Modeling the diffusion‐weighted imaging signal for breast lesions in the b = 200 to 3000 s/mm2 range: quality of fit and classification accuracy for different representations. Issue 2 (23rd January 2020)
- Record Type:
- Journal Article
- Title:
- Modeling the diffusion‐weighted imaging signal for breast lesions in the b = 200 to 3000 s/mm2 range: quality of fit and classification accuracy for different representations. Issue 2 (23rd January 2020)
- Main Title:
- Modeling the diffusion‐weighted imaging signal for breast lesions in the b = 200 to 3000 s/mm2 range: quality of fit and classification accuracy for different representations
- Authors:
- Vidić, Igor
Egnell, Liv
Jerome, Neil P.
White, Nathan S.
Karunamuni, Roshan
Rakow‐Penner, Rebecca
Dale, Anders M.
Bathen, Tone F.
Goa, Pål Erik - Abstract:
- Abstract : Purpose: To evaluate different non‐Gaussian representations for the diffusion‐weighted imaging (DWI) signal in the b‐value range 200 to 3000 s/mm 2 in benign and malignant breast lesions. Methods: Forty‐three patients diagnosed with benign (n = 18) or malignant (n = 25) tumors of the breast underwent DWI (b‐values 200, 600, 1200, 1800, 2400, and 3000 s/mm 2 ). Six different representations were fit to the average signal from regions of interest (ROIs) at different b‐value ranges. Quality of fit was assessed by the corrected Akaike information criterion (AICc), and the Friedman test was used for assessing representation ranks. The area under the curve (AUC) of receiver operating characteristic curves were used to evaluate the power of derived parameters to differentiate between malignant and benign lesions. The lesion ROI was divided in central and peripheral parts to assess potential effect of heterogeneity. Sensitivity to noise‐floor correction was also evaluated. Results: The Padé exponent was ranked as the best based on AICc, whereas 3 models (kurtosis, fractional, and biexponential) achieved the highest AUC = 0.99 for lesion differentiation. The monoexponential model at bmax = 600 s/mm 2 already provides AUC = 0.96, with considerably shorter acquisition time and simpler analysis. Significant differences between central and peripheral parts of lesions were found in malignant lesions. The mono‐ and biexponential models were most stable against varying degrees ofAbstract : Purpose: To evaluate different non‐Gaussian representations for the diffusion‐weighted imaging (DWI) signal in the b‐value range 200 to 3000 s/mm 2 in benign and malignant breast lesions. Methods: Forty‐three patients diagnosed with benign (n = 18) or malignant (n = 25) tumors of the breast underwent DWI (b‐values 200, 600, 1200, 1800, 2400, and 3000 s/mm 2 ). Six different representations were fit to the average signal from regions of interest (ROIs) at different b‐value ranges. Quality of fit was assessed by the corrected Akaike information criterion (AICc), and the Friedman test was used for assessing representation ranks. The area under the curve (AUC) of receiver operating characteristic curves were used to evaluate the power of derived parameters to differentiate between malignant and benign lesions. The lesion ROI was divided in central and peripheral parts to assess potential effect of heterogeneity. Sensitivity to noise‐floor correction was also evaluated. Results: The Padé exponent was ranked as the best based on AICc, whereas 3 models (kurtosis, fractional, and biexponential) achieved the highest AUC = 0.99 for lesion differentiation. The monoexponential model at bmax = 600 s/mm 2 already provides AUC = 0.96, with considerably shorter acquisition time and simpler analysis. Significant differences between central and peripheral parts of lesions were found in malignant lesions. The mono‐ and biexponential models were most stable against varying degrees of noise‐floor correction. Conclusion: Non‐Gaussian representations are required for fitting of the DWI curve at high b‐values in breast lesions. However, the added clinical value from the high b‐value data for differentiation of benign and malignant lesions is not clear. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 84:Issue 2(2020)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 84:Issue 2(2020)
- Issue Display:
- Volume 84, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 84
- Issue:
- 2
- Issue Sort Value:
- 2020-0084-0002-0000
- Page Start:
- 1011
- Page End:
- 1023
- Publication Date:
- 2020-01-23
- Subjects:
- biexponential model -- breast MR -- diffusion‐weighted MRI -- DKI -- fractional order calculus -- Padé exponent -- statistical diffusion model -- stretched exponential
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28161 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18710.xml