Evaluating HIFU‐mediated local drug release using thermal strain imaging: Phantom and preliminary in‐vivo studies. Issue 9 (5th August 2019)
- Record Type:
- Journal Article
- Title:
- Evaluating HIFU‐mediated local drug release using thermal strain imaging: Phantom and preliminary in‐vivo studies. Issue 9 (5th August 2019)
- Main Title:
- Evaluating HIFU‐mediated local drug release using thermal strain imaging: Phantom and preliminary in‐vivo studies
- Authors:
- Lee, Fu‐Feng
He, Qiong
Gao, Jing
Pan, Anni
Sun, Suhui
Liang, Xiaolong
Luo, Jianwen - Abstract:
- Abstract : Purpose: High‐intensity focused ultrasound (HIFU)‐mediated drug release becomes a promising therapeutic technique for treatment of cancer, which has merits of deep penetration, noninvasive approach and nonionizing radiation. However, conventional thermocouple‐based approach for treatment monitoring would encounter big challenges such as the viscous heating artifact and difficulty in monitoring in the deep region. In this study, we develop an effective method based on thermal strain imaging (TSI) for the evaluation of HIFU‐mediated drug release. Methods: Both phantom experiments and preliminary animal experiments were performed to investigate the feasibility of the proposed approach. Doxorubicin (DOX)‐loaded cerasomes (HIFU and temperature‐sensitive cerasomes, HTSCs) were prepared. In the phantom experiments, the HTSC solution is contained inside a cylindrical chamber within a tissue‐mimicking phantom. In the animal experiments, the HTSCs are intravenously injected into tumor‐bearing mice. An HIFU transducer is used to trigger DOX release from the HTSCs within the phantom or mice, and TSI is performed during HIFU heating. In the phantom experiments, the accuracy of temperature estimation using TSI is validated by measuring with a thermocouple. In animal experiments, the spatial consistency between the distribution of DOX released within the tumor and the location of the heating region estimated by TSI is validated using a spectrofluorophotometer. Results: In theAbstract : Purpose: High‐intensity focused ultrasound (HIFU)‐mediated drug release becomes a promising therapeutic technique for treatment of cancer, which has merits of deep penetration, noninvasive approach and nonionizing radiation. However, conventional thermocouple‐based approach for treatment monitoring would encounter big challenges such as the viscous heating artifact and difficulty in monitoring in the deep region. In this study, we develop an effective method based on thermal strain imaging (TSI) for the evaluation of HIFU‐mediated drug release. Methods: Both phantom experiments and preliminary animal experiments were performed to investigate the feasibility of the proposed approach. Doxorubicin (DOX)‐loaded cerasomes (HIFU and temperature‐sensitive cerasomes, HTSCs) were prepared. In the phantom experiments, the HTSC solution is contained inside a cylindrical chamber within a tissue‐mimicking phantom. In the animal experiments, the HTSCs are intravenously injected into tumor‐bearing mice. An HIFU transducer is used to trigger DOX release from the HTSCs within the phantom or mice, and TSI is performed during HIFU heating. In the phantom experiments, the accuracy of temperature estimation using TSI is validated by measuring with a thermocouple. In animal experiments, the spatial consistency between the distribution of DOX released within the tumor and the location of the heating region estimated by TSI is validated using a spectrofluorophotometer. Results: In the phantom experiments, the HTSCs show a burst release of DOX when the temperature of the HTSC solution estimated by TSI reaches about 42°C, which is in agreement with the condition for drug release from the HTSCs. The temperature estimation using TSI has high accuracy with error below 2.5%. In animal experiments, fluorescence imaging of the tumor validates that the heating region of HIFU could be localized by the low‐strain region of TSI. Conclusion: The present framework demonstrates a reliable and effective solution to the evaluation of HIFU‐mediated local drug delivery. … (more)
- Is Part Of:
- Medical physics. Volume 46:Issue 9(2019)
- Journal:
- Medical physics
- Issue:
- Volume 46:Issue 9(2019)
- Issue Display:
- Volume 46, Issue 9 (2019)
- Year:
- 2019
- Volume:
- 46
- Issue:
- 9
- Issue Sort Value:
- 2019-0046-0009-0000
- Page Start:
- 3864
- Page End:
- 3876
- Publication Date:
- 2019-08-05
- Subjects:
- drug release -- high‐intensity focused ultrasound -- thermal‐sensitive cerasomes -- thermal strain imaging -- ultrasound imaging
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.13719 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18717.xml