.572; P < .001) between VM and RBE (N = 46). No significant correlation was shown between PFTs and RBE in the subset (N = 10). RBEM demonstrated a standard Gaussian distribution (mean, 1.000; standard deviation [SD], 0.308). Moreover, the predicted propofol concentrations based on breath monitoring matched well with the measured blood concentrations. The 90%Abstract : BACKGROUND: The anesthetic side effects of propofol still occur in clinical practice because no reliable monitoring techniques are available. In this regard, continuous monitoring of propofol in breath is a promising method, yet it remains infeasible because there is large variation in the blood/exhaled gas partial pressure ratio (RBE ) in humans. Further evaluations of the influences of breathing-related factors on RBE would mitigate this variation. METHODS: Correlations were analyzed between breathing-related factors (tidal volume [TV], breath frequency [BF], and minute ventilation [VM ]) and RBE in 46 patients. Furthermore, a subset of 10 patients underwent pulmonary function tests (PFTs), and the parameters of the PFTs were then compared with the RBE . We employed a 1-phase exponential decay model to characterize the influence of VM on RBE . We also proposed a modified RBE (RBEM ) that was not affected by the different breathing patterns of the patients. The blood concentration of propofol was predicted from breath monitoring using RBEM and RBE . RESULTS: We found a significant negative correlation ( R = −0.572; P < .001) between VM and RBE (N = 46). No significant correlation was shown between PFTs and RBE in the subset (N = 10). RBEM demonstrated a standard Gaussian distribution (mean, 1.000; standard deviation [SD], 0.308). Moreover, the predicted propofol concentrations based on breath monitoring matched well with the measured blood concentrations. The 90% prediction band was limited to within ±1 μg·mL −1 . CONCLUSIONS: The prediction of propofol concentration in blood was more accurate using RBEM than when using RBE and could provide reference information for anesthesiologists. Moreover, the present study provided a general approach for assessing the influence of relevant physiological factors and will inform noninvasive and accurate breath assessment of volatile drugs or metabolites in blood. … (more)
- Is Part Of:
- Anesthesia & analgesia. Volume 130:Number 4(2020)
- Journal:
- Anesthesia & analgesia
- Issue:
- Volume 130:Number 4(2020)
- Issue Display:
- Volume 130, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 130
- Issue:
- 4
- Issue Sort Value:
- 2020-0130-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-04
- Subjects:
- Anesthesiology -- Periodicals
Anesthesia
Anesthesiology
Analgesia
Analgesics
Anesthesiology -- Periodicals
617.9605 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00000539-000000000-00000 ↗
http://journals.lww.com/anesthesia-analgesia/Pages/default.aspx ↗
http://www.anesthesia-analgesia.org ↗
http://journals.lww.com ↗ - DOI:
- 10.1213/ANE.0000000000004225 ↗
- Languages:
- English
- ISSNs:
- 0003-2999
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0900.500000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18731.xml