Evaluation of the C-MAC Miller Video Laryngoscope Sizes 0 and 1 During Tracheal Intubation of Infants Less Than 10 kg. Issue 7 (July 2020)
- Record Type:
- Journal Article
- Title:
- Evaluation of the C-MAC Miller Video Laryngoscope Sizes 0 and 1 During Tracheal Intubation of Infants Less Than 10 kg. Issue 7 (July 2020)
- Main Title:
- Evaluation of the C-MAC Miller Video Laryngoscope Sizes 0 and 1 During Tracheal Intubation of Infants Less Than 10 kg
- Authors:
- Raimann, Florian J.
Cuca, Colleen E.
Kern, Detlev
Zacharowski, Kai
Rolle, Udo
Meininger, Dirk
Weber, Christian F.
Byhahn, Christian
Mutlak, Haitham - Abstract:
- Abstract : Study Objective: Video laryngoscopy has primarily been developed to assist in difficult airways. Using video laryngoscopy in pediatric airway management is an up-and-coming topic. The aim of the presented study was to compare the intubation conditions obtained when using the C-MAC video laryngoscope with Miller blades sizes 0 and 1 for standard direct laryngoscopy and indirect laryngoscopy in children weighing less than 10 kg. Design: This was a prospective study. Setting: The study was performed in a university hospital. Patients: Following ethical approval, 86 infants weighing less than 10 kg and undergoing surgery under general anesthesia were studied prospectively. Intervention: Indirect and direct laryngoscopy either with C-MAC Miller blade size 0 or size 1. Measurements: First, direct laryngoscopy was performed, and the best obtained view was graded without looking at the video monitor. A second investigator blinded to the view obtained under direct laryngoscopy graded the laryngeal view on the video monitor. Time to intubation, intubation conditions, and intubation attempts were recorded. Results: In infants less than 10 kg, intubation conditions were excellent. There were no significant differences between the use of Miller blade 0 or 1 in reference to Cormack-Lehane grade, time to intubation, time to best view, or intubation attempts. Comparing direct and indirect intubation conditions using either Miller blade 0 or 1 revealed that the use of indirectAbstract : Study Objective: Video laryngoscopy has primarily been developed to assist in difficult airways. Using video laryngoscopy in pediatric airway management is an up-and-coming topic. The aim of the presented study was to compare the intubation conditions obtained when using the C-MAC video laryngoscope with Miller blades sizes 0 and 1 for standard direct laryngoscopy and indirect laryngoscopy in children weighing less than 10 kg. Design: This was a prospective study. Setting: The study was performed in a university hospital. Patients: Following ethical approval, 86 infants weighing less than 10 kg and undergoing surgery under general anesthesia were studied prospectively. Intervention: Indirect and direct laryngoscopy either with C-MAC Miller blade size 0 or size 1. Measurements: First, direct laryngoscopy was performed, and the best obtained view was graded without looking at the video monitor. A second investigator blinded to the view obtained under direct laryngoscopy graded the laryngeal view on the video monitor. Time to intubation, intubation conditions, and intubation attempts were recorded. Results: In infants less than 10 kg, intubation conditions were excellent. There were no significant differences between the use of Miller blade 0 or 1 in reference to Cormack-Lehane grade, time to intubation, time to best view, or intubation attempts. Comparing direct and indirect intubation conditions using either Miller blade 0 or 1 revealed that the use of indirect laryngoscopy provided a significantly better view ( P < 0.05) of the vocal cords. In 3 infants weighing more than 8 kg, the Miller blade 0 was described as too short and narrow for intubation. Conclusions: Both devices allowed for an excellent visualization of the vocal cords. … (more)
- Is Part Of:
- Pediatric emergency care. Volume 36:Issue 7(2020)
- Journal:
- Pediatric emergency care
- Issue:
- Volume 36:Issue 7(2020)
- Issue Display:
- Volume 36, Issue 7 (2020)
- Year:
- 2020
- Volume:
- 36
- Issue:
- 7
- Issue Sort Value:
- 2020-0036-0007-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-07
- Subjects:
- airway management -- endotracheal intubation -- laryngoscopy, infant
Pediatric emergencies -- Periodicals
618.92002505 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00006565-000000000-00000 ↗
http://www.pec-online.com ↗
http://journals.lww.com/pec-online/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/PEC.0000000000001296 ↗
- Languages:
- English
- ISSNs:
- 0749-5161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6417.586000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18728.xml