SPARE: Sparse‐view reconstruction challenge for 4D cone‐beam CT from a 1‐min scan. Issue 9 (19th July 2019)
- Record Type:
- Journal Article
- Title:
- SPARE: Sparse‐view reconstruction challenge for 4D cone‐beam CT from a 1‐min scan. Issue 9 (19th July 2019)
- Main Title:
- SPARE: Sparse‐view reconstruction challenge for 4D cone‐beam CT from a 1‐min scan
- Authors:
- Shieh, Chun‐Chien
Gonzalez, Yesenia
Li, Bin
Jia, Xun
Rit, Simon
Mory, Cyril
Riblett, Matthew
Hugo, Geoffrey
Zhang, Yawei
Jiang, Zhuoran
Liu, Xiaoning
Ren, Lei
Keall, Paul - Abstract:
- Abstract : Purpose: Currently, four‐dimensional (4D) cone‐beam computed tomography (CBCT) requires a 3–4 min full‐fan scan to ensure usable image quality. Recent advancements in sparse‐view 4D‐CBCT reconstruction have opened the possibility to reduce scan time and dose. The aim of this study is to provide a common framework for systematically evaluating algorithms for 4D‐CBCT reconstruction from a 1‐min scan. Using this framework, the AAPM‐sponsored SPARE Challenge was conducted in 2018 to identify and compare state‐of‐the‐art algorithms. Methods: A clinically realistic CBCT dataset was simulated using patient CT volumes from the 4D‐Lung database. The selected patients had multiple 4D‐CT sessions, where the first 4D‐CT was used as the prior CT, and the rest were used as the ground truth volumes for simulating CBCT projections. A GPU‐based Monte Carlo tool was used to simulate the primary, scatter, and quantum noise signals. A total of 32 CBCT scans of nine patients were generated. Additional qualitative analysis was performed on a clinical Varian and clinical Elekta dataset to validate the simulation study. Participants were blinded from the ground truth, and were given 3 months to apply their reconstruction algorithms to the projection data. The submitted reconstructions were analyzed in terms of root‐mean‐squared‐error (RMSE) and structural similarity index (SSIM) with the ground truth within four different region‐of‐interests (ROI) — patient body, lungs, planning targetAbstract : Purpose: Currently, four‐dimensional (4D) cone‐beam computed tomography (CBCT) requires a 3–4 min full‐fan scan to ensure usable image quality. Recent advancements in sparse‐view 4D‐CBCT reconstruction have opened the possibility to reduce scan time and dose. The aim of this study is to provide a common framework for systematically evaluating algorithms for 4D‐CBCT reconstruction from a 1‐min scan. Using this framework, the AAPM‐sponsored SPARE Challenge was conducted in 2018 to identify and compare state‐of‐the‐art algorithms. Methods: A clinically realistic CBCT dataset was simulated using patient CT volumes from the 4D‐Lung database. The selected patients had multiple 4D‐CT sessions, where the first 4D‐CT was used as the prior CT, and the rest were used as the ground truth volumes for simulating CBCT projections. A GPU‐based Monte Carlo tool was used to simulate the primary, scatter, and quantum noise signals. A total of 32 CBCT scans of nine patients were generated. Additional qualitative analysis was performed on a clinical Varian and clinical Elekta dataset to validate the simulation study. Participants were blinded from the ground truth, and were given 3 months to apply their reconstruction algorithms to the projection data. The submitted reconstructions were analyzed in terms of root‐mean‐squared‐error (RMSE) and structural similarity index (SSIM) with the ground truth within four different region‐of‐interests (ROI) — patient body, lungs, planning target volume (PTV), and bony anatomy. Geometric accuracy was quantified as the alignment error of the PTV. Results: Twenty teams participated in the challenge, with five teams completing the challenge. Techniques involved in the five methods included iterative optimization, motion‐compensation, and deformation of the prior 4D‐CT. All five methods rendered significant reduction in noise and streaking artifacts when compared to the conventional Feldkamp–Davis–Kress (FDK) algorithm. The RMS of the three‐dimensional (3D) target registration error of the five methods ranged from 1.79 to 3.00 mm. Qualitative observations from the Varian and Elekta datasets mostly concur with those from the simulation dataset. Each of the methods was found to have its own strengths and weaknesses. Overall, the MA‐ROOSTER method, which utilizes a 4D‐CT motion model for temporal regularization, had the best and most consistent image quality and accuracy. Conclusion: The SPARE Challenge represents the first framework for systematically evaluating state‐of‐the‐art algorithms for 4D‐CBCT reconstruction from a 1‐min scan. Results suggest the potential for reducing scan time and dose for 4D‐CBCT. The challenge dataset and analysis framework are publicly available for benchmarking future reconstruction algorithms. … (more)
- Is Part Of:
- Medical physics. Volume 46:Issue 9(2019)
- Journal:
- Medical physics
- Issue:
- Volume 46:Issue 9(2019)
- Issue Display:
- Volume 46, Issue 9 (2019)
- Year:
- 2019
- Volume:
- 46
- Issue:
- 9
- Issue Sort Value:
- 2019-0046-0009-0000
- Page Start:
- 3799
- Page End:
- 3811
- Publication Date:
- 2019-07-19
- Subjects:
- 4D‐CBCT -- grand challenge -- image reconstruction
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.13687 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18717.xml