Dosimetric evaluation of synthetic CT for head and neck radiotherapy generated by a patch‐based three‐dimensional convolutional neural network. Issue 9 (9th July 2019)
- Record Type:
- Journal Article
- Title:
- Dosimetric evaluation of synthetic CT for head and neck radiotherapy generated by a patch‐based three‐dimensional convolutional neural network. Issue 9 (9th July 2019)
- Main Title:
- Dosimetric evaluation of synthetic CT for head and neck radiotherapy generated by a patch‐based three‐dimensional convolutional neural network
- Authors:
- Dinkla, Anna M.
Florkow, Mateusz C.
Maspero, Matteo
Savenije, Mark H. F.
Zijlstra, Frank
Doornaert, Patricia A. H.
van Stralen, Marijn
Philippens, Marielle E. P.
van den Berg, Cornelis A. T.
Seevinck, Peter R. - Abstract:
- Abstract : Purpose: To develop and evaluate a patch‐based convolutional neural network (CNN) to generate synthetic computed tomography (sCT) images for magnetic resonance (MR)‐only workflow for radiotherapy of head and neck tumors. A patch‐based deep learning method was chosen to improve robustness to abnormal anatomies caused by large tumors, surgical excisions, or dental artifacts. In this study, we evaluate whether the generated sCT images enable accurate MR‐based dose calculations in the head and neck region. Methods: We conducted a retrospective study on 34 patients with head and neck cancer who underwent both CT and MR imaging for radiotherapy treatment planning. To generate the sCTs, a large field‐of‐view T2‐weighted Turbo Spin Echo MR sequence was used from the clinical protocol for multiple types of head and neck tumors. To align images as well as possible on a voxel‐wise level, CT scans were nonrigidly registered to the MR (CTreg ). The CNN was based on a U‐net architecture and consisted of 14 layers with 3 × 3 × 3 filters. Patches of 48 × 48 × 48 were randomly extracted and fed into the training. sCTs were created for all patients using threefold cross validation. For each patient, the clinical CT‐based treatment plan was recalculated on sCT using Monaco TPS (Elekta). We evaluated mean absolute error (MAE) and mean error (ME) within the body contours and dice scores in air and bone mask. Also, dose differences and gamma pass rates between CT‐ and sCT‐based plansAbstract : Purpose: To develop and evaluate a patch‐based convolutional neural network (CNN) to generate synthetic computed tomography (sCT) images for magnetic resonance (MR)‐only workflow for radiotherapy of head and neck tumors. A patch‐based deep learning method was chosen to improve robustness to abnormal anatomies caused by large tumors, surgical excisions, or dental artifacts. In this study, we evaluate whether the generated sCT images enable accurate MR‐based dose calculations in the head and neck region. Methods: We conducted a retrospective study on 34 patients with head and neck cancer who underwent both CT and MR imaging for radiotherapy treatment planning. To generate the sCTs, a large field‐of‐view T2‐weighted Turbo Spin Echo MR sequence was used from the clinical protocol for multiple types of head and neck tumors. To align images as well as possible on a voxel‐wise level, CT scans were nonrigidly registered to the MR (CTreg ). The CNN was based on a U‐net architecture and consisted of 14 layers with 3 × 3 × 3 filters. Patches of 48 × 48 × 48 were randomly extracted and fed into the training. sCTs were created for all patients using threefold cross validation. For each patient, the clinical CT‐based treatment plan was recalculated on sCT using Monaco TPS (Elekta). We evaluated mean absolute error (MAE) and mean error (ME) within the body contours and dice scores in air and bone mask. Also, dose differences and gamma pass rates between CT‐ and sCT‐based plans inside the body contours were calculated. Results: sCT generation took 4 min per patient. The MAE over the patient population of the sCT within the intersection of body contours was 75 ± 9 Hounsfield Units (HU) (±1 SD), and the ME was 9 ± 11 HU. Dice scores of the air and bone masks (CTreg vs sCT) were 0.79 ± 0.08 and 0.70 ± 0.07, respectively. Dosimetric analysis showed mean deviations of −0.03% ± 0.05% for dose within the body contours and −0.07% ± 0.22% inside the >90% dose volume. Dental artifacts obscuring the CT could be circumvented in the sCT by the CNN‐based approach in combination with Turbo Spin Echo (TSE) magnetic resonance imaging (MRI) sequence that typically is less prone to susceptibility artifacts. Conclusions: The presented CNN generated sCTs from conventional MR images without adding scan time to the acquisition. Dosimetric evaluation suggests that dose calculations performed on the sCTs are accurate, and can therefore be used for MR‐only radiotherapy treatment planning of the head and neck. … (more)
- Is Part Of:
- Medical physics. Volume 46:Issue 9(2019)
- Journal:
- Medical physics
- Issue:
- Volume 46:Issue 9(2019)
- Issue Display:
- Volume 46, Issue 9 (2019)
- Year:
- 2019
- Volume:
- 46
- Issue:
- 9
- Issue Sort Value:
- 2019-0046-0009-0000
- Page Start:
- 4095
- Page End:
- 4104
- Publication Date:
- 2019-07-09
- Subjects:
- deep learning -- head and neck cancer -- MR‐guided therapy -- MR‐only radiotherapy -- synthetic CT
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.13663 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18717.xml