Respiratory Motion Detection and Correction for MR Using the Pilot Tone: Applications for MR and Simultaneous PET/MR Examinations. Issue 3 (March 2020)
- Record Type:
- Journal Article
- Title:
- Respiratory Motion Detection and Correction for MR Using the Pilot Tone: Applications for MR and Simultaneous PET/MR Examinations. Issue 3 (March 2020)
- Main Title:
- Respiratory Motion Detection and Correction for MR Using the Pilot Tone
- Authors:
- Vahle, Thomas
Bacher, Mario
Rigie, David
Fenchel, Matthias
Speier, Peter
Bollenbeck, Jan
Schäfers, Klaus P.
Kiefer, Berthold
Boada, Fernando E. - Abstract:
- Abstract : Objectives: The aim of this study was to develop a method for tracking respiratory motion throughout full MR or PET/MR studies that requires only minimal additional hardware and no modifications to the sequences. Materials and Methods: Patient motion that is caused by respiration affects the quality of the signal of the individual radiofrequency receive coil elements. This effect can be detected as a modulation of a monofrequent signal that is emitted by a small portable transmitter placed inside the bore (Pilot Tone). The frequency is selected such that it is located outside of the frequency band of the actual MR readout experiment but well within the bandwidth of the radiofrequency receiver, that is, the oversampling area. Temporal variations of the detected signal indicate motion. After extraction of the signal from the raw data, principal component analysis was used to identify respiratory motion. The approach and potential applications during MR and PET/MR examinations that rely on a continuous respiratory signal were validated with an anthropomorphic, PET/MR-compatible motion phantom as well as in a volunteer study. Results: Respiratory motion detection and correction were presented for MR and PET data in phantom and volunteer studies. The Pilot Tone successfully recovered the ground-truth respiratory signal provided by the phantom. Conclusions: The presented method provides reliable respiratory motion tracking during arbitrary imaging sequences throughout aAbstract : Objectives: The aim of this study was to develop a method for tracking respiratory motion throughout full MR or PET/MR studies that requires only minimal additional hardware and no modifications to the sequences. Materials and Methods: Patient motion that is caused by respiration affects the quality of the signal of the individual radiofrequency receive coil elements. This effect can be detected as a modulation of a monofrequent signal that is emitted by a small portable transmitter placed inside the bore (Pilot Tone). The frequency is selected such that it is located outside of the frequency band of the actual MR readout experiment but well within the bandwidth of the radiofrequency receiver, that is, the oversampling area. Temporal variations of the detected signal indicate motion. After extraction of the signal from the raw data, principal component analysis was used to identify respiratory motion. The approach and potential applications during MR and PET/MR examinations that rely on a continuous respiratory signal were validated with an anthropomorphic, PET/MR-compatible motion phantom as well as in a volunteer study. Results: Respiratory motion detection and correction were presented for MR and PET data in phantom and volunteer studies. The Pilot Tone successfully recovered the ground-truth respiratory signal provided by the phantom. Conclusions: The presented method provides reliable respiratory motion tracking during arbitrary imaging sequences throughout a full PET/MR study. All results can directly be transferred to MR-only applications as well. … (more)
- Is Part Of:
- Investigative radiology. Volume 55:Issue 3(2020)
- Journal:
- Investigative radiology
- Issue:
- Volume 55:Issue 3(2020)
- Issue Display:
- Volume 55, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 55
- Issue:
- 3
- Issue Sort Value:
- 2020-0055-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-03
- Subjects:
- motion detection -- motion correction -- free-breathing examinations -- PET/MR -- MR
Diagnosis, Radioscopic -- Periodicals
Radiology, Medical -- Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/investigativeradiology/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RLI.0000000000000619 ↗
- Languages:
- English
- ISSNs:
- 0020-9996
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4560.350000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: