Usefulness of Prestorage Corneal Swab Culture in the Prevention of Contaminated Corneal Tissue in Corneal Transplantation. Issue 7 (July 2020)
- Record Type:
- Journal Article
- Title:
- Usefulness of Prestorage Corneal Swab Culture in the Prevention of Contaminated Corneal Tissue in Corneal Transplantation. Issue 7 (July 2020)
- Main Title:
- Usefulness of Prestorage Corneal Swab Culture in the Prevention of Contaminated Corneal Tissue in Corneal Transplantation
- Authors:
- Szigiato, Andrei-Alexandru
Anderson, Maude
Mabon, Michèle
Germain, Marc
Durr, Georges M.
Labbé, Annie-Claude - Abstract:
- Abstract : Purpose: To assess the efficacy of the prestorage corneal swab (PCS) culture to screen for corneal graft contamination after storage in Optisol-GS. Methods: A retrospective analysis of all PCS cultures was performed at the Eye Bank of Québec in Hôpital Maisonneuve-Rosemont from September 2013 to June 2016. Whole corneal culture was performed on rejected grafts because of a positive PCS, and a contamination rate was calculated. In addition, contamination rates of corneoscleral rims were compared between corneas tested with PCS and those of imported corneas which did not have PCS. Results: Among the 1966 PCS cultures performed, 814 (41.4%) were positive for growth. Pathogenic bacteria were present in 144 (7.3%) corneas, including Staphylococcus aureus (n = 96, 11.8% of all positive cultures), Enterobacteriaceae (n = 14, 1.7%), and Pseudomonas aeruginosa (n = 6, 0.7%). After preservation in Optisol-GS, only 7 (6.9%) corneas remained contaminated (95% confidence interval 5.1–9.3). The sensitivity of the PCS culture was 87.5% (95% confidence interval 47.4–99.7). There was no significant difference in corneoscleral rim contamination between corneas tested with PCS (1/388; 0.2%) compared with imported, nonswabbed corneas (3/214; 1.4%) ( P = 0.131). Therefore, the cost to recover the loss of tissue rejected because of false-positive PCS by purchasing corneal tissue was calculated to be $142, 884 (CAD) per year. Conclusions: Despite the high sensitivity of PCS cultures,Abstract : Purpose: To assess the efficacy of the prestorage corneal swab (PCS) culture to screen for corneal graft contamination after storage in Optisol-GS. Methods: A retrospective analysis of all PCS cultures was performed at the Eye Bank of Québec in Hôpital Maisonneuve-Rosemont from September 2013 to June 2016. Whole corneal culture was performed on rejected grafts because of a positive PCS, and a contamination rate was calculated. In addition, contamination rates of corneoscleral rims were compared between corneas tested with PCS and those of imported corneas which did not have PCS. Results: Among the 1966 PCS cultures performed, 814 (41.4%) were positive for growth. Pathogenic bacteria were present in 144 (7.3%) corneas, including Staphylococcus aureus (n = 96, 11.8% of all positive cultures), Enterobacteriaceae (n = 14, 1.7%), and Pseudomonas aeruginosa (n = 6, 0.7%). After preservation in Optisol-GS, only 7 (6.9%) corneas remained contaminated (95% confidence interval 5.1–9.3). The sensitivity of the PCS culture was 87.5% (95% confidence interval 47.4–99.7). There was no significant difference in corneoscleral rim contamination between corneas tested with PCS (1/388; 0.2%) compared with imported, nonswabbed corneas (3/214; 1.4%) ( P = 0.131). Therefore, the cost to recover the loss of tissue rejected because of false-positive PCS by purchasing corneal tissue was calculated to be $142, 884 (CAD) per year. Conclusions: Despite the high sensitivity of PCS cultures, there was no significant reduction of infection after corneal transplantation using this technique. In consequence, 93% of the corneas possibly suitable for transplantation were rejected. This suggests that the PCS culture alone is a poor test for detecting clinically relevant corneal contamination. … (more)
- Is Part Of:
- Cornea. Volume 39:Issue 7(2020)
- Journal:
- Cornea
- Issue:
- Volume 39:Issue 7(2020)
- Issue Display:
- Volume 39, Issue 7 (2020)
- Year:
- 2020
- Volume:
- 39
- Issue:
- 7
- Issue Sort Value:
- 2020-0039-0007-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-07
- Subjects:
- corneal transplantation -- infection -- conjunctival swab -- corneal swab -- sensitivity -- corneal culture
Cornea -- Periodicals
Cornea -- Periodicals
Cornée -- Périodiques
617.719 - Journal URLs:
- http://journals.lww.com/corneajrnl/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICO.0000000000002267 ↗
- Languages:
- English
- ISSNs:
- 0277-3740
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3470.927500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18726.xml